                      Site Access and Driveways
               27.    A sealed access driveway must be provided from Henderson Street to all parking and
                      manoeuvring areas of the development. The access must be generally in accordance with
                      the approved plans.
                      Car Parking
               28.    A minimum of 5 covered car parking spaces must be provided and made available for
                      carparking at all times. The car parking must be generally in accordance with the approved
                      plans and include in particular dimensions, crossfalls and gradients in accordance with
                      Australian Standard AS/NZS2890.1:2004 - Parking Facilities.
               29.    All vehicles must enter and exit the site in a forward gear.
               30.    Directional signage must be provided to direct visitors to the car parking spaces provided in
                      the basement.
                      Pedestrian and Bicycle Facilities
               31.    Pedestrian and bicycle facilities must be provided for the development. The works must
                      include widening of the existing footpath to 2 metres.
                      Condition 31 is imposed pursuant to s128 of the Planning Act 2016 being necessary trunk
                      infrastructure identified by Council’s LGIP to service the development.
                      Stormwater Drainage
               32.    The site must be provided with a stormwater drainage system connecting to a lawful point of
                      discharge. The works must be generally in accordance with the approved plans.
                      Services
               33.    Reticulated electricity and telecommunication services must be provided to each lot/unit in
                      accordance with the standards and requirements of the relevant service provider.
               34.    Unless otherwise stipulated by telecommunications legislation at the time of construction, the
                      development must be provided with all necessary conduits, pits and pipes to accommodate
                      the future connection of optic fibre technology telecommunications.
               35.    Certification must be submitted to Council from all relevant service providers (Energex, NBN
                      and Unitywater) which certifies that the development has met the requirements of this
                      Decision Notice and all applicable legislation at the time of construction.
                      Easements
               36.    Unless otherwise agreed in writing by the relevant service provider, any public or third party
                      infrastructure located on the subject site must be placed within an easement registered
                      against the title of the property.
               37.    All easements must be designed in accordance with the planning scheme and granted at no
                      cost to the Grantee. Where the Grantee is Council or a service authority, the easement
                      documentation must be in accordance with the Grantee’s standard easement terms. Draft
                      easement documentation must be submitted to Council for endorsement.
               38.    All works must be kept clear of any existing or proposed easements on the subject land,
                      unless agreed otherwise in writing by the Grantee.
                      Earthworks and Retaining Walls
               39.    All earthworks and associated retaining structures/batters/anchors, both above and below
                      ground level, both temporary and permanent, must be contained entirely within the subject
                      site unless written permission from the respective landowner(s) is provided to Council.
               40.    All retaining walls must be designed and constructed in accordance with the planning scheme
                      and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
                      are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
                      safety fence.

                                                                                                     Page 17 of 28

Document Set ID: 22322758
Version: 7, Version Date: 22/08/2023

Used in these records

About this file

File size
6.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - Planning MCU22 0145 [As Published].pdf · 6.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.