Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES
unit 8/ 283-285 weyba road, noosaville 4566 (VERANO) TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
7700
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
3700 4000
GRADE F14 & MINIMUM JOINT GROUP J2.
100 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
200 3600 3600 200
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
100 SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
200 5300 1900 200 ACCORDANCE WITH AS 1684.2 2010
01 of 03 100 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
200 4200 3000 200 TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
elevation C
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
03 of 05 elevation B
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
200
9. BUILDER AND TRADES ARE TO CONFIRM ALL
01
1100
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
proposed skylight SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
bed AS NO RESPONSIBILITY WILL BE TAKEN AFTER
3100
CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE
existing
roof over
kit CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
100
3660.1.2000
900
100
DOMESTIC SMOKE ALARMS
windows over to be replaced 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
bath
2100
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
12500
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
100
proposed mezzanine
11400
AND INTERCOM SYSTEMS.
elevation B
3. DEVICES MUST BE INTERCONNECTED AND HARD
ens
1500
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
600
lounge/living BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
master SUBJECT TO CONFIRMATION UPON SITE MEASURE
3600
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
200
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
elevation D
DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
03 of 05 01 balcony CONFIRMED AT TIME OF ROOFING CONSTRUCTION
existing fixed glass AND COMPLIANCE
(propose opening glazing) proposed mezzanine
proposed skylight
4866
3645
existing floor
kit lounge/living
Section 1
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: NEIL AND LOUISE BUILDER: PAUL ROBERTS MANDY'S DESIGN & DRAFTING SHEET: 1 of 3 DATE: ISSUE NO:
RENOVATION FINLAYSON PH: 0403 209 203 PH: 0409 278 879 PH: 0403 481 474 SCALE: 1:100 12 AUG 2020 NL2020-D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20200228 - Change Application Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.4 MB (small file)
- File type
No other editions are linked here.