                                                                                                                                                                                                                                                                GENERAL NOTES


unit 8/ 283-285 weyba road, noosaville 4566 (VERANO)                                                                                                                                                                                                            TIMBER FRAMING AND CONSTRUCTION
                                                                                                                                                                                                                                                                1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
                                                                                                                                                                                                                                                                THE AUSTRALIAN DOMESTIC BUILDING CODE.
                                                                                                                                                                                                                                                                2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
                                                                                                                                                                                                                                                                AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
                                                                                                                                                                                                                                                                3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
                                                                                                    03 of 03                                                                                                     03 of 03                                       MGP 10/MGP12
                                                                                                                                                                                                                                                                4.HARDWOOD FRAMING TO BE MINIMUM STRESS
                                                                                                                                                                                                                                                                GRADE F14 & MINIMUM JOINT GROUP J2.
                                                                                                 Elevation 1 - a 02                                                                                         Elevation 1 - a                                     5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
                                                                                                                                                                                                                              02                                6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
                                                                                                 renovate                                                                                                                                                       SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
                                                                                                 existing kitchen                                                                                                                                               ACCORDANCE WITH AS 1684.2 2010
                                                                                                                                                                                                             roof below
                                                                                                                                                                                                                                                                7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
                                                                                                                                                                                                                                                                TABLES WHERE OTHER BRANDS ARE USED, SIZES TO

                                                                                                           tube skylight
                                                                                                                                              bed                                                                                                               BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
                                                                                                                                                                                                                                                                8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
                                                                                                                                                                                                                                                                9. BUILDER AND TRADES ARE TO CONFIRM ALL
                                                                                                                      kit                                                                                                                                       MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
                                                                                                                                                                                                                            skylight                            SETOUT AND ORDERING OF MATERIALS
                                                                                                                                                                                                                                                                10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
                                                                                                                                                               renovate existing l'dry
                                                                                                                                                  l'dry                                                                                                         AS NO RESPONSIBILITY WILL BE TAKEN AFTER
                                                                                                                                                                                                                                                                CONSTRUCTION HAS COMMENCED
                                                                                                                                                               renovate existing bath                                                                           11. ALL TRADES ARE TO CONFORM WITH THE
                                                                                                                                                                                                             1230 4 panel louvres 120blades
                                                                                                                                                                                                                                                                CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
                                                                                                                                                                                                             (size to be confirmed on site)

                                                                                 3
                                                                                                                                               bath                 3                            3                                                    3
                                                                                                                                                                                                                                                                HER OWN WORK
                                                                                                                                                                                                                                                                12. TERMITE PROTECTION TO BE PROVIDED AS PER AS




                                                                                                                                                                                                     3000
                                                                                                                                                                                                               VWXG\mezzanine                                 3660.1.2000

                                                                                                                                                                                                            DN                                                  DOMESTIC SMOKE ALARMS
                                                                                                                                                                                                                                                                1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
                                                                                proposed
                                                                                spiral stairs         UP
                                                                                                               proposed mezzanine over         ens             renovate existing ensuite                                         glass balustrading
                                                                                                                                                                                                                                        (one way)
                                                                                                                                                                                                                                                                WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
                                                                                                                                                                                                                                                                WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
                                                                                as selected                     balustrading as required                                                                                                                        REGULATION 2016
                                                                                                                                                                                                                                4200                            2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
                                                                                by owner
                                                                                                                                                                                                                                                                WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
                                                                                                                                                                                                                                4200                            AND INTERCOM SYSTEMS.
                                                                                                                                                                                                                                                                3. DEVICES MUST BE INTERCONNECTED AND HARD
                                                                                                                                                                                                                                                                WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
                                                                                                            lounge/living                                                                                                                                       REMOVED FROM DEVICE
                                                                                                                                             master                                                                                                             4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
                                                                                                                                                                                                                                                                BEDROOMS TO EXISTING RESIDENCES
                                                                                                                                                                                                                                                                S INDICATES THE LOCATION OF WIRED SMOKE ALARMS

                                                                                                                                                                                                                                                                GLAZING
                                                                                                                                                                                                                                                                1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
                                                                                                                                                                                                                                                                SUBJECT TO CONFIRMATION UPON SITE MEASURE
                                                                                                                 02                                                                                                                                             2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
                                                                                                                                                                                                                                                                TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
                                                                                                                                                                                                                              02                                PRIVACY OPTIONS

                                                                                                                                                                                                                                                                ELECTRICAL AND ENERGY EFFICIENCY
                                                                                                                                                                                                                                                                1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
                                                                                                                                                                                                                                                                AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
                                                                                                                                                                                                                                                                INDICATIVE ONLY

                                                                                                                                                                                                                                                                DOWNPIPES
                                                                                                                                                                                                                                                                ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
                                                                                                                                                                                                                                                                CONFIRMED AT TIME OF ROOFING CONSTRUCTION
                                                                                                                                                                                                                                                                AND COMPLIANCE

                                                                                            Proposed Floor                                                                                                  Upper Floor




                                                                                                                                                                                                                                                                                                           proposed floor
                                                                                                                                                                                                                                                                                     N




                                                       NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC

                                                       PROPOSED:                                CLIENT: NEIL AND LOUISE                                           BUILDER: PAUL ROBERTS                              MANDY'S DESIGN & DRAFTING SHEET: 2 of 3 DATE:                     ISSUE NO:
                                                       RENOVATION                               FINLAYSON PH: 0403 209 203                                        PH: 0409 278 879                                   PH: 0403 481 474          SCALE: 1:100 12 AUG 2020                NL2020-D
                                                       NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION                       NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
                                                       WITH ENGINEERS DRAWINGS                                              RESPONSIBILITY LIES THERE WITH

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

20200228 - Change Application Plans.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.