GENERAL NOTES
unit 8/ 283-285 weyba road, noosaville 4566 (VERANO) TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
new window height and size to be 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
1200
confirmed on site 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
sill height
minimum
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
580
skylight 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
Elevation 1 - a AS NO RESPONSIBILITY WILL BE TAKEN AFTER
CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
one way glass DOMESTIC SMOKE ALARMS
1692
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
proposed skylight
1000
mezzanine floor depth as per engineers design
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
minimal preferred REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
3645
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
floor joist system 3. DEVICES MUST BE INTERCONNECTED AND HARD
as per engineers WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
design REMOVED FROM DEVICE
kit lounge/living 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
support to side walls S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
Section 2 as per engineers design
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
mezzanine
existing block fire wall
INDICATIVE ONLY
300
DOWNPIPES
proposed elevations
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
2400
AND COMPLIANCE
adjacent unit
Section 3
3D View 4
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: NEIL AND LOUISE BUILDER: PAUL ROBERTS MANDY'S DESIGN & DRAFTING SHEET: 3 of 3 DATE: ISSUE NO:
RENOVATION FINLAYSON PH: 0403 209 203 PH: 0409 278 879 PH: 0403 481 474 SCALE: 1:100 12 AUG 2020 NL2020-D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20200228 - Change Application Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.4 MB (small file)
- File type
No other editions are linked here.