Original source · versioned page text
response to information request - 9 Bottlebrush
Attached to the e-mail Response to RFI - 9 Bottlebrush Avenue Noosa Heads - MCU21/0133.
29 September 2021 Patrick Murphy Noosa Council [email protected] RE: Response to Information Request – MCU21/0133 & OPW21/0220 – 9 Bottlebrush Ave, Noosa Heads Council issued a further information request on 2 September 2021. The applicant provides the following additional information in response to the items: 1. Provide amended plans that include: 1.1. The longitudinal section extending to the centreline of the road formation. 1.2. The plans with the footpath section located where pedestrians could reasonably cross to the existing path in the frontage of the adjoining property. 1.3. The footpath section with a consistent width on the relevant plans (desirably 2m, 1.5m minimum). 1.4. Additional sections within the road reserve which clearly indicate the transitions to the adjacent verge areas which do not create trip or fall hazards. 1.5. Please note that Council does not support private retaining structures in the road reserve. 1.6. The depths of the existing services in the road reserve determined by potholing. If it is apparent that services may need to be altered provided written approval from the relevant service provider. 2. Provide amended plans that demonstrate that all spaces are accessible for a B99 vehicle to enter the space in a forward gear, reverse from the space and exit the site in a forward gear in a total of 3 movements. 3. Provide a plan that demonstrates that vehicles can reverse from the visitor space and exit the site in a forward gear when the garage door is closed. 4. Indicate on the plan the extent of the door and the potential impacts on the swept paths for carspaces 2 & 3. 5. Provide additional comment in regard to: 5.1. The discharge rate at the outlet point in the kerb and channel (Council’s maximum is 25l/sec). Council requires the discharge to not extend into the traffic lane and create a traffic hazard so if the discharge is greater than 25l/sec provide justification for the proposed rate 5.2. There does not appear to be any measures/structures to address overland flows adjacent to the southern boundary. It is noted that the proposed bin store extends to the property boundary and has the potential to block/redirect overland flows.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.