PROJECT NO. 23/8894                                                 24th JULY 2023
NORTH COAST GEOMECHANICAL CONSULTANTS
                          1/36 Maud Street
          MAROOCHYDORE QLD 4558
                                                 Phone 07 5443 2988
                                                      Fax 07 5443 5157
                                 Email: [email protected]


             ON-SITE DOMESTIC WASTEWATER
                   EVALUATION REPORT

                      PROPOSED RESIDENCE AT
                        193 SANKEYS ROAD,
                              FEDERAL




                              FOR LACHLAN ROBINS


TESTING AUTHORITY:              CIVIL QUALITY ASSURANCE PTY. LTD.
                                P.O. BOX 1225, NAMBOUR, QLD. 4560

8894-193 SANKEYS RD-FEDERAL        Page 1 of 13                       24/07/2023
Full text of the other 12 pages

Page 2

PROJECT NO. 23/8894                                                              24th JULY 2023


1.0    INTRODUCTION: The Site Inspection and Field Testing to determine soil types
       and characteristics were carried out by Civil Quality Assurance Pty.Ltd.
       This report refers to their findings and results to determine a suitable method and size
       of domestic wastewater application area from a proposed 4-bedroom residential
       dwelling.


2.0    SITE: The allotment is situated off the western side of Sankeys Road, FEDERAL.
       It is a large heavily timbered allotment described as Lot.6 RP216727 with an area of
       6.041 hectares. Refer locality on front cover of this report. A wastewater application
       area was selected on the northern western side of the proposed building site.
       The area’s natural land surface falls to the south west at about 18%. The area is
       heavily treed bushland and well grassed.
       Testing was carried out over the proposed wastewater disposal area to determine soil
       types and characteristics of the existing soils for the purpose of on-site domestic
       wastewater disposal.    Soil Classifications and Descriptions were carried out in
       accordance with A.S. 1547:2012 “On-Site Domestic Wastewater Management” and
       the “On-Site Sewerage Code” published by The Department of Natural Resources.
       Test Locations are shown on the attached Site Plan.


3.0    SUB-SURFACE INVESTIGATIONS:                     Boreholes carried out revealed silty clay
       surface soils of medium to high plasticity overlaying shallow highly weathered
       shaley siltstone. Soils classified in accordance with Table 5.1 of A.S. 1547:2012
       were given a general Soil Category 5 (Massive Structure). Borelogs showing the soil
       profile are attached.
       Percolation Testing measures the soil’s water absorption capabilities. The testing
       was carried out in accordance with A.S. 1547:2012, Appendix G, using 100mm
       diameter test holes to a depth of 450mm. The tests were carried out in several
       positions on the site and the results are shown on the attached Desktop Analysis.




8894-193 SANKEYS RD-FEDERAL             Page 2 of 13                              24/07/2023

Page 3

PROJECT NO. 23/8894                                                            24th JULY 2023


4.0    HYDRAULIC FLOWS AND RECOMMENDED DISPOSAL SYSTEMS:
       Calculations in accordance with Appendix 4.2D of A.S.1547:2012, using the
       proposed 4-bedroom residence, supplied by on site storage tank water supply as
       having 6 equivalent person occupancy rating. A typical wastewater flow design
       allowance from Table H1 of AS1547 of 120 litres/person per day was used to
       calculate a daily effluent sullage flow figure of 720 litres per day or 5,040 litres per
       week using standard water fixtures.
       We recommend the use of Standard Water Reduction Fixtures. These fixtures should
       include: -     a) Dual Flush 11 litre/5.5 litre WC's.
                      b) Shower Flow Restrictors.
                      c) Aerator Faucets.
                      d) Water Conserving Washing Machines.


       Due to the poorly-draining Category 5 silty soils and the presence of a shallow
       weathered siltstone, the steep slope and the close proximity of nearby gully
       (watercourse),, we recommend all domestic effluent be treated to a minimum
       Secondary Quality as described in Clause 11.8.4 of the “On-Site Sewerage Code”
       and discharged into a shallow sub-surface irrigation area, utilizing the
       evapotranspiration effects of the surface soils, plants, the sun and wind. Treatment
       shall be by On-Site Treatment Plant with model or type specification approval,
       installed, operated and maintained in accordance with the conditions of model or type
       specification approval. Many approved Secondary treatment wastewater systems are
       available these days and their particular irrigation methods may vary slightly.


       We recommend a suitable wastewater land application area could be a Shallow Sub-
       Surface Irrigation area consisting of rows of shallow buried geofabric wrapped
       seepage pipes along the contour surrounded by 10-15mm gravel connected by
       manifold and turf valves from the treatment tank. Each shallow pipe should have its
       own isolation valve and cleanout end capping.




8894-193 SANKEYS RD-FEDERAL             Page 3 of 13                             24/07/2023

Page 4

PROJECT NO. 23/8894                                                         24th JULY 2023


4.0    HYDRAULIC FLOWS AND RECOMMENDED DISPOSAL SYSTEMS
                                                                                 (Cont.):
       Calculations of wastewater loadings have resulted in a minimum area of 240m2 of
       Disposal Area required for the residence proposed. An indicative area has been
       shown on the Site Plan.
       Setback distances are calculated to prevent any viruses present within sewage
       effluent travelling through the soil, contaminating areas that may come in contact
       with human habitation and into streams.
       The “On-Site Sewerage Code” by the Department of Natural Resources recommends
       a minimum setback to any watercourse or dam for the location of Secondary Treated
       Wastewater Application Areas are to be a minimum of 30 metres.
       All surface water and seepage water up slope of the disposal area shall be diverted
       around the area. All disposal areas shall be setback a minimum 4.0 metres from
       boundaries on the downhill side, and 2.0 metres from all other boundaries. Buildings
       shall be a minimum of 15.0 metres from the wastewater application area.
       Grass cover and vegetation should be maintained around the area as well as good
       sunlight exposure to maximise evapotranspiration.


       To ensure optimum performance of disposal areas, adequate maintenance of systems
       is essential.   They should be installed by approved and licensed plumbers and
       maintained at regular scheduled intervals.


5.0    SUMMARY:               The Treatment System and Land Application Area is considered
       suitable for proposed domestic On-Site Effluent Disposal provided the setback
       guidelines set out in this report are followed.
       Should the client have any queries in relation to the information contained in this
       report, this office should be contacted.




       K.N. CROCKER                   (M.I.E. AUST. R.P.E.Q. NO. 638)




8894-193 SANKEYS RD-FEDERAL               Page 4 of 13                        24/07/2023

Page 5

                                   SITE PLAN
                                                                           TEST LOCATIONS
                                                                        193 SANKEYS ROAD, FEDERAL
                                                                                                               NORTH
                             SANKEYS                  ROAD




                                                       ESS
                                                         ACC




                                                                      BH2
                                                                            P1

                                                                                      BH3

                                                                        BH1          P2
                                                                       Cut Bank


                                                                                            BH4
                                           NT
                                           ME
                                         SE
                                       EA
                                 S S
                              CE
                            AC




                                                        10
                                                           m
                                                                               193
                                                TP3



                                         TP2
                        0m




                                           240m2
                       24




                                         INDICATIVE
                                       DISPOSAL                      Heavily
                                                                     Treed
                                        AREA
                             TP1


                                                 Existing Gully
                                                Approximately 45m




8894-193 SANKEYS RD-FEDERAL                           Page 5 of 13                                24/07/2023

Page 6

Civil Quality Assurance T/A _ ABN 21 613397934

  

Civil Quality Assurance Pty Ltd

 

 

P.O. Box 1225, Nambour Qld 4560

For all Civil Testing

PH 0429 674334 Servicing South East Queensland

Project:__ 193 Sankeys Rd Requested By:__L.Robins
Federal Date Tested:__30-6-23

Client: _ Lachlan Robins Report No.:__A191

Drilling Method: Log of cutting Bore Hole No.:1

Depth Description Comment

Mm

00 Silty CLAY, medium to high plasticity, brown, some fine gravel/sand and some organics present,

moist, soft to firm (CI-CH)
300 SHALE STONE, fractured, light red/brown, quartz present, moist, weak
1500 Hole Terminated

Tests and sampling results relate only to the items tested or sampled. results applies to the sample received/( abnormalities may contribute to the report being

compromised) Reports shall not be reproduced except in full

6 Mill Lane Nambour
CQA Laboratory
ABN 21 61339 7934

Form R26 July 2021

8894-193 SANKEYS RD-FEDERAL

Approved Person:

Page 6 of 13

C. Templeton

Date: 10-7-23

24/07/2023

Page 7

Civil Quality Assurance T/A _ ABN 21 613397934

 

  

Civil Quality Assurance Pty Ltd
PH 0429 674334

Project:__193 Sankeys Rd
Federal
Client: __ Lachlan Robins

P.O. Box 1225, Nambour Qld 4560

For all Civil Testing
Servicing South East Queensland

Requested By:__L.Robins
Date Tested:__30-6-23
Report No.:__A191

Drilling Method: Hand Augured bore hole Bore Hole No.:2
Depth Description Comment
Mm

00 Silty CLAY, medium to high plasticity, brown, some fine gravel/sand and organics present,

300

500

moist, soft to firm (CI-CH)

SHALE STONE, fractured, light red/brown, quartz present, moist, weak

Hole Terminated in shale stone

‘Tests and sampling results relate only to the items tested or sampled. results applies to the sample received/( abnormalities may contribute to the report being
compromised) Reports shall not be reproduced except in full

6 Mill Lane Nambour

CQA Laboratory

ABN 21 61339 7934
Form R26 July 2021

8894-193 SANKEYS RD-FEDERAL

jes
Approved Person: ec of
C. Templeton

Date: 10-7-23

Page 7 of 13 24/07/2023

Page 8

Civil Quality Assurance T/A _ ABN 21 613397934 P.O. Box 1225, Nambour Qld 4560

  

 

 

 

Civil Quality Assurance Pty Ltd For all Civil Testing
PH 0429 674334 Servicing South East Queensland
Project:__193 Sankeys Rd Requested By:__L.Robins

Federal Date Tested:__30-6-23
Client: __ Lachlan Robins Report No.:__A191
Drilling Method: Hand Augured bore hole Bore Hole No.:3
Depth Description Comment
Mm
00 Silty CLAY, medium to high plasticity, brown, some fine gravel/sand and organics present,

moist, soft to firm (CI-CH)

400 SHALE STONE, fractured, light red/brown, quartz present, moist, weak
500 Hole Terminated in shale stone

Tests and sampling results relate only to the items tested or sampled. results applies to the sample received/( abnormalities may contribute to the report being

compromised) Reports shall not be reproduced except in full > FT
Approved Person: Gurl

6 Mill Lane Nambour C. Templeton

CQA Laboratory

ABN 21 61339 7934 Date: 10-7-23

Form R26 July 2021

8894-193 SANKEYS RD-FEDERAL Page 8 of 13 24/07/2023

Page 9

Civil Quality Assurance T/A ABN 21 613397934 P.O. Box 1225, Nambour Qld 4560

   

 

 

Civil Quality Assurance Pty Ltd

 

 

 

For all Civil Testing
PH 0429 674334 Servicing South East Queensland
Project:__193 Sankeys Rd Requested By:__L.Robins
Federal Date Tested:__30-6-23
Client: __Lachlan Robins Report No.:__A191
Drilling Method: Hand Augured bore hole Bore Hole No.:4
Depth Description Comment
Mm
00 Silty CLAY, medium to high plasticity, brown, some fine gravel/sand and organics present,
moist, soft to firm (CI-CH)
500 SHALE STONE, fractured, light red/brown, quartz present, moist, weak
600 Hole Terminated in shale stone

Tests and sampling results relate only to the items tested or sampled. results applies to the sample received/( abnormalities may contribute to the report being

compromised) Reports shall not be reproduced except in full
" me " ° . Approved Person: Ce Em
6 Mill Lane Nambour C. Templeton
CQA Laboratory
ABN 21 61339 7934 Date: 10-7-23
Form R26 July 2021

8894-193 SANKEYS RD-FEDERAL Page 9 of 13 24/07/2023

Page 10

ABN 21 613397934
Ph. 0429674334

Project:_193 Sankeys Rd

 

P.O. Box 1225, Nambour Qld 4560

For all Civil Testing
Servicing South East Queensland

TEST REPORT
Requested By:_L. Robins

 

 

 

Federal Date Tested: _30-6-23
Client: _Lachlan Robins Report No. A191
Field Test Procedure: AS/NZ 1547:2000
Sample method: Hand Auger Bore Hole
Hole Number: TP1 TP2 TP3
Radius of all holes(mm): 100 100 100
Depth of Holes(mm): 600 600 600
Impermeable Layer: n/a n/a n/a
Depth of water in Hole(mm): 250 250 250
Site Vegetation: Heavily treed with small shrubs
Soil Moisture: moist moist moist
What is the water table: n/a n/a n/a
Soil Classification see Bhl
Permeameter readings(mm/Hr): 25 25 aa

Permeameter Diameter: 150mm

6 Mill Lane Nambour

Form 4A September 2016

8894-193 SANKEYS RD-FEDERAL

Signatory: C. / —
C. Templeton &

Date: 10-7-23

Page 10 of 13 24/07/2023

Page 11

NORTH COAST GEOMECHANICAL CONSULTANTS
  CONSULTING ENGINEERS                                                                 1/36 Maud Street
 K.N. CROCKER, Dip. C.E. MIE.Aust                                     MAROOCHYDORE QLD 4558
               CPEng. No. 86019                                                     Phone 07 5443 2988
               RPEQ No. 638                                                           Fax 07 5443 5157
              LGEQ No. 544                                          Email: [email protected]

                                DESKTOP ANALYSIS
RESIDENCE AT 193 SANKEYS ROAD, FEDERAL
Lot. 6 RP216727
SOIL PERMEABILITY/SOIL CONDUCTIVITY TEST CALCULATION
AS/NZS 1547:2012
Q = RATE OF LOSS OF WATER FROM RESERVOIR (m³/min)
H = DEPTH OF WATER IN TEST HOLE (cm) r = RADIUS OF TEST HOLE (cm)
Ksat = SATURATED HYDRAULIC CONDUCTIVITY OF SOIL IN m/day
HYDRAULIC LOADING FOR 4-BEDROOM RESIDENCE.
     6    EQ. PERSONS         @          120     L/day/person =  720 L / Day
                                                                5040 L / Week
Based on AS1547, Table H1, On-Site Roof Water Supply
Ksat = 4.4Q[0.5 sinh-1(H/2r)-√{(r/H²)+0.25}+r/H]
                         2πH²
 TEST       FALL       Q               H                 R            Ksat       SOIL
                                                                                        STRUCTURE
 HOLE     (mm/5min) (cm³/min)        (cm)              (cm)          (m/day)   CATEGORY
    1        2.10       7.422         25                    5         0.062         5        Massive
    2        2.10       7.422         25                    5         0.062         5        Massive
    3        2.10       7.422         25                    5         0.062         5        Massive




SUMMARY OF PERCOLATION TEST HOLES
In Accordance with A.S.1547:2012 "On-Site Domestic Wastewater Management
                                                  IRRIGATION
                      PRIMARY SECONDARY SECONDARY
TEST RESULTS
                      TREATED  TREATED   TREATED
                                                     mm/day
 HOLE        Ksat.       DLR         DLR               DIR
   1         0.06        n.a.         5                 3
   2         0.06        n.a.         5                 3
   3         0.06        n.a.         5                 3

                                   Minimum
                                Area Required:                  240 metres2


DLR = DESIGN LOAD RATE FROM TABLE 5.2 AS1547:2012
in mm/day, based on SECONDARY TREATED EFFLUENT.
DIR = DESIGN IRRIGATION RATE FROM TABLE M1 AS1547:2012 in mm/day.
SECONDARY TREATED EFFLUENT ONLY PERMITTED.
TRENCH LENGTH = N/A
SOIL CAT. = SOIL CATEGORY DETERMINED FROM BORELOGS
(REFER TABLE 5.1 AS1547:2012)
N.R. = NOT RECOMMENDED


8894-193 SANKEYS RD-FEDERAL                 Page 11 of 13                                  24/07/2023

Page 12

                                                    240m2          Su
                                                                 Dive rface W
                                                                     rsio ate
                                                                         nM r
                                                                             oun
                                                                                 d




                              24m

                                                           10m


                                                    fall




8894-193 SANKEYS RD-FEDERAL         Page 12 of 13                                24/07/2023

Page 13

         SUITABLE PLANT SPECIES FOR OF LAND APPLICATION AREAS

             GENUS               SPECIES                 COMMON NAME

             Grasses
             Buffalo
             Kikuyu

             Ground Cover

             Acanthus            mollis
             Crinum              pedunculatum
             Hardenbergia
             Hibbertia           scandens
             Lonandra            longifolia
             Pennisetum          alopecuroides           Swamp Foxtail
             Ophiopogon
             Viola               hederacea               Native Violet

             Shrubs
             Baeckea             stenophylla             Weeping Baeckea
             Baeckea             vigata
             Banksia             robur                   Broad Leaved Banksia
             Callistemon         pachyphyllus            Wallum Bottlebrush
             Comesperma          defoliatum
             Leptospermum        juniperinum
             Leptospermum        laevigatum
             Leptospermum        liversidgei
             Leptospermum        semibaccatum
             Melastoma           affine                  Blue Tongue
             Pultenaea           paleacea

             THESE SPECIES ARE NOT SUITABLE WITHIN TEN METRES
             OF DISPOSAL AREA
             Banksia        integrifolia
             Callistemon    viminalis
             Callistemon    salignus
             Casuarina      cunninghamiana
             Casuarina      glauca             Swamp Sheoak
             Eucalyptus     intermedia         Red Bloodwood
             Eucalyptus     microcorys         Tallowood
             Eucalyptus     robusta            Swamp Mahogany
             Glochidion     ferdinandii        Cheese Tree
             Leptospermum   petersonii
             Lophostemon    suaveolens
             Melaleuca      armillaris
             Melaleuca      leucadendra
             Melaleuca      quinquenervia      Paperbarked Tea Tree



   To Flush Isn’t the End of the Line                                               2


8894-193 SANKEYS RD-FEDERAL              Page 13 of 13                          24/07/2023

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix D - On-site domestic wastewater evaluation report.pdf · 4.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.