PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION
Impact on Ecologically Important Areas
PO2 No acceptable outcome provided The existing vegetated condition surrounding the
Bushfire mitigation measures do not proposed building envelope is compliant with the
adversely impact on: requirements for the APZ as detailed in Section 5.2.1.
a) biodiversity values, connectivity and No vegetation clearing or other ecological impacts are
ecosystem functioning; and required to facilitate the bushfire mitigation measures
detailed in this report.
b) the long term physical integrity of
waterways, wetland and areas of native
vegetation.
Water Supply for Fire Fighting Purposes
PO3 AO3.1 Complies with AO3.1. The site is connected to a
Development provides an adequate Premises are connected to the reticulated water supply. reticulated water supply with a minimum flow and
water supply for firefighting purpose pressure of 10 litres a second at 200kPa at all times for
which is reliable, safely located and freely Editor's note—For reconfiguring a lot, water supply firefighting purposes.
accessible. needs to provide for a minimum flow and pressure of
10 litres a second at 200kPa at all times for firefighting
purposes.
OR
AO3.2
Where there is no available reticulated water supply,
the premises has:
a) an accessible dam, swimming pool or water tank
available for firefighting purposes with an onsite water
volume of not less than 5,000 litres; and
AUGUST 2026 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 26
380 MCKINNON DRIVE, COOROIBAH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D - Bushfire Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.