Council archive · source document
Appendix D - Bushfire Assessment · RAL26/0026
APPENDIX B – Flamesol Modelling
Calculated August 20, 2026, 10:00 am (MDc v.4.9)
SUB UNIT 1 - VHC 9.1
Minimum Distance Calculator - AS3959-2018 (Method 2)
Inputs Outputs
Fire Danger Index 48 Rate of spread 1.2 km/h
Vegetation
Forest Flame length 10.76 m
Classification
Understorey fuel
21 t/ha Flame angle 54 °, 64 °, 72 °, 77 °, 78 ° & 84 °
load
4.35 m, 4.83 m, 5.11 m, 5.24 m, 5.26 m & 5.35
Total fuel load 24.2 t/ha Elevation of receiver
m
Vegetation height n/a Fire intensity 15,124 kW/m
0.879, 0.864, 0.842, 0.8179999999999999,
Effective slope 0° Transmissivity
0.805 & 0.737
0.591, 0.4397, 0.2949, 0.2003, 0.1631 &
Site slope 0° Viewfactor
0.0445
Minimum distance to < 40
Flame width 100 m 9m
kW/m²
Minimum distance to < 29
Windspeed n/a 12.1 m
kW/m²
Minimum distance to < 19
Heat of combustion 18,600 kJ/kg 17.9 m
kW/m²
Minimum distance to < 12.5
Flame temperature 1,090 K 25.8 m
kW/m²
AUGUST 2026 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 34
380 MCKINNON DRIVE, COOROIBAH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.