Council archive · source document
Appendix D - Bushfire Assessment · RAL26/0026
Calculated August 20, 2026, 9:40 am (MDc v.4.9)
SUB UNIT 2 - VHC 22.1
Minimum Distance Calculator - AS3959-2018 (Method 2)
Inputs Outputs
Fire Danger Index 48 Rate of spread 1.34 km/h
Vegetation
Forest Flame length 12.16 m
Classification
Understorey fuel
23.4 t/ha Flame angle 53 °, 63 °, 71 °, 76 °, 78 ° & 83 °
load
4.85 m, 5.42 m, 5.75 m, 5.9 m, 5.95 m & 6.03
Total fuel load 28.4 t/ha Elevation of receiver
m
Vegetation height n/a Fire intensity 19,777 kW/m
0.877, 0.86, 0.836, 0.8110000000000001,
Effective slope 0° Transmissivity
0.798 & 0.733
0.5958, 0.442, 0.2971, 0.2018, 0.1643 &
Site slope 0° Viewfactor
0.0447
Minimum distance to < 40
Flame width 100 m 10.1 m
kW/m²
Minimum distance to < 29
Windspeed n/a 13.6 m
kW/m²
Minimum distance to < 19
Heat of combustion 18,600 kJ/kg 20.1 m
kW/m²
Minimum distance to < 12.5
Flame temperature 1,090 K 28.6 m
kW/m²
AUGUST 2026 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 35
380 MCKINNON DRIVE, COOROIBAH