                                      Calculated August 20, 2026, 9:45 am (MDc v.4.9)

                                                  SUB UNIT 3 - VHC 39.2

                                  Minimum Distance Calculator - AS3959-2018 (Method 2)

                   Inputs                                                     Outputs

 Fire Danger Index          48              Rate of spread                     0.35 km/h

 Vegetation
                            Woodland        Flame length                       3.26 m
 Classification

 Understorey fuel load      5 t/ha          Flame angle                        57 °, 68 °, 76 °, 82 °, 84 ° & 90 °

                                                                               1.22 m, 1.31 m, 1.28 m, 1.16 m, 1.06 m &
 Total fuel load            8 t/ha          Elevation of receiver
                                                                               0m

 Vegetation height          n/a             Fire intensity                     1,464 kW/m

 Effective slope            3°              Transmissivity                     0.896, 0.89, 0.882, 0.87, 0.862 & 0.792

                                                                               0.5686, 0.421, 0.2823, 0.1877, 0.1523 &
 Site slope                 3°              Viewfactor
                                                                               0.0413

                                            Minimum distance to < 40
 Flame width                100 m                                              2.8 m
                                            kW/m²

                                            Minimum distance to < 29
 Windspeed                  n/a                                                3.8 m
                                            kW/m²

                                            Minimum distance to < 19
 Heat of combustion         18,600 kJ/kg                                       5.6 m
                                            kW/m²

                                            Minimum distance to < 12.5
 Flame temperature          1,090 K                                            8.5 m
                                            kW/m²




AUGUST 2026                       BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN                                       Page: 36
                                          380 MCKINNON DRIVE, COOROIBAH

Used in these records

About this file

File size
4.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix D - Bushfire Assessment.pdf · 4.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.