The total width of any parapet wall does not exceed 50% of the
width of the front facade of a building.
Safety and amenity Table 6.3.2.3 Criteria for assessment (part)
Performance Outcomes Acceptable Outcomes
Safety and amenity
PO20 AO20.1
Development: Buildings and structures:
(a) provides a high level of residential amenity to users of the (a) are sited and orientated to minimise the likelihood of
subject site; and overlooking the private open space of adjacent residential
(b) does not unreasonably impact on the amenity enjoyed by uses;
users of adjoining or nearby premises, including privacy (b) avoid reduction of sunlight to at least 40% of the private
and access to sunlight. open space areas of any adjoining residences to less than
two hours between 9:00am and 3:00pm on any day of the
Editor's note—Provisions for sill height, glazing, screening and year;
window openings are to improve the residential amenity for (c) incorporate fencing, landscaping and screening to mitigate
occupants. Thermal performance requirements are contained in impacts on adjoining residential uses.
Queensland Development Code MP4.1 Sustainable Buildings.
Energy efficiency requirements are contained in the National Editor's note— refer to figure AP31A and figure AP32A
Construction Code.
AO20.2
Transparent doors and windows are designed and located so
they do not directly face transparent doors or windows or the
private open space areas of other dwellings within 10 metres;
AO20.3
Where windows, balconies, terraces, verandahs or decks
overlook or have the potential to overlook the private open space of
nearby properties or view into habitable room windows within 10
metres:
(a) windows have a sill height of not less than 1.7 metres
above finished floor level;
(b) windows and other openings are permanently screened to
a minimum height of 1.7 metres to avoid overlooking;
(c) windows and doors use translucent glazing to obscure
views; or
(d) windows or balconies are offset by 45 degrees or more.
Editor's note—refer to figure AP31A and figure AP31C
AO20.4
Planter boxes, screens, pergolas, landscaping and architectural
design of balconies are used to screen the ground floor private
open space of dwellings from separate upper level dwellings.
Editor's note—refer to figure AP31A
AO20.5
Permanently fixed external screening devices complement the
building's external materials and finishes and may incorporate
solid translucent screens, shutters, perforated panels or trellises
which have a maximum of 50% openings.
Editor's note—refer to figure AP31B
NOOSA PLAN 2020 Page 19 of 48
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.