Skip to the record
Accept no imitations.

Original source · versioned page text

Attachment 2 - Bushfire and Essential Managment Clearing

Attached to the e-mail Applicant Response to SARA Advice Notice - 132005.638.04.

of 3

Page text shows just the words. Original shows the document exactly as it was published.

            Essential
            management                                                                                                                               Necessary
            clearing set back                                                                                                                        clearing set back
            from proposed                                                                                                                            for radiant heat
            infrastructure - 1.5                                                                                                                     flux 29kW/m2 -
            times the tree ht -                                                                                                                      12.4m from
            24m                                                                                                                                      proposed
                                                                                                                                                     infrastructure




                                                                                                24m
                                                      12.4m
           New fence line




                                                                                                                                                     New fence line




                                                                                                                                                                                Attchment 2B
                                                                                                      USE FIGURED DIMENSIONS.    ISSUE AMMENDMENT   Title     Exempt and necessary clearing -
FLEXURE Pty Ltd                              CLIENT
                                                              NOOSA COUNCIL                           DO NOT SCALE FROM THE
                                                                                                      DRAWINGS. CONFIRM ALL
                                                                                                                                 date     details
                                                                                                                                                              proposed development
GRANT CALDER ARCHITECTURE AND URBAN DESIGN                                                                                                          Date
                                                                                                      DIMENSIONS ON SITE PRIOR                                   1 September 2025
                                                                                                      TO CONSTRUCTION OR
                                                                                                      FABRICATION. IT REMAINS                       Scale        1:500 @ A3
                                             PROJECT          RECYLE/TRANSFER STATION CENTRE          THE CONTRACTORS
21 Bursaria Street Peregian Beach                                                                     RESPONSIBILITY TO ENSURE                      Drawn        Grant Calder
                                                              SP298776 561 Noosa Eumundi Road         COMPLIANCE WITH ALL
ph: 0488 084 184
email - [email protected]                                  PLANNING APPLICATION                    RELEVANT CODES AND
                                                                                                      REGULATIONS IS                                Checked      Grant Calder
Registered Architect- BOAQ 3112                                                                       MAINTAINED AT ALL TIMES.
                                                                                                                                                    Drawing No   GC 147
                                                                                                                                                                    135 MPAC 2         Issue - 0
Log in to download the original file

Attachment 2 - Bushfire and Essential Managment Clearing.pdf · 955 KB (small file)