~,.., Carclno                                                                                               Noosa on Weyba
                                                                                          Water Supply and Sewerage Analysis




5.3            Noosa on Weyba Network

A network of trunk mains and smaller reticulations mains is required to maintain Unitywater’s DSS within the
Noosa on Weyba development. A hydraulic model was developed based on the results of the MWH report.
The network pressures identified in the MWH report have been adopted for the analysis of the Noosa on

Weyba development.
A primary connection to the existing 600mm diameter trunk main         along Eenie Creek Road via a 250 mm
diameter main along Walter Hay Drive is proposed. This main will provide the bulk of flow to the development
and is required to maintain non-residential fire flows (301/s)to the development.

A second 200       mm     diameter connection to the        existing   mains at Lake Entrance Boulevard should be
considered. This main would assist in the provision of flow to the western    properties within the Noosa on
Weyba development. It is not critical to maintain supply pressures as per the DSS to the proposed
development. However, the main would reduce dead ends in the proposed network. An internal 200 mm
diameter distribution main is proposed to convey flow to each precinct within the development. Some smaller
150 mm diameter mains will be required to maintain the fire flow DSS. The rest of the network would

comprise 100mm diameter mains as required to service properties.

Figure 1, illustrates the         NIDMA   network    and   the   proposed      mains to service the Noosa      on   Weyba
Development.




Northbrook Corporation Pty. LId                            Version 3                                      28 November 2012
5101-19                                             Commercial in Confidence                                        Page 12

Used in these records

About this file

File size
29.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 7 of 37 Appendix 5 - Water and Sewer Infrastructure Report MCU12_0208.pdf · 29.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.