is not supported given the buildings were compliant with the plot ratio requirements of the planning
scheme they were approved under, with a majority of the buildings established before 2008.
The predominant character of the area comprises smaller scale buildings which complies with all
applicable assessment benchmarks at the time of their application. A condition is included for plan
revisions and for the proposal to comply with the plot ratio requirements of the zone code.
Building Setbacks
Front Setback
Acceptable Outcome AO12.1 of the Medium Density Residential Zone Code requires buildings and
structures to be setback 6 metres (minimum) from frontages.
The development proposes retaining walls and stairs within the front setback and is non-compliant
with this control. The slope of the subject land makes it impossible to establish a basement without
retaining walls and the proposed terraced stairs with the alternative being significant cut at the
frontage to achieve the front setback requirements. The front setback variation is supported in this
instance as it is limited to the retaining wall structures and the terraced stairs.
Side (North)Setback
Acceptable Outcome AO12.1(b) requires building and structures to be setback 1.5 metres from the
side boundary up to 4.5 metres in height, 2 metres from the side boundary up to 7.5 metres in
height, and 2.5 metres where above 7.5 metres in height.
The application material indicates the proposal will have non-compliant side setbacks at the
northern boundary (Figure 25 below). The encroachment is limited to the privacy screen and
garden beds on the northern building wall, however, given the proposed building bulk and the
smaller scale nature of adjoining dwelling to the north, a condition will be included for plan
amendments to comply with the setback requirements.
Figure 25 – Proposed Section F
Basement Setback and Car Parking
Acceptable Outcome AO13 of Dual Occupancy and Multiple Dwelling Code requires car parking
to be provided in accordance with the Driveway and Parking Code.
Acceptable Outcome AO16 of the Medium Density Residential Zone Code requires basements to
not encroach into building setback areas. The proposed basement encroaches into the southern
setback and does not comply with this acceptable outcome. The performance outcome PO16
requires basements to be designed so that they are visually integrated with the building, do not
dominate the street and are screened through landscaping.
The application was referred to Councils Development Engineer and the following was noted:
Document Set ID: 22625793
Version: 14, Version Date: 03/04/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - MCU22 0139 CHANGED FROM COUNCIL REPORT [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.