               is not supported given the buildings were compliant with the plot ratio requirements of the planning
               scheme they were approved under, with a majority of the buildings established before 2008.
               The predominant character of the area comprises smaller scale buildings which complies with all
               applicable assessment benchmarks at the time of their application. A condition is included for plan
               revisions and for the proposal to comply with the plot ratio requirements of the zone code.


               Building Setbacks
               Front Setback
               Acceptable Outcome AO12.1 of the Medium Density Residential Zone Code requires buildings and
               structures to be setback 6 metres (minimum) from frontages.
               The development proposes retaining walls and stairs within the front setback and is non-compliant
               with this control. The slope of the subject land makes it impossible to establish a basement without
               retaining walls and the proposed terraced stairs with the alternative being significant cut at the
               frontage to achieve the front setback requirements. The front setback variation is supported in this
               instance as it is limited to the retaining wall structures and the terraced stairs.
               Side (North)Setback
               Acceptable Outcome AO12.1(b) requires building and structures to be setback 1.5 metres from the
               side boundary up to 4.5 metres in height, 2 metres from the side boundary up to 7.5 metres in
               height, and 2.5 metres where above 7.5 metres in height.
               The application material indicates the proposal will have non-compliant side setbacks at the
               northern boundary (Figure 25 below). The encroachment is limited to the privacy screen and
               garden beds on the northern building wall, however, given the proposed building bulk and the
               smaller scale nature of adjoining dwelling to the north, a condition will be included for plan
               amendments to comply with the setback requirements.




                                                    Figure 25 – Proposed Section F

               Basement Setback and Car Parking
               Acceptable Outcome AO13 of Dual Occupancy and Multiple Dwelling Code requires car parking
               to be provided in accordance with the Driveway and Parking Code.
               Acceptable Outcome AO16 of the Medium Density Residential Zone Code requires basements to
               not encroach into building setback areas. The proposed basement encroaches into the southern
               setback and does not comply with this acceptable outcome. The performance outcome PO16
               requires basements to be designed so that they are visually integrated with the building, do not
               dominate the street and are screened through landscaping.
               The application was referred to Councils Development Engineer and the following was noted:



Document Set ID: 22625793
Version: 14, Version Date: 03/04/2024

Used in these records

About this file

File size
12.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - MCU22 0139 CHANGED FROM COUNCIL REPORT [As Published].pdf · 12.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.