The development includes balcony areas to every room, at every level, and while the balcony areas
do not constitute gross floor area, they add significantly to the bulk of the building.
That proposed structures at the rooftop terraces including the lift and stairs exceeds the maximum
height requirements of the zone code and creates additional bulk to an already bulky building, the
proposed building bulk is likely to impact upon the visual amenity of adjoining and neighbouring
properties.
Roof Form (Rooftop Terrace)
Acceptable Outcome AO19.2 of the zone code also require developments to not include rooftop
terraces. The performance outcome PO19 requires roof forms to contribute positively to the local
skyline, complement the character of the locality and the topography of the site, and to not create
overlooking opportunities.
While the rooftop terraces have been designed with privacy screens to reduce impact from
overlooking to the north and south, the proposed rooftop terrace directly overlooks into the pool
and private open space areas of dwellings to the east. Specifically, the proposed roof terraces will
directly overlook bedrooms, private balconies, and courtyard areas of the dwellings at 33 Elanda
Street.
Figure 24 – Property to the east – opposite side of Elanda Street (33 Elanda Street, source Real Estate)
The party wall, lift shaft and stairs at the rooftop terrace level are non-compliant with the height
requirement, with these structures resulting in additional building bulk. The proposed rooftop
terrace will result in visual and overlooking impacts. The proposed structures at the rooftop level
are not supported, and a condition is included requiring plan amendments to delete the rooftop
terrace including the structures at the rooftop level and to comply with the plot ratio requirements
which will assist with reducing the bulk of the building.
Plot Ratio
Performance Outcome PO11 of the Medium Density Residential Zone Code requires the plot ratio
of development to not exceed 0.4:1. The development proposes a plot ratio of 0.44:1 and is non-
compliant with these performance outcomes. The proposed variation will result in substantial
conflict with the planning scheme, given the proposed building bulk and the number of variations
already sought for the development.
The applicant submits that the variation is marginal and the proposed plot ratio is similar to three
(3) of the sixteen (16) neighbouring buildings in the same zone as the subject site. This justification
Document Set ID: 22625793
Version: 14, Version Date: 03/04/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - MCU22 0139 CHANGED FROM COUNCIL REPORT [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.