Skip to the record
Accept no imitations.

Council archive · source document

SUPERSEDED Decision Notice - 010.2007.00001256.001 [As Published] · 132007.1256

of 14

Text shows just the words. Original shows the document exactly as it was published.

NOOSA COUNCIL IDAS Development Application Decision Notice                                                 4 of 14


11.    Security in the form of a cash bond or trading bank guarantee to the sum of $20,000 must be submitted,
       to secure performance of all conditions of this approval, prior to the issue of a Development Permit for
       operational works. The cash bond or trading bank guarantee will be returned on performance of the
       conditions of approval less any costs incurred by Council in respect of enforcing performance of this
       permit.

12.    The requirements of this development approval are to be effected, prior to the use of the premises.
       Council reserves the right to call upon the bond or guaranteed sum referred to in this approval to effect
       compliance with conditions.

13.    The Development Permit for a material change of use of premises lapses if the use has not happened by
       16 October 2011, unless an application to extend the currency is approved by Council.
Land Development

Vehicle Access
14.    A vehicular access driveway to serve the development shall be constructed from the Peregian Esplanade
       frontage of the site with a maximum width of 5.5m.

15.    The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
       vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
       without any step or level difference. Should any driveways be constructed to grades that do not comply
       with AS/NZS2890.1-2004, Council will require that the driveway be removed and reconstructed to levels
       that do comply.
       Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
       footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
16.    To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath, the
       driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
       line requirements as defined in AS2890.1, section 3.2.4. The applicant shall demonstrate compliance by
       illustrating these sight lines on the plans submitted for both Operational Works approval and Building
       Works approval.

17.    All vehicles shall enter and leave the site in a forward direction.
Car Parking
18.    A minimum of 4 covered carpark spaces shall be provided within the site as shown on drawing number
       “2007-01 SK-01” dated 13 June 2007 by Foster Designs except as modified herein.

19.    The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for user class A1
       with allowance for vehicles to enter and leave the site in a forward gear and with a minimum head
       clearance (headroom) at any point of 2.2m.

20.    All carparking shall be kept and maintained in a condition fit for use.
Frontage Works
21.    All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel, footpath
       paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications
       prior to commencement of the use permitted by this permit.

22.    All paths, driveways and parking areas shall be designed and constructed to ensure pedestrian safety
       using non-slip materials, to produce an evenly graded surface finish, and to be in accordance with the
       Disability Discrimination Act 1992 and Australian Standard 1428.1 Design for Access & Mobility.
Roof Water & Stormwater Drainage
23.    Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank minimum
       storage 3000 litres per unit that is installed to ensure water from the tank is used for external uses (such
       as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming pools, outdoor
       cleaning, etc) and for use in flushing of toilets internal to the dwelling. All rainwater tanks are to be
       designed and installed in accordance with the Queensland Development Code (QDC), Part 25 –
       Rainwater Tanks, and shall be part of the plumbing application in conjunction with the building approval.
       The location and capacity of the tanks shall be clearly shown on the plans submitted for Building Works /
       Operational Works approval and any overflow shall be directed to the road frontage located at Peregian
       Esplanade.




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@f00989a5\@[email protected]

Used in these records

About this file

File size
238 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED Decision Notice - 010.2007.00001256.001 [As Published].pdf · 238 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.