Council archive · source document
Response to Info Request -Attachment 7 - Bushfire Report MCU18-0015 & RAL18-0001 · MCU18/0015
Any reticulated or bottled gas shall be installed and maintained in accordance with AS1596 – 2002. Metal
piping is to be used. Any fixed LPG tanks shall be kept clear of flammable materials, and located on the non
hazard side of the building. Any gas cylinders which need to be kept close to a building shall have release valves
directed away from the building. Polymer sheathed flexible gas supply lines to gas meters adjacent to buildings
are not to be used.
7.5 Fire Fighting and Emergency Management Arrangements
The development is serviced by the proposed road and driveways for Emergency Services use. The
maintenance of a mown or slashed grass surface throughout the IPA provides safe defendable space around
key assets in the unlikely event of bush fire.
Obstructions to access to the rear of buildings should be avoided.
Residents and site operators shall be made aware of the existence of this Plan, and their need to comply with
the relevant provisions, in particular building construction, APZ maintenance, optimizing access around
buildings and emergency response preparations.
Residents shall decide on their Stay and Defend / or Go Early strategy before each fire season so as to ensure
this decision is not made too late, when smoke and emergency vehicles prevent an orderly evacuation. Staying
to defend or shelter is a viable and preferable option for the proposed development if the site is threatened by
smoke attack or worse.
Appendix 2 provides guidance for Residents’ Emergency Management Planning in relation to bushfire.
8.0 Assessment of proposal against The Noosa Plan (2017)
Division 9, Part 13.
Performance Criteria / Specific Outcome Probable / Acceptable Solutions
8.1 (O4) The proposed use does not The use is sited on land that is determined as medium hazard,
compromise the safety of people and however mitigation measures outlined in this BMP are
property from bushfire. applied, such that bushfire risk is reduced to an acceptable
level.
8.2 (O5) Community Uses and The proposed development does not involve Community
Infrastructure Uses, are able to function Uses or Infrastructure Uses.
effectively during and immediately after
bushfire events.
8.3 (O6) Public safety and the Solution 6.1 is applied in that hazardous materials are not
environment are not adversely affected manufactured or stored in bulk on the site.
by the detrimental impacts of bushfire on
hazardous materials manufactured or
stored in bulk.
8.4 (O7) Uses and works are sited, Solution S7.1 is applied in that uses and works, including
designed and constructed to – building works are sited on Lots > 2500m² :
a) minimise the number of people and iii) generally more than 10m from any retained vegetation
Report compiled by Bushfire Risk Reducers for Innovative Planning Solutions Page 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Info Request -Attachment 7 - Bushfire Report MCU18-0015 & RAL18-0001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.