Original source · versioned page text
20181085-ASC7 - Part 14 Assessement Criteria (Codes) (1)
Attached to the e-mail Operational Works Application OPW20/0114 - Email 2 of 4 - Civil Plans - Community Titles Scheme Statement - BUP - Part 14 Assessment Benchmarks - 4 Portside Crt, Noosaville.
Attached to the e-mail RE_ Proprietary Products & Compliance with SQUIDEP.eml, inside BP Noosaville - overview of proposed stormwater quality strategy related discussions.msg.
column 1 column 2
Including amendments to 8 June 2018
Specific Outcomes Acceptable solutions (if accepted
The Noosa Plan
development subject to requirements)
Probable solutions (if code assessment)
less.
14.97 Self-contained units - building works
O21 Building works do not result in an increase S21.1 A Detached House or Community
in the number of self-contained accommodation residence or dwelling unit contains no more
units or dwelling units on a property. than 1 kitchen and 1 laundry.
AND
O22 A Detached house accommodates 1 S22.1 Studios, pavilions or other habitable
household only. outbuildings have a maximum gross floor area
of 50m2;
AND
S22.2 No part of a Detached house or
Community residence containing habitable
rooms is more than 25m from another part of
the Detached house or Community
residence.
14.98 Protection of Extractive Resources
O23 Where located within proximity of S23.1 Where located within an extractive
protected extractive resources, building works resource area on Overlay Maps OM1.5—
for Residential Uses and Community Uses OM9.5, residential or community buildings—
incorporate design, orientation, and construction a) are located at least 200m from the
measures that mitigate the effects of noise, Extractive Resource/Processing Area; and
dust, ground vibration, or air blast overpressure b) achieve a minimum sound transmission
from the extractive industry. class rating of 30 for any windows or glass
doors on the wall closest to the Extractive
Resource/Processing Area.
Table 14-45 Removal buildings
14.99 Amenity
O24 The removal building does not have an S24.1 Any part of the removal building that is
adverse impact on the amenity of the premises affected by termite attack, borers, dry rot or
or surrounding premises. severe weathering is repaired or replaced using
new or sound second-hand materials;
Editor’s note: AND
Council’s Environmental Health Section has S24.2 Any part of the removal building that is
guidelines for the transportation and damaged as a consequence of relocation is
disposal of building materials containing repaired using new or sound second-hand
asbestos. Locally, asbestos can only be materials;
disposed of at Council’s landfill at Eumundi AND
Road Noosaville. S24.3 Where located in a town or village,
external surfaces of the removal building are
cleaned and painted.
Table 14-46 — Building works - Detached houses or Ancillary dwelling units - Rural or Rural
Settlement Zones
column 1 column 2
Specific Outcomes Acceptable solutions (if accepted
development subject to requirements)
Probable solutions (if code assessment)
14.100 Built form
Sloping sites & ridgelines
14-108
Building Works Code