Original source · versioned page text
20181085-ASC7 - Part 14 Assessement Criteria (Codes) (1)
Attached to the e-mail Operational Works Application OPW20/0114 - Email 2 of 4 - Civil Plans - Community Titles Scheme Statement - BUP - Part 14 Assessment Benchmarks - 4 Portside Crt, Noosaville.
Attached to the e-mail RE_ Proprietary Products & Compliance with SQUIDEP.eml, inside BP Noosaville - overview of proposed stormwater quality strategy related discussions.msg.
column 1 column 2
Including amendments to 8 June 2018
Specific Outcomes Acceptable solutions (if accepted
The Noosa Plan
development subject to requirements)
Probable solutions (if code assessment)
horizontal centres, with a maximum height of
0.75m, to avoid clumping and to retain
sightlines.
O6 Street trees and plantings in towns and S6.1 Street trees and trees in carparking areas
villages, carparks and other areas where achieve a maximum of 900mm clear trunk height
potential conflicts with vehicles and for a 2.0m high tree at planting and are able to
pedestrians are evident, are planted so as to attain a clear trunk height of 1900mm on maturity;
maximise vehicle and pedestrian safety. AND
S6.2 All scrub planting to be a maximum height of
700mm from the road pavement (not top of kerb).
Services and utilities
O7 All landscaping works maintain S7.1 Plant species used in landscaping adjacent
adequate safe distance from services and to substations, or adjacent to or on electricity
utilities including substations, overhead transmission line easements, are less than 4m
powerlines, power poles and transformers, high at maturity and do not encroach within 3m of
street lamps, stormwater catchment pits, and a substation boundary;
underground services and utilities. OR
S7.2 For trees higher than 4m, trees are planted
at a distance from any part of an electricity
Figure 14-17
transmission line at least equal to the expected
height of the tree at maturity (see Figure 14-17);
AND
S7.3 For power lines that connect to a premises,
the height of plant species at maturity provides for
a 2m clearance below the power line; (see Figure
14-18)
AND
S7.4 Trees and large scrubs are located a
minimum of—
a) 5m from electricity poles and pillars;
b) 4m from street lamps;
Figure 14-18 c) 2m from stormwater catchment pits; and
d) 2m from underground services and utilities;
AND
S7.5 Plants are located to enable tradespersons
to access, view and inspect service meters, such
as water and electricity meters;
AND
S7.6 Root barriers are installed around trees that
are located within 3m of any infrastructures or that
have potentially invasive roots.
14-136