                                                                      column 1                                           column 2
                 Including amendments 8 June 2018




                                                                  Specific Outcomes                       Probable solutions (if code assessment)
The Noosa Plan




                                                                                                       Figure 14-28–Noosa Heads Lions Park to
                                                    O3 Prescribed tidal works are not located on
                                                                                                       Weyba Bridge
                                                    the southern bank of the Noosa River and
                                                    tributaries between the Noosa Heads Lions
                                                    Park and Weyba Bridge (Refer Figure 14-28).

                                                    O4 Prescribed tidal work does not include
                                                    extensions of on-site recreational areas unless
                                                    there is a clear demonstrated public benefit and
                                                    public support.




                                                                                                                                                ENUE
                                                                                                                                          SIA AV
                                                                                                                         




                                                                                                                                      BANK
                                                                                                                                  E
                                                                                                                               RIV
                                                                                                                             AD
                                                                                                                           OS
                                                                                                                          NO

                                                    14.164 Character and Amenity
                                                    O5 Prescribed tidal works are designed and         S5.1 For lots with frontages greater than 15m or
                                                    sited to ensure—                                   greater in width, jetties and pontoons are setback
                                                    a) they are contained within the prolongation of   a minimum of 3m from the prolongation of the
                                                        boundaries of the lot;                         boundaries, except as allowed for in S5.2 and
                                                    b) that when a vessel is berthed it does not       S5.3; (Refer Figure 14-29);
                                                        encroach over the prolongation of
                                                        boundaries of the lot;                         Figure 14-29
                                                    c) a high level of visual amenity is maintained
                                                        when viewed from the watercourse and
                                                        adjoining lands;
                                                    d) they avoid conflicts with uses in the water
                                                        and on the foreshore and adjoining lands;
                                                    e) cluttering of watercourses is avoided;
                                                    f) excessive traffic volumes within foreshore
                                                        areas and adjoining lands are avoided;
                                                    g) materials blend with the natural surrounds;
                                                        and
                                                    h) they reflect the character and setting of the
                                                        immediate surrounds or the locality.
                                                                                                       OR
                                                                                                       S5.2 For lots less than 15m in width (including
                                                                                                       lots located in canal bends or on lots located in
                                                                                                       the head of the canal)—
                                                                                                       a) a joint application is made with the
                                                                                                             adjoining owner; or
                                                                                                       b) where a joint application is not possible,
                                                                                                             jetties and pontoons—
                                                                                                            i)     are setback a minimum of 1m from the
                                                                                                                   prolongation of the boundaries;
                                                                                                            ii) are not more than 1.2m in width; and
                                                                                                            iii) have no head and are located such
                                                                                                                   that when a vessel is berthed, it does


                                                                                                   14-164
                                                                                           Watercourses Works Code
Log in to download the original file

Part 14 Codes PIP to LGIP 8 June 2018.pdf · 3.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.