Specific Outcomes Probable solutions (if code assessment)
The Noosa Plan
O12 Uses are arranged within buildings and on
sites to enable external areas to be monitored. S12.1 Windows and main entrances are
positioned to allow for casual surveillance.
O13 Communal open space, including
congregation and seating areas, is located
S13.1 Communal open spaces, including
where it can be monitored;
congregation and seating areas, situated where
they are in the line of sight of windows, doors
and/or balconies of buildings, or can be seen
from a street or other public space.
O14 Buildings and structures are designed to S14.1 Where buildings or structures are
minimise opportunities for vandalism. constructed in view of a public street or
laneway—
a) the use of solid fences and blank walls
which attract graffiti is avoided. Where solid
blank surfaces are unavoidable,
landscaping, creepers, murals, vandal
resistant paint, etc are used;
b) toughened glass, security screens and
other measures (not including opaque
security shutters) are used in windows
which are provided at ground level, to deter
break and enters;
c) hardy vandal proof materials and anti-
graffiti paint are used in the construction of
buildings, where appropriate.
O15 Lighting of appropriate intensities is
S15.1 Lighting of appropriate intensities is
provided to maximise safety.
provided which satisfies the requirements of
Australian Standard AS1158: Public Lighting
Code, unless otherwise specified in this Code;
AND
S15.2 External lighting of a graduated intensity
is provided which starts at a lower level of
brightness at the perimeter of the site and rises
to a greater intensity at the entrance to
buildings, or at the centre of the site;
AND
S15.3 Lighting is directed onto the site and
away from neighbouring properties;
AND
S15.4 Vandal-resistant lighting is used in public
and publicly accessible areas.
O16 Public toilets are designed and S16.1 Features that may legitimise loitering,
constructed to: such as seating or public telephones are not
a) ensure the safety of all people using located in proximity to toilet entrances;
them; and AND
b) take advantage of informal surveillance S16.2 Public toilets are located in high traffic
from adjoining uses and activities, areas;
discouraging non-legitimate uses. AND
S16.3 Entrances to public toilets are visible from
the street, footpath and other activity areas on
the site or adjoining sites.