                                                                         column 1                                           column 2
                 Including amendments to 8 June 2018




                                                                     Specific Outcomes                       Probable solutions (if code assessment)
The Noosa Plan




                                                       O12 Uses are arranged within buildings and on
                                                       sites to enable external areas to be monitored.    S12.1 Windows and main entrances are
                                                                                                          positioned to allow for casual surveillance.
                                                       O13 Communal open space, including
                                                       congregation and seating areas, is located
                                                                                                          S13.1 Communal open spaces, including
                                                       where it can be monitored;
                                                                                                          congregation and seating areas, situated where
                                                                                                          they are in the line of sight of windows, doors
                                                                                                          and/or balconies of buildings, or can be seen
                                                                                                          from a street or other public space.

                                                       O14 Buildings and structures are designed to       S14.1 Where buildings or structures are
                                                       minimise opportunities for vandalism.              constructed in view of a public street or
                                                                                                          laneway—
                                                                                                          a) the use of solid fences and blank walls
                                                                                                              which attract graffiti is avoided. Where solid
                                                                                                              blank surfaces are unavoidable,
                                                                                                              landscaping, creepers, murals, vandal
                                                                                                              resistant paint, etc are used;
                                                                                                          b) toughened glass, security screens and
                                                                                                              other measures (not including opaque
                                                                                                              security shutters) are used in windows
                                                                                                              which are provided at ground level, to deter
                                                                                                              break and enters;
                                                                                                          c) hardy vandal proof materials and anti-
                                                                                                              graffiti paint are used in the construction of
                                                                                                              buildings, where appropriate.
                                                       O15 Lighting of appropriate intensities is
                                                                                                          S15.1 Lighting of appropriate intensities is
                                                       provided to maximise safety.
                                                                                                          provided which satisfies the requirements of
                                                                                                          Australian Standard AS1158: Public Lighting
                                                                                                          Code, unless otherwise specified in this Code;
                                                                                                          AND
                                                                                                          S15.2 External lighting of a graduated intensity
                                                                                                          is provided which starts at a lower level of
                                                                                                          brightness at the perimeter of the site and rises
                                                                                                          to a greater intensity at the entrance to
                                                                                                          buildings, or at the centre of the site;
                                                                                                          AND
                                                                                                          S15.3 Lighting is directed onto the site and
                                                                                                          away from neighbouring properties;
                                                                                                          AND
                                                                                                          S15.4 Vandal-resistant lighting is used in public
                                                                                                          and publicly accessible areas.

                                                       O16 Public toilets are designed and                S16.1 Features that may legitimise loitering,
                                                       constructed to:                                    such as seating or public telephones are not
                                                       a)    ensure the safety of all people using        located in proximity to toilet entrances;
                                                             them; and                                    AND
                                                       b)    take advantage of informal surveillance      S16.2 Public toilets are located in high traffic
                                                             from adjoining uses and activities,          areas;
                                                             discouraging non-legitimate uses.            AND
                                                                                                          S16.3 Entrances to public toilets are visible from
                                                                                                          the street, footpath and other activity areas on
                                                                                                          the site or adjoining sites.




                                                                                                      14-36
                                                                                                Community Uses Code
Log in to download the original file

20181085-ASC7 - Part 14 Assessement Criteria (Codes) (1).pdf · 3.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.