Table 14-2 Animal Husbandry




                                                                                                                                         Including amendments to 8 June 2018
                                                                                                                        The Noosa Plan
                        column 1                                                      column 2
                    Specific Outcomes                                     Acceptable solutions (if accepted
                                                                        development subject to requirements)
                                                                       Probable solutions (if code assessment)
14.7          Effects of use
Separation distances
O7 Sufficient separation distance and noise                         S7.1 For piggeries, the minimum separation
mitigation measures are provided between                            distance between use areas and sensitive
Animal husbandry uses and, existing                                 receptors is the greater of the following
infrastructure, ecologically important areas or                     distances—(other than land disposal areas such
sensitive receptors2 on other premises.                             as irrigated areas, on-site residential,
                                                                    administrative or staff facilities)
                                                                    a)     that identified in Table 6 in the DPI
                                                                           Separation Guidelines for Queensland
                                                                           Piggeries; or
                                                                    b)     that calculated using Section 2 of the DPI
                                                                           Separation Guidelines for Queensland
                                                                           Piggeries;
                                                                    OR
                                                                    S7.2 For piggeries the minimum separation
                                                                    distance between land disposal areas and
                                                                    sensitive receptors is not less than the
                                                                    distances shown in Table 7 of the National
                                                                    Environmental Guidelines for Piggeries 2nd
                                                                    edition;
                                                                    AND
                                                                    S7.3 For cattle feedlots—the minimum
                                                                    separation distance between use areas and
                                                                    sensitive receptors is not less than the distance
                                                                    calculated using Section 4 of the Reference
                                                                    Manual for Establishment and Operation of Beef
                                                                    Cattle Feedlots in Queensland;
                                                                    AND
                                                                    S7.4 For free to range poultry farms comprising
                                                                    of no more than 50 birds, the farm shed or
                                                                    housing structure is to be setback 40m from all
                                                                    property boundaries.
                                                                    S7.5 For other Animal husbandry uses, the
                                                                    minimum separation distances between use
                                                                    areas and boundaries of other premises and
                                                                    watercourses are not less than those identified
                                                                    in Table 14-4 below;


2
    “Sensitive receptors” is defined in the relevant Codes of Practice identified in Column 2.




                                                                14-5
                                                      Agricultural Uses Code
Log in to download the original file

20181085-ASC7 - Part 14 Assessement Criteria (Codes) (1).pdf · 3.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.