Including amendments to 8 June 2018
Specific Outcomes Probable solutions (if code assessment)
The Noosa Plan
Ancillary recreation uses
O5 Ancillary recreation uses, such as S5.1 If the use involves ancillary use of outdoor
outdoor tennis courts and half netball courts, courts including tennis courts, half courts and
do not have an adverse effect on the amenity netball courts—the use complies with the
enjoyed by users of adjacent or nearby requirements in Section 2 of PSP8 Tennis and
premises nor do they cause unreasonable Other Courts;
disturbance to local fauna through light AND
emissions, by ensuring that lighting devices
S5.2 A 3m wide landscaped buffer is provided
are limited to those designed and installed to:
between the tennis court and any boundary of the
a) minimise light spillage on neighbouring site;
premises;
AND
b) preserve an acceptable degree of lighting
S5.3 Any lit tennis court or sports court is located
amenity at the neighbouring premises;
at least 60m from the external wall of an existing
c) provide covers or shading around lights; or approved residential dwelling on an adjacent or
d) direct lights downwards; nearby lot (as measured from the centre line of
e) position lights away from possibly affected the court);
areas; and AND
f) enable brightness of lights to be adjusted S5.4 The vertical illumination resulting from
to low levels. direct, reflected or other incidental light emanating
from the site does not exceed 8 lux when
measured at any point 1.5m outside the boundary
AND and at any level from ground level upward;
AND
S5.5 Any flood lighting is restricted to the types
that give no upward component of light where
mounted horizontally (i.e. a full cut off luminare).
O6 Noise originating from the use of the
S6.1 The court is not used between the hours of
tennis court does not have a detrimental effect
10:00pm and 6:30am the following day.
on the amenity of the area or cause nuisance
to neighbouring residents.
Traffic and access
O7 Safe vehicular access is provided to and S7.1 Visitor Accommodation is directly accessible
from the site without adversely impacting on from a sealed road or a good standard gravelled
the safety of the road network; road;
AND
S7.2 Driveways do not exceed a gradient of 1 in
4 (25%);
AND
S7.3 Where the site gains access from part of the
Major Road Network, vehicle manoeuvring areas
are provided in accordance with Section 3 of AS
2890.1 Parking Facilities (Part 1: Off-street
Carparking) so vehicles enter and leave the site
in a forward gear.
Water supply and conservation
O8 An adequate, safe and reliable water
S8.1 & S9.1 Where outside a reticulated water
supply is available to the premises.
service area—
AND a) a rainwater tank of a minimum capacity of
4,000 litres is to be provided for each
O9 On-site water storage is designed and accommodation unit; and
operated to support the efficient use of water.
b) there is to be on the lot a dam, swimming
pool or water tank accessible for use by the