Appendix D - Letter and Concept Engineering Services Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn APPENDIX D
Letter and Concept Engineering Services Plan
Prepared by:
Contour Consulting Engineers Pty Ltd
www.bennettandbennett.com.au 210242_Town Planning Application.docx | August 2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 3 pages
Page 2
Our Reference: 2756-SW01
3 August 2021
Noosa Shire Council
PO Box 141
Tewantin QLD 4565
Attention: Development Services
Re: RECONFIGURATION OF LOT APPLICATION (1 INTO 2)
108 GOODWIN STREET, TEWANTIN
Dear Sir/Madam,
Contour Consulting Engineers (Contour) have been commissioned to prepare a concept civil
engineering plan in support of a Reconfiguration of Lot (RAL) application for a proposed 1 into 2
subdivision, at 108 Goodwin Street, Tewantin.
We understand that once the RAL approval has been issued that our Client will be lodging a separate
Operation Works (OPW) application for Council’s assessment.
Given there is no higher order approval in place prior to the completion of our Concept Civil design, we
have provided details of our proposed approach to the following key engineering matters:
• Driveways and Crossovers; and
• Stormwater Lawful Point of Discharge.
Engineering commentary on the above aspects of the civil design is provided below.
1 DRIVEWAYS AND CROSSOVERS
The existing driveway crossover will be retained to service proposed Lot 1.
A new crossover will be constructed to service proposed Lot 2. The location of the driveway will be
determined during detailed design. Street tree’s are to be retained along Goodwin Street, where
possible.
Refer Contour’s Concept design (2756-C01) for details regarding the location of the existing driveway,
attached within Appendix A.
CIV2756-SW01 – 108 Goodwin Street, Tewantin 1
MF/SC
Page 3
2 LAWFUL POINT OF DISCHARGE The subject site grades in a west to east direction towards Goodwin Street, with approximately 2.0m of fall across both allotments. We note that the existing dwelling will be demolished and minor earthworks will occur to accommodate two new flat building pads with minimal retaining walls. The site will continue to convey external flows as per pre-developed conditions. Roof water will be discharged via new kerb adapters to Goodwin Street, flowing to existing council stormwater infrastructure downstream within Goodwin Street. We consider the above provides a lawful point of discharge for the development and will enable non- worsening of peak discharges from the development to adjacent properties. Refer Contour’s Concept design (2756-C01) for concept earthworks, retaining wall locations and roofwater kerb adapters, attached within Appendix A. 3 SUMMARY Based on our investigative works, we consider that Council has no impediment to the approval of this development within the context of the driveway, crossover and/or stormwater. We therefore recommend that Council approves the application subject to reasonable, relevant, equitable and justifiable conditions. Yours Faithfully, Matt Folker – Civil Engineer For and on behalf of: CONTOUR CONSULTING ENGINEERS PTY LTD http://www.contource.com.au/ CIV2756-SW01 – 108 Goodwin Street, Tewantin 2 MF/SC
Page 4
W
W
PROPOSED RETAINING WALL Emt 'A'
(MAX WALL HT - 1.00m) SP298781 PROPOSED WATER METER
TO SERVICE LOT 1
EXISTING PROPERTY BOUNDARY
W
PROPOSED SEWER MAIN AND
CONNECTION TO LOT 1 LEGEND
9.20
0
E/OH
9.00
0
9. 0
8.8
8.6
8.4
9.2
T
0
0
0
EXISTING FEATURES
W
RL 9.20m OVERALL RP BOUNDARY
S S S
OVERHEAD ELECTRICAL
T
E/OH
W W W W T T TELSTRA
W
W W WATER RETICULATION
ROAD CENTRELINE
8.00
T
E/OH
ROAD KERB
W
8.20
S
PROPOSED BATTER LOT 1 PROPOSED ROOFWATER CONNECTION
CONCRETE DRIVEWAY
T
8.40
(MAX 1:3)
9.68
0 910m² (2 x KERB ADAPTERS)
W
TREE TO REMAIN
E/OH
8.60
APPROX. FFL 9.20m
8.80
9.00
9.20
9.40
9.60
9.80
LEGEND
T
PROPOSED FEATURES
W
S
RL 9.20m RL 9.20m
EXISTING DRIVEWAY CROSSOVER RP BOUNDARY
E/OH
TO BE RETAINED
1 RETAINING WALL
T
PROPOSED SEWER MAIN AND
RP128401 INDICATIVE BUILDING FOOTPRINT
W
RL 9.80m CONNECTION TO LOT 2
S EARTHWORKS CUT
RL 10.00m
E/OH
PROPERTY BOUNDARY
T
EARTHWORKS FILL
W
EARTHWORKS BATTERS
RL 9.50m S DN150 uPVC SN8 SEWER MAIN
T
E/OH
RL 9.50m
PROPOSED ROOFWATER CONNECTION SURFACE FLOW ARROWS
W
(2 x KERB ADAPTERS)
PROPOSED BATTER RL 9.20m INDICATIVE DESIGN SURFACE LEVELS
(MAX 1:3)
T
LOT 2
E/OH
W
910m²
GOODWIN STREET
EXISTING STRUCTURES:
APPROX. FFL 9.50m ALL EXISTING STRUCTURES TO BE DEMOLISHED AND REMOVED FROM SITE.
T
SUITABLE GEOTECHNICAL SUPERVISION REQUIRED WHEN FILLING
EXISTING SWIMMING POOL
W
E/OH
RL 9.50m
9.96.080
9.0
T
0 THE DESIGN IS CONCEPTUAL ONLY AND MAY CHAN
10.00
9.40
9.8
W
10.20
FOLLOWING THE PREPARATION OF DETAILED DESIG
9.8
0
9.2
0
IT IS ANTICIPATED THAT A DETAILED DESIGN WILL
E/OH
RL 9.50m 0
PREPARED, GENERALLY IN ACCORDANCE WITH THE
T
EXISTING WATER METER APPROVED CONCEPT DESIGN, AS PART OF A FUTUR
W
TO SERVICE LOT 2 APPLICATION FOR OPERATIONAL WORKS.
RL 10.00m
EXISTING PROPERTY BOUNDARY H
PROPOSED RETAINING WALL NOTE:
ALL TREES WITHIN WORKS FOOTPRINT TO BE
W
(MAX WALL HT - 1.00m) MH
EXISTING SEWER PROPERTY
CONNECTION TO BE DECOMMISSIONED EXISTING FOOTPATH TO BE ASSESSED ON SITE DURING CONSTRUCTION BY
RETAINED PROJECT ARBORIST
0 10 20 30 40 50m
SCALE 1:1000 A3
CONTOUR
SUNSHINE COAST OFFICE NORTH LAKES OFFICE
A.B.N. 62 117 061 659
PLAN DETAILS:
Designed:
Drawn:
Checked:
MF
MF
SC
PLAN AMENDMENTS:
Rev Date Comment Altered Checked PROPOSED SUBDIVISION CONCEPT ENGINEERING SERVICES P
AT 108 GOODWIN STREET, TEWANTIN
PLAN TITLE:
FOR STEPHAN VAN DER WALT
Building A, Level 1, Corporate Suite A, Bld 2 Datum: AHD
Date: 2/08/2021
6 Innovation Parkway, 2 - 4 Flinders Parade, FOR APPROVAL - NOT FOR CONSTRUCTIO
Birtinya 4575, Qld North Lakes 4509, Qld ISO 9001 UKAS
MANAGEMENT
...................... This plan is Copyright. Other than for the purposes of and subject to the conditions prescribed under the Copyright Act, no part of it may in any form or by
Ph. (07) 5493 9777
www.ContourCE.com.au
[email protected]
Trading name of SN Registrars (Holdings) Ltd
SYSTEMS
8327
Quality Assured International 3rd Party Accredited (FOR & ON BEHALF OF CONTOUR C/E PTY LTD)
any means be reproduced, stored in a retrieval system or transmitted without the prior written permission of Contour Consulting Engineers. The plan shall not
be used for construction without prior written approval.
PLAN No: 2756 - C01 REVISION: - SHEET: 1
FILE LOCATION: C:\12DS\DATA\CCE2K16DC01\02756 - 108 GOODWIN ST, TEWANTIN - LEGACY_117\DESIGN - CIVIL\AUTOCAD\WORKING\2756-C01(A).DWG
OF 1