2       LAWFUL POINT OF DISCHARGE
The subject site grades in a west to east direction towards Goodwin Street, with approximately 2.0m of
fall across both allotments.

We note that the existing dwelling will be demolished and minor earthworks will occur to accommodate
two new flat building pads with minimal retaining walls. The site will continue to convey external flows
as per pre-developed conditions.

Roof water will be discharged via new kerb adapters to Goodwin Street, flowing to existing council
stormwater infrastructure downstream within Goodwin Street.

We consider the above provides a lawful point of discharge for the development and will enable non-
worsening of peak discharges from the development to adjacent properties. Refer Contour’s Concept
design (2756-C01) for concept earthworks, retaining wall locations and roofwater kerb adapters,
attached within Appendix A.


3       SUMMARY
Based on our investigative works, we consider that Council has no impediment to the approval of this
development within the context of the driveway, crossover and/or stormwater. We therefore
recommend that Council approves the application subject to reasonable, relevant, equitable and
justifiable conditions.

Yours Faithfully,




Matt Folker – Civil Engineer
For and on behalf of:
CONTOUR CONSULTING ENGINEERS PTY LTD
http://www.contource.com.au/




CIV2756-SW01 – 108 Goodwin Street, Tewantin      2
MF/SC
Log in to download the original file

Appendix D - Letter and Concept Engineering Services Plan.pdf · 883 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.