FURTHER ADVICE - Attachment 1 - Minor Change Plans
Plans and drawings: the text below has words only, no drawings.
2800mm
New pergola, roof and gutter.
PERGOLA 2
rf2
f - 3deg
5 gu1 5
Existing box gutter to remain, inspect and
f
repair as necessary, refer hydraulic docs for
cut nom 15-20mm (5-10mm render, pc f works to outlets, sumps etc pc
10mm block - continuous reglet into
exiting block work/render. tuck
flashing and seal New parapet capping and flashing,
f pc replace all existing flashing associated with
pc f
rf3 new work, new outlets to box gutter, sumps
fall -
f - 3deg etc gu3
3deg
sh1 outlet to New roof and gutter, painted
200 f gu1 gutter below steel structure, Colorbond Delta pc
overlap to panel or equal. rf4
f rf1 f pc
f gu3
proposed
fallpergola
- 3deg gu3
proposed pergola
pc pc rf4 fall -
dp2 pc pc 3deg pc
dp gu2 dp
rf2 pc
dp1 - 100PVC pipe laid on roof f - 3deg
surface. paint. 316 SS brackets dp dp
ref hyd. eng doc gu1 PERGOLA 1
ROOF LANDSCAPED AREAS
non combustible separator at Total revised metal roof area - 1223m2 - reduction from 1251 - 28m2 - (-)2.2% current
wall shown red dashed - refer total landscaped area - site - 303m2
Pergola
to sheet 23 detail
Courtyard 1 existing planter 1 - 5m2 planting area
proposed pergola above new external entry stair shown grey - 53m2- sits below existing Existing planter 2 - 35m2 planting area
parapet. refer to elevation refer page TD 19 elevations Proposed
Courtyard 2 existing planter 1 - 5m2 planting area
proposed roofed pergola - ground level - 40m2 Existing planter 2 - 34m2 planting area
additional pergola is 93m2 new planter 1 - 9m2 planting area
net increase of external shaded and rain protected areas - 65m2 new planter 2 - 5.2m2 planting area
revised total landscaped area - 27ym2
all new work is below the current building parapet - refer elevation net reduction in planting area is 26m2 - 8.5%
DESIGN INTENT OF PROPOSED WORKS: provide improved visitor and staff amenity to external areas - upgrade existing non compliant and stair and access
in courtyard 1. Remove defective and unsightly roof in level 1 courtyard 1 and balcony. Remove defective planter boxes in courtyard 1, and 2 replace with
upgraded planter boxes. Reduce areas of metal roof and increase batten and shaded poly carbonate pergola structures to courtyards 1 and 2. Provide shaded
seating areas in both courtyards. Provide improved visitor access to courtyards 1 and 2.
0 2000mm 5000mm 10000mm
FLEXURE Pty Ltd USE FIGURED DIMENSIONS. ISSUE AMMENDMENT Title
CLIENT
THE BODY CORPORATE OF NOOSA CENTRAL DO NOT SCALE FROM THE date details
PLAN ROOF NEW
DRAWINGS. CONFIRM ALL Date 03 April 2025
GRANT CALDER ARCHITECTURE AND URBAN DESIGN DIMENSIONS ON SITE PRIOR
TO CONSTRUCTION OR
FABRICATION. IT REMAINS Scale
PROJECT NOOSA CENTRAL STAGE 2, 6 Bottlebrush Avenue Noosa Junction - THE CONTRACTORS
RESPONSIBILITY TO ENSURE Drawn Grant Calder
21 Bursaria Street Peregian Beach
ph: 0488 084 184 ALTERATIONS AND IMPROVEMENTS - TENDER SET COMPLIANCE WITH ALL
RELEVANT CODES AND
email - [email protected] REGULATIONS IS Checked Grant Calder
Registered Architect- BOAQ 3112 MAINTAINED AT ALL TIMES.
Drawing No GC 138 TD 16 Issue - 0