FOR INFORMATION ONLY
EXISTING COLUMNS
CENTRE LINE OF
EXISTING COLUMNS
EXISTING COLUMNS
CENTRE LINE OF
CENTRE LINE OF
ALLOWANCE TO BE MADE FOR ANY
ADDITIONAL SUPPORT @ WINDOW HEAD
EXISTING PERIMETER BEAM EXISTING PERIMETER BEAM
& ROOF STRUCTURE
CUSTOM COLORBOND FLASHING NEW CUSTOM FOLDED COLORBOND
HEAD FLASHING
PACKER & SEALANT BEAD &
BACKING ROD PACKER, SEALANT BEAD & BACKING ROD
10 FLASHING
FLASHING 10
NEW ALUMINIUM DOORS SUB HEAD PROFILE/
MOISTURE RESISTANT PLY SUBSTRATE ON DEFLECTION HEAD
SUB HEAD PROFILE/ INSTALLED TO MANUFACTURES
BATTENS BUILT TO FALLS
DEFLECTION HEAD NEW ALUMINIUM BIFOLD SPECIFICATIONS
WINDOWS INSTALLED TO
LINE OF EXISTING POST BEYOND
MANUFACTURES SPECIFICATIONS
APPLIED WATERPROOF MEMBRANE TO LINE OF EXISTING POST BEYOND EXISTING DOWNPIPES TO
ENTIRE ROOF CARRY UP AND OVER REMAIN, PROTECT & MAKE
WINDOW SILL GOOD ANY DAMAGE UPON
COMPLETION
CUSTOM FOLDED COLORBOND FLASHING
MOISTURE RESISTANT PLY LINED HOB
WITH COLORBOND FLASHING TO MATCH
WINDOW FRAMES
FLASHING DRIP EDGE
& HIDDEN FIXING
EXISTING STRUCTURE
10 10
CEMINTEL BARESTONE CLADDING FIXED ON BATTENS IN
SEALANT BEAD ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND
DETAILS
ROOF FRAMING TO SUIT 10
10
INSULATION TO MEET BCA REQUIREMENTS
PACKER & SEALANT BEAD &
BACKING ROD
FLASHING
FALL
SEALANT BEAD
RP89
Raven Technical Data Sheet
Weather - Energy Sweep Seal
for Aluminium hollow channel door suites
9.4 mm
A rigid & flexible copolymer, Weather
and Energy Seal. 9.5 mm
Raven RP89 suits leading proprietary
brand, hollow channel aluminium door 43.0 mm
suites. Seal Material
Concealed in the bottom of A black rigid & grey flexible UV stabi-
Alluminium butt hinged doors or lised copolymer.
the bottom and head of pivot doors,
RP89’s unique design accommodates Durability
factory and retrofit applications. Seal tested to 500,000 operating cy-
When used in conjunction with a cles without failure.
EXISTING DOUBLE BRICK WALL
Raven threshold plate an excellent
weather and energy seal is achieved. Used in Conjunction with Raven
threshold plates and perimeter seals.
Location
40-45mm hollow channel aluminium
commercial doors. Suits Butt hinged
and pivot hinged systems. Sliding
doors (user determined) Note: Seal to
coordinate with other door hardware
430
(user determined).
Min/Max gap
6mm - 9mm to threshold plate or
raised sill. Note: threshold plate
recommended for RP89 sweep seal
to clear floor surface.
BRICKWORK TO MATCH EXISTING
Fixing method
Snap fit includes two end support
lugs with self drill screws. (supplied)
TO MATCH EXISTING ADJACENT
RAVEN
*RP116 Threshold Plate Shown *RP115 Threshold Plate Shown
For contact information visit - Australia & Oceania: www.raven.com.au - Europe: www.ravenseals.com - Asia: www.ravenseals.co.cn
Raven door seals are guaranteed for 2 years against defects in materials and workmanship, provided seals are fitted in accordance with manufacturer’s specifications.
Defective goods will be replaced. However, NO claim for work done thereon or damage incurred will be allowed. All technical data and recommendations, although based
upon our research and believed to be reliable, are given in good faith but without warranty. It is understood that users will independently determine the suitability of products
shown herein for their purposes and as such Raven Products Pty Ltd accepts no liability. Due to progressive development Raven Products reserve the right to modify speci-
fications and descriptions without prior notice. The tradename Raven and its registered trademarks remain the property of Raven Products Pty Ltd, Australia. Product num-
bers, drawings and technical details are copyright. Reproduction is by written permission only and must accompany the Raven brand and copyright acknowledgement.
FALL FALL
880
450
EXISTING CONCRETE SEAT POURED CONCRETE INFILL
INSTALL NEW RAVEN RP116
ACCESSIBLE THROSHOLD PLATE
& RP89 ENERGY SWEEP SEAL
FFL FFL FFL OF EXISTING CRAZY PAVE FLOOR
FINISH
480 350 480
D2 DETAIL
DETAIL SCALE 1:10
D3 DETAIL 3 PERSPECTIVE VIEW PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
DETAIL SCALE 1:10 DETAIL SCALE 1:10
notes : issue amendment log by date issue amendment log by date project: north
01 PRELIMINARY, PRELIMINARY BA ISSUE TJP 09-06-21
date: APR 2021
1 The designs, drawings and specification are 02 PRELMINARY BA ISSUE TJP 15-07-21 PARKRIDGE FACILITIES BUILDING
copyright and always remain the property of UPGRADES drawn:
Blackburne Jackson Design Pty Ltd.
A R C H IT E C T UR E | L A ND S C A P E | INT E R IO R | P R O J E C T M A N A G E M E N T checked:
2 Before commencing construction: client:
- Verify all dimensions and levels.
- Verify location and levels of all services on site. ALTUM CONSTRUCTIONS scale: 1:10, 1:5
- Verify that floor levels and finished levels will 37 Aerodrome Rd Maroochydore Qld title:
enable connection to services. P.O. Box 154 Cotton Tree Qld 4558 phone 07 5443 3200 project/drawing no. sheet: A1
email [email protected] fax 07 5443 4030 FACILITIES BUILDING ADDITIONS -
3 Do not scale this drawing.
When in doubt refer to Architects. DETAILS 5737_A07-01_02
5737-22-PARKRIDGE FACILITIES UPGRADES.pln printed: Friday, 16 July 2021 11:30 am
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Facilities Building Minor Change to Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 32.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.