EXISTING BRICK SILL & SEAT BELOW
EXISTING BRICK SILL & SEAT BELOW
BIFOLDING WINDOW SUITE INSTALLED TO
BIFOLDING WINDOW SUITE INSTALLED TO
MANUFACTURERS SPECIFICATIONS & DETAILS
MANUFACTURERS SPECIFICATIONS & DETAILS
EXISTING STUD FRAMED WALL WITH
EXISTING STEEL CHS COLUMN WEATHERBOARD TYPE CLADDING CUT BACK
CLADDING FLASH & SEAL AS REQUIRED TO
ACHIEVE WATER TIGHT CONNECTION
150 STEEL STUD FRAME
C.
COLORBOND FLASHING COLORBOND FLASHING COLORBOND FLASHING
E T
S
K ER
LOC
E L
ARC
P COLORBOND FLASHING
H OW
O S
D T
ATE
PD
COLORBOND FLASHING COLORBOND FLASHING
CEMINTEL EXTERNAL BARESTONE
E U
OB
CLADDING
T T
YE
VAPOUR BARRIER / SARKING
COLORBOND CLADDING BASE FLASHING COLORBOND FLASHING
AROUND FULL PERIMETER
CEMINTEL EXTERNAL BARESTONE
CLADDING
DOUBLE DOOR & SIDE LIGHT SUITE
INSTALLED TO MANUFACTURERS
SPECIFICATIONS & DETAILS
COLORBOND CLADDING BASE FLASHING
AROUND FULL PERIMETER
D7 INFILL WALL DETAIL D10 INFILL WALL DETAIL
PLAN DETAIL SCALE 1:5 PLAN DETAIL SCALE 1:5
FOR INFORMATION ONLY
EXISTING COLUMNS
CENTRE LINE OF
EXISTING WALL & FINISHES
TO REMAIN WHERE POSSIBLE EXISTING STRUCTURE &
PROTECT & MAKE GOOD ANY FINISHES TO REMAIN,
DAMAGE UPON COMPLETION PROTECT AS NECCASSARY &
REPAIR ANY DAMAGE
CEMINTEL EXTERNAL BARESTONE
CLADDING
STUD FRAME & BULK INSULATION
TO MEET SECTION J REQUIREMENTS
CUT IN NEW LINTEL AS REQUIRED
VAPOUR BARRIER / SARKING HEAD FLASHING
DPC
COLORBOND FLASHING
NEW TILES TO MATCH
EXISTING OVER VILLABOARD
SUBSTRATE
FLASHING
EXISTING BRICK WALL
X
BOXED COLORBOND CABLE & CONDUIT DUCT
REBATE BIFOLD BOTTOM PACKER, SEALANT
GUIDE INTO BENCHTOP BEAD & BACKING ROD
SUB HEAD PROFILE/
FRAME DOWN AS REQUIRED TO
DEFLECTION HEAD
SUIT DEPTH OF A/C CASSETTE
BENCHTOP / SERVERY
STONE TO MATCH EXISTING
NEW ALUMINIUM AWNING
WINDOWS INSTALLED TO
MANUFACTURES SPECIFICATIONS
TYPICAL INFILL WALL BASE FLASHING DETAIL
DETAIL SCALE 1:5
MAKE ALLOWANCE FOR SUITABLE
SUPPORT BRACKETS TO CARRY
BENCHTOP & ADDITIONAL LOAD
SUBSILL PROFILE BY WINDOW
MANUFACTURER
NEW WEATHERBOARD
CLADDING TO MATCH PACKER, SEALANT BEAD & BACKING ROD
EXISTING
NOTE:
NEW TILES TO MATCH MAKE ALLOWANCE FOR AUTO
EXISTING OVER VILLABOARD OPENING MECHANISM ADJUST
1200
SUBSTRATE
DETAIL AS REQUIRED TO SUIT
NEW STUD FRAME WALL & BULK
INSULATION TO MEET SECTION J
REQUIREMENTS EXISTING STRUCTURE &
FINISHES TO REMAIN,
PROTECT AS NECCASSARY
VAPOUR BARRIER / SARKING & REPAIR ANY DAMAGE
NEW COVED VINYL FLOOR FINISH
D5 PIZZA / DRY BAR D6 HIGH LEVEL GLAZING
DETAIL SCALE 1:10 DETAIL SCALE 1:10 PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
notes : issue amendment log by date issue amendment log by date project: north
01 PRELIMINARY, PRELIMINARY BA ISSUE TJP 09-06-21
date: APR 2021
1 The designs, drawings and specification are PRELIMINARY ISSUE, TIMBER BENCH NOW
PARKRIDGE FACILITIES BUILDING
copyright and always remain the property of 02 STONE, A/C CASSETTE ALLOWED FOR ABOVE
HIGH WINDOWS
TJP 24-06-21 UPGRADES drawn: TJP
Blackburne Jackson Design Pty Ltd.
03 PRELMINARY BA ISSUE TJP 15-07-21
A R C H IT E C T UR E | L A ND S C A P E | INT E R IO R | P R O J E C T M A N A G E M E N T checked: NK
2 Before commencing construction: client:
- Verify all dimensions and levels.
- Verify location and levels of all services on site. ALTUM CONSTRUCTIONS scale: 1:10, 1:5
- Verify that floor levels and finished levels will 37 Aerodrome Rd Maroochydore Qld title:
enable connection to services. P.O. Box 154 Cotton Tree Qld 4558 phone 07 5443 3200 project/drawing no. sheet: A1
email [email protected] fax 07 5443 4030 FACILITIES BUILDING ADDITIONS -
3 Do not scale this drawing.
When in doubt refer to Architects. DETAILS 5737_A07-02_03
5737-22-PARKRIDGE FACILITIES UPGRADES.pln printed: Friday, 16 July 2021 11:31 am
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Facilities Building Minor Change to Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 32.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.