Skip to the record
The gold standard in government transparency.

Original source · versioned page text

210723 23 - 2 Pandorea Court, Noosaville Town Planning Report

of 35

Page text shows just the words. Original shows the document exactly as it was published.

                                                   Any shipping containers, railway         No shipping containers or railway
                                                   carriages or similar are placed          carriages are proposed.
                                                   behind a dwelling house and not
                                                   visible from the street.
 PO13                                              AO13.1                                   AO13.1-AO13.5 Not Applicable
 Garages and carports are                          No more than three garage doors,         No garages are proposed.
 designed and sited to visually                    having a combined total width not
 integrate with the dwelling and                   exceeding 7.2 metres present to
 avoid dominating the street by:                   the street front.
                                                   AO13.2
       (a) minimising the width of                 Double width garages do not occur
           the garaging structure;                 on any lot less than 10 metres
       (b) minimising projection of                wide.
           the structure forward of                AO13.3
           the main face of                        On a lot less than 12.5 metres wide
           the dwelling; and                       double garages are permitted only
       (c) ensuring the pedestrian                 where:
           entrance / front door is
           visible from the front                       (a) the lot is at least 10 metres
           property boundary.                               wide;
                                                        (b) the building is more than
                                                            one storey in height; and
                                                        (c) the total width of the
                                                            garage does not exceed
                                                            60% of the width of the lot.
                                                   AO13.4
                                                   On lots with a width of at least 12.5
                                                   metres but not exceeding 14
                                                   metres the total width of the garage
                                                   does not exceed 50% of the width
                                                   of the lot and garage doors do not
                                                   exceed a total width of 6 metres.
                                                   AO13.5
                                                   On lots with a width of more than
                                                   14.0 metres, garage doors within
                                                   10 metres of the front boundary do
                                                   not present a combined width of
                                                   more than 6.7 metres or 40% of the
                                                   lot width whichever is the lesser.

                                                   Editor’s Note— The lot width
                                                   would be measured at
                                                   the frontage unless the lot was
                                                   irregular in shape being for
                                                   example on a bend or at the head
                                                   of a cul-de-sac, in which case it
                                                   would be the width of the lot in line
                                                   with the front of the garage.
 PO14                                              AO14                                     AO14 Not Applicable
 Basements (including the entry                    Basements:                               The proposal at hand does not
 points to them):                                       (a) are limited to one access a     involve a basement.
                                                            maximum of 6 metres wide;
       (a) do not dominate the                              and
           street or building design;                   (b) do not encroach into
       (b) visually integrates with                         boundary setback areas.
           the residential building;




18

Building Work (Development Permit)
Extensions to a Dwelling House – 23/2 Pandorea Court, Noosaville
Log in to download the original file

210723 23 - 2 Pandorea Court, Noosaville Town Planning Report.pdf · 1.1 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.