Original source · versioned page text
220902 AGLA Essence David Low Way (215), Peregian Beach issue G
Very large file (34.2 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
PROPOSED ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
QLD 4122
Landscape Design Development Package
T 07 3420 0006
M 0405 389 243
E [email protected]
Prepared GENERAL NOTES:
1. Read all landscape drawings and specifications and clarify
any discrepancies with the Project Manager prior to
undertaking works.
By For 2. All work practices shall comply with the Occupational
Health and Safety Act 2004 and all relevant regulations and
codes of practice.
3. The location of the site compound and area for stockpiling
of materials is to be agreed on site and authorized by the
Project Manager prior to the commencement of works.
4. The site is to be secured for the full duration of works at the
Contractor’s expense.
5. The Contractors must check all dimensions and levels on
site. The proposed works must match into existing site
levels where they interface with existing conditions.
6. The Contractor is to locate and confirm all existing services
and service covers, whether shown on the drawing or not,
prior to the commencement of works. The Contractor shall
contact Dial Before You Dig to obtain any relevant service
information prior to the commencement of works.
7. The Contractor is responsible for retaining, protecting and
repairing any damage to all existing services, service
covers etc. The Contractor shall advise the Project
Manager of any required alternations.
8. Confirm all pit levels and resolve any discrepancies with the
Project Manager prior to undertaking the works.
9. All levels are to be approved on site by the Project Manager
at setout prior to undertaking the works.
10. All surface levels nominated on the plans are finished
surface levels. The Contractor must include excavation,
trimming and grading to appropriate sub-grade levels to
SITE LOCATION PLAN SCHEDULES achieve specified depth and adequate drainage of softfall
mulch.
DRAWING SCHEDULE 11. Sub-grade in softfall mulch zones to have minimum of 1:50
fall towards agricultural drains. Typically provide falls
DWG NO DRAWING TITLE ISSUE across hard surfaces towards gardens beds.
Minimum fall in direction of travel – 1:90
David Low Way
0 COVER SHEET G
Maximum fall in direction of travel – 1:20
1 LANDSCAPE WORKS NOTES G Maximum crossfall – 1:40
2a PLANTING SCHEDULE G
2b PLANTING IMAGES G
3 OVERALL LANDSCAPE PLAN G
4 PROPOSED FENCES PLAN G
5 EXISTING TREES PLAN G
6 SURFACE FINISHES PLAN 1 G
7 SURFACE FINISHES PLAN 2 G
8 SURFACE FINISHES PLAN 3 G
9 SURFACE FINISHES PLAN 4 G
10 SURFACE FINISHES PLAN 5 G
11 PLANTING PLAN 1 G
12 PLANTING PLAN 2 G
13 PLANTING PLAN 3 G
14 PLANTING PLAN 4 G
15 PLANTING PLAN 5 G G 02/09/22 UPDATED ARCHITECTURAL DWGS
16 PLANTING PLAN 5 G F 18/02/20 IN RESPONSE TO NC IR
17 DETAILS G E 12/07/19 UPDATED ISSUE FOR TENDER
D 10/07/19 COORDINATION ISSUE
18 DETAILS G C 28/06/19 FOR TENDER
B 28/06/19 FOR REVIEW
A 26/06/19 FOR REVIEW AND COORDINATION
ISSUE DATE REASON
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
DRAWING REFERENCE SCHEDULE AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
CONSULTANT TYPE DRAWING FILE NAME DATE RECEIVED RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
MORGAN CONSULTING ENGINEERS CIVIL DRAWING 19-06-25 - 18164 - MCE CIVIL BASE.DWG 25/06/19
RED DOOR ARCHITECTURE ARCHITECTURAL DRAWING WD-A-100-SITE-PLAN---GROUND-FLOOR-DETAIL-REV.15 25/08/22
180082-WD-B-100-5 - GROUND FLOOR PLAN.DWG 11/07/19
180082-WD-C-100-1 - FLOOR PLANS (KAMALA).DWG 03/06/19
180082-WD-D-100-1 - FLOOR PLANS (LILY).DWG
N 180082-WD-E-100-1 - FLOOR PLANS (MARRAM).DWG
180082-WD-F-100-1 - FLOOR PLANS (SALTBUSH 1).DWG
180082-WD-G-100-1 - FLOOR PLANS (SALTBUSH 2).DWG ESSENCE OF PEREGIAN BEACH
180082-WD-H-100-1 - FLOOR PLANS (WALLUM).DWG
215 DAVID LOW WAY, PEREGIAN BEACH
COVER SHEET
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 0 G AL/CP AG/NC
NOT FOR CONSTRUCTION
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.
Full text of sections 2 to 6 (of 22)
Section 2
GENERAL NOTES LIGHT BOLLARDS
SUPPLIER: Centenary Landscape Supplies Ph (07) 3373 4999 or equal approved.
A. ARCHITECTURAL WORKS INFORMATION GENERALLY: Bollard lights to be installed under the electrical contract. If they are installed prior to landscape
Refer to Architect's drawings for all information contained within these documents related to and nominated as INORGANIC MULCHING - AS INDICATED works, ensure they are protected and maintained during works or rectified with like for like if damaged during
Architectural Works. This includes all hardscape items such as paving, outdoor structures / shelters, walls and works.
fencing. Architectural Works information contained within these documents are indicative only and not for GENERALLY: Install inorganic mulch to a minimum of 75mm entirely over planting areas as indicated on the
construction or certification purposes. drawings. Weed mat to be installed in all areas of inorganic mulch. Refer engineer’s drawings for specification and locations as required.
B. CIVIL WORKS INFORMATION MATERIAL: Inorganic mulch to be Tenterfield Pearl 20-40mm subject to sample. FENCING ANDREW GOLD LANDSCAPE ARCHITECTURE
Refer to Civil Engineer's drawings for all information contained within these documents related to and
SUPPLIER: Centenary Landscape Supplies Ph (07) 3373 4999 or equal approved. GENERALLY: Install fencing, screens, gates and associated locks and fixings in the locations as shown on the PO BOX 5220
nominated as Civil Works. Civil Works information contained within these documents are indicative only and not MT GRAVATT EAST
for construction or certification purposes. drawings. The construction, finishing, fixings, wind loading, footings and final design will be undertaken by an QLD 4122
PODIUM PLANTERS engineer/ builder. The images and landscape drawings show the extent and design intent and the final finish
C. STRUCTURAL WORKS INFORMATION should be coherent with similar elements on site or as discussed with the landscape architect. T 07 3420 0006
M 0405 389 243
Refer to Structural Engineer's drawings for all information contained within these documents related to and TOPSOIL: E [email protected]
nominated as Structural Works. This includes retaining walls. Structural Works information contained within Supply and install imported topsoil suitable for podium planters (UltraGrow Platinum Podium and Container FENCE TYPE A1: 1500mm or 1800mm high fence (in outdoor shower locations) with 50 x 50mm timber
these documents are indicative only and not for construction or certification purposes. Mix.) Proposed topsoil must comply with Australian Standards AS4419-2003 and Australian Standards battens (or composite wood as approved) spaced at 50mm or 100mm spacings as indicated on the drawings.
AS3743-2003 ‘Potting Mixes’ Colour finish to match house colour that it is located next to. Confirm with Architect on site.
D. ELECTRICAL WORKS INFORMATION Provide certification of soil types delivered to site, as per AS3743-2003.
Refer to Electrical Engineer's drawings for all information contained within these documents related to and FENCE TYPE A2: 1500mm fence with 50 x 50mm battens at 50mm spacings fixed atop retaining wall. Colour
TOPSOIL AERATION AND DECOMPOSITION: finish to match house colour that it is located next to. Confirm with Architect on site. ORGANIC MULCH - 1 INCH HOOP BARK INORGANIC MULCH - 'TENTERFIELD PEARL' DECORATIVE BOULDERS
nominated as Electrical Works. Electrical Works information contained within these documents are indicative
and not for construction or certification purposes. Contractor must allow to maintain finished levels allowing for potential slumping and subsidence. Tamping
down and light wetting up of soil during placement on podium to ensure air pockets and voids are managed out. FENCE TYPE B Pool Fence: By others, refer Architects Drawings
E. HYDRAULIC WORKS INFORMATION
Refer to Hydraulic Engineer's drawings for all information contained within these documents related to and FERTILIZER: FENCE TYPE C Proposed Fire Protection Fence: By others, refer Architects Drawings
nominated as Hydraulic Works. Hydraulic Works information contained within these documents are indicative Ensure soil nutrient and PH levels are suitable for specific plant species (ie. native or exotic species)
only and not for construction or certification purposes. Apply appropriate slow release fertilizer (ie. native / exotic species) to each plant as per manufacturer's FENCE TYPE D1 Boundary: 1800mm high fence with 100 x 100mm posts and 100 x 10mm timber capping and
recommended rates. plinth. 100 x 20mm battens to be angled to obscure views through.
A slow or controlled release fertiliser organic or inorganic to be incorporated generally into the imported (or
LANDSCAPE SPECIFICATION NOTES FENCE TYPE D2 Boundary Fence Acoustic: By others, refer Architects Drawings
excavated / site topsoil). We recommend the following:
LEVELS-GENERAL NOTES
Inorganic Slow or Controlled Release fertilisers: FENCE TYPE E Bin Enclosure: 1500 - 1800mm high fence/ gate with 50 x 50mm battens at 50mm spacings.
Finish organic mulch surfaces 25 - 40mm below adjacent paving surfaces and / or edging. Finish lawn surfaces
• Osmocote Height of fence/ gate to be 1800mm for front access and 1500mm high for bin enclosures.
flush with adjacent paving surfaces and / or edging. Ensure adequate falls in finished surface levels away from
• Nutricote
buildings to drainage collection points (eg, field inlets, etc).
• Macrocote ENTRY FEATURE
• E-Scape PRO by eCo-Enviroment
SUBSOIL DRAINAGE - GENERAL NOTES
GENERALLY: Construct a major and two minor signage/ features in the locations as shown on the drawings.
Ensure adequate subsoil drainage elsewhere by installing suitable agricultural drainage systems where
Organic slow release: See indicative images to show materials, design intent and general proportions.
necessary, and especially in areas subjected to site excavation works including retaining walls.
• Dynamic Lifter
• Organic Link by Plant of Health All required fixings, footings, and construction methodology to engineer's / builder's confirmation and
PLANTS Landscape Architect's approval. Final locations, extent and positioning to Landscape Architect's approval and
PLANTING: may require the construction of a plinth to ensure visibility and appropriate finished levels.
• NATSPEC shall apply to trees where Council requires this certification. To locations as shown on the plan and to the sizes and numbers as shown on the schedule.
• Plants are to be good quality nursery stock from a NIASA Accredited nursery MATERIALS: Stone cladding from Eco Outdoor 'Cracken Back' Ph1300 131413. Project logo, lettering font and
• They shall be fundamentally free of pest and diseases. SANDSTONE REGULAR STEPPERS SANDSTONE RANDOM STEPPERS
ORGANIC MULCHING: sizing to be confirmed by project marketing / branding consultant.
• After installation they shall be thoroughly watered. Where specified, proposed mulch must comply with Australian Standards AS4454-2003. 'Composts, soil
conditioners and mulches'. Spread 1" Hoop Bark to a minimum depth of 75mm entirely over planting bed areas.
TURF
DRAINAGE CELLS: STRUCTURE AND BENCH SEATING
SUBGRADE PREPARATION: Use drainage cells to podium planters
Turfed areas shall be prepared initially by removing all deleterious material GENERALLY: Design and construct shelter structure with incporated seat in the location as shown on the
Cultivate subgrade surface by thoroughly ripping to a minimum depth of 150mm before spreading topsoil unless Horizontal Application: drawings. The images and landscape drawings show the extent and design intent and the final finish should be
otherwise directed (ie: no cultivation under trees to be retained) Install VersiCell 30mm (https://elmich.com.au/products/versicell-subsoil-drainage/) or similar drainage cell, coherent with similar elements on site or as discussed with the landscape architect.
installed to manufacturer’s recommendations.
SOIL: Ensure all corners and sharp edges are removed and tapped to avoid damaging the waterproof membrane. The construction methodology, timber sizes, finishing, fixings, wind loading, footings and final design will be
Spread turf underlay topsoil to a minimum depth of 100mm unless otherwise directed. Proposed topsoil must Apply final layer of geofabric/ filter fabric (refer below) over entire drain cell area. Lap material minimum 400mm undertaken by an engineer/ builder to the landscape architects approval.
comply with Australian Standards AS4419-2003 and described as 'Soil blend'. at junctions or joins. Turn fabric up walls and service risers minimum 300mm. Ensure neat holes cut in around
services with minimum 15mm clearance.
TURF: TIMBER GARDEN EDGE
To be fundamentally free from weeds and disease or other deleterious substances. Vertical Application (to planter walls):
• Turf to be Sir Grange (Zeon Zoysia) for all areas within the project designated as 'turf' Install to manufacturer's specifications to all podium planter garden bed walls over 400mm in height. Lapping GENERALLY: Install to the locations as indicated on the drawings.
joins and junctions by minimum 100mm.
Supplier: Refer Lawn Solutions website for local growers https://lawnsolutionsaustralia.com.au/turf-suppliers/ or MATERIAL: Sawn hardwood of Durability Class 1 as defined in Appendix D of AS 1604 or CCA treated
call 1300 883 711. GEOFABRIC: softwood.
Install Filterwrap (https://www.geofabrics.co/products/filterwrap™) as per Geosystems Australia details and SIZE: 3000 x 100 x 15mm nominal edgings, 50mm square pegs, 350mm long.
INSTALLATION: specifications. INSTALLATION: Set edgings flush with adjoining surfaces to define planting, grass areas, pathway edges, etc.
Turf shall be close turfed with staggered cross-joints and laid in straight lines, running perpendicular to the Fix to pegs with galvanized nails, two per fixing. Drive pegs into the ground at 1200-1750mm centres on the turf
direction of slope (and / or parallel to contours). VOID FILLER: side of the edging and on both sides of joints between boards with peg tops 15mm below top of edging. CONCRETE PAVING TYPE 1 DRIVEWAY CONCRETE PAVING TYPE 3 FOOTPATH
Proposed topdressing soil to comply with Australian Standards AS4419-2003 and as described as Install polystyrene blocks cut to size to podium planters as shown on details. Contact Polystyrene Products (or CURVING: Where the timber edge is to be curved, space the pegs to hold it to a uniform curve.
'Topdressing'. similar) for space fillers. Ensure geofabric is installed over, to separate soil media from the polystyrene product.
All joints shall be filled with an approved topdress light soil or sand and the turf shall be lightly rolled. (https://www.polystyreneproducts.com.au) BIO-RETENTION BASIN
Finished levels shall be 3mm below surrounding surface levels to allow for future top dressing. Allowance
should be made for shrinkage and settling. IRRIGATION: Refer to Engineering drawings for bio-retention details. Prior to planting, ensure installation of erosion control
Turf shall be adequately watered once installed, refer Management Plan/s. Ensure irrigation is provided as per specification. matting (ie: Jutmaster Fine by Geofabric Australasia), secured as per manufacturer's recommendations.
Ensure protection from trampling.
SANDSTONE STEPPERS IRRIGATION
FERTILISER:
Fertiliser to be applied to the turf at the rates and period of time from installation as recommended by the GENERALLY: Use natural stone, which is uniform quality in each grade, sound and free from defects liable to Planting plan has been designed to survive without an automatic irrigation system. Water additives and water
supplier. If no starter Fertiliser supplied by the supplier, we recommend: affect its strength. retention elements, along with hardy water-wise plants will ensure an irrigation system is not imperative to the
Dynamic Lifter Turf Starter: long-term maturation and survival of the proposed plants. If approved, install an automatic, fixed position, low
http://www.yates.com.au/products/fertilising/organic-based/dynamic-lifter-turf-starter/ SIZE: Random steppers to average approx. 400mm but varying in size/ shape for visual interest with gap of pressure sprinkler irrigation system to all landscaped areas shown on the drawings internal to the site only, to
#tbCQXOZuFJZ01z1B.97 approx. 150 – 200mm between to allow for planting. Noosa Shire Council approval. The irrigation shall meet the following performance requirements and as per the
Lawn Builder™ Seed & Turf Starter Slow Release Lawn Fertiliser: manufacturers and/or installers specifications:
https://www.scottsaustralia.com.au/scotts-brands/lawn-builder/lawn-builder-slow-release- SIZE: Regular steppers to be 300 x 1500mm min 20mm thickness or equal approved • Summer target application of 32mm
lawn-fertilisers/lawn-builder-seed-turf-starter-slow-release-lawn-fertiliser/ • Fully automatic and metered
SUPPLIER: Sandstone World Ph 0431 285 425 or equal approved. • Recycled water use (from rainwater tanks)
SOIL WETTING AGENT: • Commercial quality fittings and fixtures
We recommend the application of a soil wetting agent wetting agent (ie: non biodegradable detergent not LAYING: Subgrade to be fully compacted before mortar bed is laid. Subgrade shall be compacted 95% of • Mainlines
crystals) to stop hydrophobia if not already in the starter fertiliser supplied with the turf, at the rates medium dry density. Mortar to comply with AS 3700 and match sandstone colour as new. Stone should vary in • Dripline system under mulch
recommended by the manufacturer: size and shape for interest and naturalistic look. • RPZ backflow prevent device
• Scotts Hydraflow Wetta Soil CONCRETE PAVING TYPE 2 ENTRY CONCRETE PAVING TYPE 5 ROADWAY CONCRETE PAVING TYPE 6
• Searle’s Penetraide CONCRETE AND PAVING All design and documentation, materials supplied and work carried out should be in accordance with the current AND TYPE 4 FOOTPATH
• Plant of Health Soils Soaker relevant Australian Standards and best practice.
GENERALLY: Install exposed aggregate and coloured concrete footpaths, driveways and roadways in the
WEEDS, PESTS DISEASE MANAGEMENT locations and to the extents as shown on the drawings. Refer drawings for the locations and extents of the PLANT ESTABLISHMENT / CONTINUING MAINTENANCE
Weeds are required to be removed by physical or chemical (Glyphosate or other herbicides) means. If chemical below types.
means, as per the manufacturer recommendations. Refer to the following reference for guideline on weeds, Allow a 12 WEEK Plant Establishment Period from Practical Completion to the satisfaction of the Landscape
pest and disease management Type 1 Driveway: Boral exposed aggregate to match ‘Black night’ mix or equal approved based on supplied Architect.
REFERENCE: sample. Level of exposure to be determined following sample. • Maintain adequate watering regime
http://thelawnguide.com.au • Remove weed growth from all mass planting beds and turfed areas
Type 2 Entry: Portland grey standard concrete trowel finish. Approval based on supplied sample. Not float • Fertilise (as per the notes above) G 02/09/22 UPDATED ARCHITECTURAL DWGS
PLANTING BEDS edges. Trowel finish to be even across whole pour section. • Weed control (as per the notes above) F 18/02/20 IN RESPONSE TO NC IR
• Prune planting, control pest and disease management (as per the notes above) to maintain healthy growth E 12/07/19 UPDATED ISSUE FOR TENDER
SUBGRADE PREPARATION: Type 3 Footpath: CCS Full depth coloured concrete sand colour or equal approved based on supplied sample. • Replenish mulch material where necessary D 10/07/19 COORDINATION ISSUE
Cultivate subgrade surface by thoroughly ripping to a minimum depth of 150mm before spreading topsoil. • Replace dead / dying plant material
Type 4 Footpath: Portland grey standard concrete trowel finish. Approval based on supplied sample. Not float • Reinstate stakes, ties and marker stakes where necessary ISSUE DATE REASON
TOPSOIL: edges. Trowel finish to be even across whole pour section. • Reinstate erosion control matting and other erosion control measures as necessary
Spread topsoil to a minimum depth of 300mm unless otherwise directed. Proposed topsoil must comply with
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
Australian Standards AS4419-2003 and described as 'Soil blend'. Type 5 Roadway: CCS Full depth coloured concrete ‘Black 44’ or equal approved based on supplied sample. Continue maintenance works beyond Plant Establishment Period as required. AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
Provide certification of soil types delivered to site, as per AS4419-2003. Depth and construction detail of roadway to engineer’s detail. INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
MANAGEMENT PLAN/S:
RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
FERTILIZER: Type 6: Open jointed pavers located within the lots to be 400 x 400 x 40mm paver to match Boral Exposed ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
A slow or controlled release fertiliser organic or inorganic to be incorporated generally into the imported (or aggregate ‘Coral Coast’ or equal approved based on supplied sample . The turfed areas shall be throughly watered on the day of turf installation and then as follows at the equivalent DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
excavated / site topsoil). We recommend the following: of 5l/m², including natural rainfall, or as required to maintain active healthy growth. INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
Inorganic Slow or Controlled Release fertilisers: Supplier: Exposed aggregate mixes to be Boral Ph 1300 305 980 and coloured concrete pigment to be CCS FENCE TYPE A1 FENCE TYPE D1 FENCE AND GATE TYPE E FENCE AND GATE TYPE E
• Osmocote (Concrete colour systems) Ph 1800 077 744 Weeks 1-3: Twice a week
• Nutricote Weeks 3-12: Once a week or as necessary
• Macrocote Joints: Construct joints in the patterning as shown on the drawings. Approximate locations of joints shown.
• E-Scape PRO by eCo-Enviroment Adjust accordingly to suit engineer’s requirement of frequency and types. If no irrigation, apply the above rates to the mass planting beds. Watering to use rainwater tanks if possible.
Organic slow release: DECORATIVE BOULDERS SPECIAL NOTE
• Dynamic Lifter
• Organic Link by Plant of Health GENERALLY: Place and secure decorative boulders in the locations as indicated on the drawings. Boulders to Accord particular diligence to the following prime items:
be placed in a naturalistic and artistic arrangement.
WETTING AGENT: TOPSOIL QUALITY and SUBGRADE PREPARATION as specified.
ESSENCE OF PEREGIAN BEACH
A wetting agent and / or soil ameliorant including a wetting agent is required to all mass planting beds:
• Scotts Hydraflow Wetta Soil
MATERIALS: Boulders to range in size and vary between 400 x 400, 600 x 600 and 900 x 900 depending on
the locations and availability. Source boulders to match with sandstone and gravel materials. PLANT QUANTITY: Use only consistently well nurtured nursery stock from an approved supplier. Check with
215 DAVID LOW WAY, PEREGIAN BEACH
• Searle’s Penetraide Plant of Health Soils Soaker Landscape Architect where species substitutions must be made.
• Multipro by eCo-Enviroment GRAVEL TO FOOTPATH
PLANTING: GENERALLY: Install feature gravel to a minimum of 75mm in the locations as indicated on the drawings.
MAINTENANCE: Ensure a continuing maintenance program, including weed/disease, fertilising, watering (but
beware of over-watering) and replacement of ailing plant material.
LANDSCAPE WORK NOTES
As indicated on plan. MATERIAL: Gravel to be Tenterfield Pearl 20-40mm subject to sample.
GUARANTEE
ORGANIC MULCHING - BULK PLANTING AREAS SUPPLIER: Centenary Landscape Supplies Ph (07) 3373 4999 or equal approved. Failure to adequately address these items, best practice and relevant Australian Standards WILL result in a
sub-standard landscape outcome.
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
GENERALLY: Proposed mulch must comply with Australian Standards AS4454-2003. 19.021 1 G CP/NB AG/NC
MATERIAL: Spread 1" Hoop Bark to a minimum depth of 100mm entirely over planting bed areas as indicated
on the drawings. STRUCTURE AND BENCH SEATING SHELTER STRUCTURE
NOT FOR CONSTRUCTION
Section 3
PLANTING SCHEDULE
The spacing of plants shown on plan have been derived as a compromise between growth rate, anticipated size, and the ability to provide a good vegetative cover within a reasonable space of time. Quantities indicated have been based on the spacing of individual plants appropriate to the
available area for the particular species used; where this available area increases (or decreases) through the course of construction, quantities may also need to increase (or decrease) to maintain the plant spacings indicated on plan.
CODE SPECIES COMMON NAME SIZE** QUANTITY SPACING HEIGHT* WIDTH*
TREES BIORETENTION PLANTING TYPE 1 ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
Ba Backhousia citriodora Lemon Scented Myrtle 100L 4 as shown 8 4 Carex appressa Tall Sedge Tube 204 6 per m² MT GRAVATT EAST
QLD 4122
Ca Cupaniopsis anacardioides Tuckeroo 100L 17 as shown 15 8 Ficinia nodosa Knobby Club Rush Tube 204 6 per m²
Ht Hibiscus tiliaceus Cottonwood 100L 3 as shown 8 6 Juncus usitatus Common Rush Tube 204 6 per m² T 07 3420 0006
M 0405 389 243
HR Hibiscus tiliaceus Rubra Red Cottonwood 100L 17 as shown 8 5 Lomandra longifolia Mat Rush Tube 204 6 per m² E [email protected]
Tl Tristaniopsis laurina Luscious Water Gum 100L 56 as shown 10 5 Total: 816
BIORETENTION PLANTING TYPE 2
PALMS
Ficinia nodosa Knobby Club Rush Tube 146 6 per m²
Hf Howea forsteriana Kentia Palm 100L 13 as shown 10 6 Juncus usitatus Common Rush Tube 146 6 per m²
Pt Pandanus tectorius Screw Pine 200L 9 as shown 5 5 Myoporum parvifolium Creeping Boobialla 140mm 146 6 per m²
Pe Ptychosperma elegans Solitaire Palm 200L 20 as shown 8 5 Total: 438
SCREEN PLANTING
*HEIGHT AND WIDTH: MINIMUM STOCK SIZES
MET tom Metrosideros thomasii Christmas Bush 300mm 31 2.5 4-6 5
Heights and widths as shown are at full maturation, indicative only and dependent on The recommended minimum plant size relative to the container size is as follows. Should the stem calliper of
RHA exc Rhapis excelsa Broadleaf Lady Palm 250mm 16 0.8 2 1.2
environmental and microclimatic factors height of the tree relative to the container size be less than the figures shown, the tree should be rejected.
SYZ BB Syzygium australe Baby Boomer Lillypilly 200mm 77 1.2 1.5 1.5
** PLANT CONTAINER SIZE: Root ball volume Height (above container) Calliper (at 300mm) Clean trunk height
SHRUBS 400L 400 Litre container stock min Min. height at time of planting: 3m 45 litre 1.9 - 2.3 metres 30mm - 35mm 1200mm
200L 200 Litre container stock min Min. height at time of planting: 3m 75 litre 2.2 - 2.4 metres 40mm - 45mm 1400mm
BAE vir Baeckea virgata Dwarf Twiggy Heath Myrtle Dwarf 200mm 90 0.4 0.3 0.5 100L 100 Litre container stock min Min. height at time of planting: 2.5m 100 litre 2.4 metres 50mm 1500mm
CAL RR Callistemon Rocky Rambler Bottlebrush 140mm 71 0.9 0.5 1 - 1.5 45L 45 Litre container stock min Min. height at time of planting: 1.8m 200 litre 3.6 metres 60mm 1500mm
CAR gra Carissa grandiflora Desert Star Desert Star 200mm 291 0.7 1 1 25L 25 Litre container stock min Min. height at time of planting: 1m 300 litre 4.2 metres 70mm 1500mm
CAS gla Casuarina glauca Green Wave Casuarina Green Wave 140mm 85 1 1-2 1-2 300mm 300mm dia minimum pot size 400 litre 5.5 metres 70mm 1500mm
LOM hys Lomandra hystrix Mat Rush 140mm 249 1 1.8 1.5 200mm 200mm dia minimum pot size Palm trees NA NA 5 metres clear
LOM lon Lomandra longifolia Mat Rush 140mm 7 0.8 1.2 1.2 140mm 140mm dia minimum pot size trunk
MON cap Molineria capitulata Palm grass 200mm 5 0.9 1 1 Tube 50x50x125mm deep tubestock
OZO dio Ozothamnus diosmifolius Rice Flower 140mm 89 1.2 1-5 1 - 1.5
PHI xan Philodendron Xanadu Xanadu 200mm 14 0.8 1 1
VIB EL Viburnum odoratissimum Emerald Lustre Sweet Viburnum 200mm 100 1.2 3-4 1.5
WES fru Westringia fruiticosa Coastal Rosemary 140mm 26 1.2 0.3 1-2
WES WG Westringia Wynyabbie Gem Native Rosemary 200mm 397 0.7 0.9 0.8
WES Z Westringia Zena Dwarf Rosemary 200mm 6 0.9 1 1
ZAM zam Zamioculcas zamiifolia Zanzibar Gem 200mm 44 0.4 0.8 0.5
GROUNDCOVERS
CAR gla Carpobrotus glaucescens Aussie Rambler Pigface 140mm 75 1.5 0.2 2
CAS CI Casuarina glauca Cousin It Prostrate Casuarina 140mm 30 1 0.3 1.5
CIS ED Cissus Ellen Danica Grape Ivy 140mm 25 1.8 0.3 2.5 - 3
DIA bre Dianella brevipedunculata Blue Flax Lily 140mm 164 0.5 0.5 0.5
GAZ rig Gazania rigens White White Gazania 140mm 74 0.9 0.2 - 0.4 0.5 - 1
LOM ver Lomandra Verday Dwarf Lomandra 140mm 276 0.5 0.5 0.6
MYO par Myoporum parvifolium Creeping Boobialla 140mm 66 1.2 0.3 [email protected] ccs
MYO par Myoporum parvifolium Creeping Boobialla 140mm 90 1.0 0.3 1.5
SCA aem Scaevola aemula Aussie Crawl Fan Flower 140mm 49 0.8 0.4 - 0.5 0.5 - 1
VIO hed Viola hederacea Native Violet 140mm 97 1 0.15 2
WES BCC Westringia bulli Coastal Creeper Prostrate Native Rosemary 175mm 149 1.5 0.2 2
@ 1m ccs
WES BCC Westringia bulli Coastal Creeper Prostrate Native Rosemary 175mm 36 1.5 0.2 2
WES M Westringia Mundi Coastal Rosemary 140mm 34 0.5 0.25 0.6
GRASSES
FIN nod Ficinia nodosa Knobby Club Rush 140mm 43 0.6 1 0.8
LOM LL Lomandra Little Lime Little Lime Mat Rush 140mm 592 0.4 0.5 0.5
FEATURE PLANT
ASP ant Asplenium antiquum Birds Nest Fern 300mm 49 1.2 1 1.5
CRI ped Crinum pedunculatum Swamp Lily 200mm 11 1.5 2 2
CLIMBERS
HAR vio Hardenbergia violacea White Out False Sarsaparilla 300mm 11 as shown - - G 02/09/22 UPDATED ARCHITECTURAL DWGS
F 18/02/20 IN RESPONSE TO NC IR
E 12/07/19 UPDATED ISSUE FOR TENDER
D 10/07/19 COORDINATION ISSUE
PODIUM PLANTING
ISSUE DATE REASON
AGA att Agave attenuata Centenary Plant 300mm 12 1 1 1
CAS CI Casuarina glauca Cousin It Prostrate Casuarina 200mm 10 1 0.3 1.5 THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
COT orb Cotyledon orbiculata Dan’s Delight Cotyledon Dan’s Delight 200mm 21 0.5 0.6 0.5 INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
CRA ova Crassula ovata Jade Plant 200mm 6 0.5 0.6-1 0.3-0.6 RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
EUP acr Euphorbia acruensis Cowboy Cowboy Cactus 300mm 12 0.8 1.5 1.8 ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
FIC pul Ficus pumila Climbing Fig 200mm 5 as shown 6 6 INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
HEL HRN Heliconia bihai x caribaea Hot Rio Nights Parrot's Beak 300mm 3 1.2 3-4 1.5
MES cor Mesembryanthemum cordifolia Baby Sunrose 200mm 65 0.8 0.2 1
PHI xan Philodendron Xanadu Xanadu 200mm 6 0.8 1 1
ZAM zam Zamioculcas zamiifolia Zanzibar Gem 200mm 45 0.4 0.8 0.5
ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
PLANTING SCHEDULE
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 2a G CP/NB AG/NC
NOT FOR CONSTRUCTION
Section 4
TREES PALMS
ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
QLD 4122
T 07 3420 0006
M 0405 389 243
E [email protected]
Backhousia citriodora Cupaniopsis anacardioides Hibiscus tiliaceus Howea forsteriana Pandanus tectorius
Lemon Scented Myrtle Tuckeroo Cottonwood Kentia Palm Screw Pine
Hibiscus tiliaceus 'Rubra' Tristaniopsis laurina Luscious Ptychosperma elegans
Red Cottonwood Water Gum Solitaire Palm
SCREENING SHRUBS SHRUBS GROUNDCOVERS PODIUM PLANTING
Metrosideros thomasii Rhapis excelsa Baeckea virgata Dwarf Callistemon Rocky Rambler Carissa grandiflora Desert Star Carpobrotus glaucescens Aussie Rambler Casuarina glauca Cousin It Cissus Ellen Danica Agave attenuata Casuarina glauca Cousin It
Christmas Bush Broadleaf Lady Palm Twiggy Heath Myrtle Dwarf Bottlebrush Desert Star Pigface Prostrate Casuarina Grape Ivy Centenary Plant Prostrate Casuarina
Syzygium australe Baby Boomer Casuarina glauca Green Wave Lomandra hystrix Lomandra longifolia Dianella brevipedunculata Gazania rigens White Lomandra Verday Cotyledon orbiculata Dan’s Delight Crassula ovata
Lillypilly Casuarina Green Wave Mat Rush Mat Rush Blue Flax Lily White Gazania Dwarf Lomandra Cotyledon Dan’s Delight Jade Plant
GRASSES
Ficinia nodosa Lomandra Little Lime Molineria capitulata Ozothamnus diosmifolius Philodendron Xanadu Myoporum parvifolium Scaevola aemula Aussie Crawl Viola hederacea Euphorbia acruensis Cowboy Ficus pumila G 02/09/22 UPDATED ARCHITECTURAL DWGS
Knobby Club Rush Little Lime Mat Rush Palm grass Rice Flower Xanadu Creeping Boobialla Fan Flower Native Violet Cowboy Cactus Climbing Fig F 18/02/20 IN RESPONSE TO NC IR
E 12/07/19 UPDATED ISSUE FOR TENDER
D 10/07/19 COORDINATION ISSUE
FEATURE PLANT
ISSUE DATE REASON
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
Asplenium antiquum Crinum pedunculatum Viburnum odoratissimum Emerald Lustre Westringia fruiticosa Westringia Wynyabbie Gem Westringia bulli Coastal Creeper Westringia Mundi Heliconia bihai x caribaea Hot Rio Nights Mesembryanthemum cordifolia
Birds Nest Fern Swamp Lily Sweet Viburnum Coastal Rosemary Native Rosemary Prostrate Native Rosemary Coastal Rosemary Parrot's Beak Baby Sunrose
CLIMBERS
ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
PLANTING IMAGES
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
Hardenbergia violacea White Out
False Sarsaparilla
Westringia Zena
Dwarf Rosemary
Zamioculcas zamiifolia
Zanzibar Gem
Philodendron Xanadu
Xanadu
Zamioculcas zamiifolia
Zanzibar Gem
19.021 2b G CP/NB AG/NC
NOT FOR CONSTRUCTION
Section 5
RETAIN ALL EXISTING VEGETATION TO LANEWAY 2m CONCRETE FOOTPATH PROPOSED PLANTER WALL
Protect from construction impacts Refer Specification Notes Blockwork 800mm high
RUFOUS STREET
Refer Specification Notes and Detail
3.0
3.0
3.0
RUFOUS LANE 900 DIA 900 DIA
ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
TE
TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE QLD 4122
DIA
TE
900
T 07 3420 0006
POOL RECREATIONAL BUILDING AND SHELTER M 0405 389 243
TE
TE
10 KAMALA 11 WALLUM 13 WALLUM 14 WALLUM 16 WALLUM E [email protected]
Refer Architectural drawings
TE
TE
TE
TE
TE
TE
TE
TE
15 MARRAM
TE
TE
TE
12 MARRAM LEGEND
TE
POOL
TE
TE
9 LILY
TE
TE
TE
PROPERTY BOUNDARY
TE
TE
TE
As taken from Survey drawings
TE
TE
BIO-RETENTION BASIN
TE
TE
TE
TE
Refer Civil Engineering drawings PROPOSED RETAINING WALL
TE
TE
TE
TE TE TE
Refer Engineering drawings
PROPOSED CONTOURS
As taken from Civil Engineering drawings
6.0
5.5
5.0
4.5
6.5
EXISTING / PROPOSED SEWER
/
As taken from Survey / Engineering drawings
TE TE
EXISTING / PROPOSED STORMWATER
/
PROPOSED FENCE ON TOP OF
TE
TE TE
RETAINING WALL As taken from Survey / Engineering drawings
TE
4.5
Refer Civil Engineering drawings PEREGIAN BEACH
TE
TE
TE
17 SALTBRUSH 1 HOTEL EXISTING TREES - REMOVED
TE
/ 8 LILY As taken from Survey plans
TE
TE
EXISTING TREES TO RESERVE
TE
TE
TE
TE
6.5
Protect from construction impacts 6 MARRAM
SANDSTONE REGULAR STEPPERS
TE
TE
/
TE TE
TE
TE
Refer Specification Notes
TE
7 KAMALA
5 KAMALA
TE
TE
TE
TE
/
TE TE TE TE TE TE TE TE TE SANDSTONE RANDOM STEPPERS
TE
TE TE TE
18 SALTBRUSH 2 Refer Specification Notes
TE
POOL RECREATIONAL BUILDING TE TE TE TE TE TE TE TE TE
TE
TE
Refer Architectural drawings
TE
TE
/
4 KAMALA PROPOSED TIMBER GARDEN EDGE
TE
TE TE
PROPOSED HARDSTAND 1 KAMALA Refer Specification Notes and Detail
TE
TE
TE TE TE
8.0
Refer Architectural drawings
TE
2 MARRAM
TE
3 MARRAM
6.5
TE
/
BUILDING / ROOF OVER
TE
TE
Refer Architectural drawings
TE
TE
PROPOSED POOL FEATURE STRUCTURE POOL
TE
Refer Architectural drawings 19 SALTBRUSH 1
TE
/
PROPOSED TURFED AREAS
TE
TE
TE
Refer Specification Notes
TE
TE
/
TE TE TE
PROPOSED MULCHED PLANTING AREAS
6.0
Refer Specification Notes
/
PROPOSED GRAVEL PLANTING AREAS
STORMWATER DETENTION TANK
20 SALTBRUSH 2 Refer Specification Notes
UNDER AND PLANTING OVER
5.5
5.0
Refer Engineering drawings
/
PROPOSED / EXISTING EASEMENT
Refer Achitectural drawings
BIN WASHDOWN &
GARDEN EQUIPMENT STORE
900 DIA
PROPOSED BIO-RETENTION BASIN
Refer Specification Notes and
900 DIA
/
EASEMENT
PROPOSED HOTEL Proposed Planting Schedule
COUNCIL
/
EXISTING LANDSCAPE
RESERVE
Protect from construction impacts
SEWER EASEMENT
Redirected sewer
/
/ PROPOSED SAFETY FENCE
Refer Engineering drawings
MINOR ENTRY SIGNAGE / FEATURE EXISTING SPECIALTY SHOPS
Refer images for indicative concept
//
MINOR ENTRY SIGNAGE / FEATURE
EXISTING IGA 2m CONCRETE FOOTPATH
Refer images for indicative concept
Refer Civil Engineering drawings
DAVID LOW WAY
/
EXISTING LANDSCAPE TREATMENT
Protect from construction impacts PROPOSED ACCESS GATE
Provide new access gate to match existing
NOTE:
/
EMERGENCY EGRESS ROAD For surface finishes, refer separate plans
For fences, gates and screens, refer separate plans
/
EASEMENT
MASONRY BLOCK SCREEN FENCE G 02/09/22 UPDATED ARCHITECTURAL DWGS
To bin store, refer Architectural drawings F 18/02/20 IN RESPONSE TO NC IR
E 12/07/19 UPDATED ISSUE FOR TENDER
/
D 10/07/19 COORDINATION ISSUE
ISSUE DATE REASON
/
ENERGEX PMT SITE LOCATION THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
Refer Architectural drawings AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
PROPOSED RETAINING WALL
/
PEREGIAN VILLAGE MARKETS INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
Refer Civil Engineering drawings RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
/
DIMENSIONS ARE TO BE VERIFIED ON SITE.
GRAPHIC SCALE (m) 1:300 @ A1
0 1 5 10 15
BUSHFIRE SETBACK ZONE
ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
OVERALL LANDSCAPE PLAN
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 3 G AL/CP AG/NC
10.0
5.0
6.0
7.0
8.0
9.0
ENERGEX HV / LV CABLE AND CONDUIT PIT MAJOR ENTRY SIGNAGE / FEATURE
Refer Architectural drawings Refer images for indicative concept
NOT FOR CONSTRUCTION
Section 6
2m CONCRETE FOOTPATH
Refer Specification Notes
RUFOUS STREET
3.0
3.0
3.0
RUFOUS LANE ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
TE
TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE QLD 4122
TE
T 07 3420 0006
POOL RECREATIONAL BUILDING AND SHELTER M 0405 389 243
TE
TE
10 KAMALA 11 WALLUM 13 WALLUM 14 WALLUM 16 WALLUM E [email protected]
Refer Architectural drawings
TE
TE
TE
TE
TE
TE
TE
TE
15 MARRAM
TE
TE
TE
12 MARRAM LEGEND
TE
POOL
TE
TE
9 LILY
TE
TE
TE
PROPERTY BOUNDARY
TE
TE
TE
As taken from Survey drawings
TE
TE
BIO-RETENTION BASIN
TE
TE
TE
TE
Refer Civil Engineering drawings PROPOSED RETAINING WALL
TE
TE
TE
TE TE TE
Refer Engineering drawings
PROPOSED CONTOURS
As taken from Civil Engineering drawings
6.0
5.5
5.0
4.5
6.5
EXISTING / PROPOSED SEWER
/
As taken from Survey / Engineering drawings
TE TE
EXISTING / PROPOSED STORMWATER
/
PROPOSED FENCE ON TOP OF
TE
TE TE
RETAINING WALL As taken from Survey / Engineering drawings
TE
4.5
Refer Civil Engineering drawings PEREGIAN BEACH
TE
TE
TE
17 SALTBRUSH 1 HOTEL SANDSTONE REGULAR STEPPERS
TE
/ 8 LILY Refer Specification Notes
TE
TE
TE
TE
TE
TE
6.5
6 MARRAM
TE
SANDSTONE RANDOM STEPPERS
TE
/
TE TE
TE
TE
TE
7 KAMALA Refer Specification Notes
5 KAMALA
TE
TE
TE
TE
PROPOSED TIMBER GARDEN EDGE
/
TE TE TE TE TE TE TE TE TE TE
TE
TE TE TE
18 SALTBRUSH 2 Refer Specification Notes and Detail
TE
POOL RECREATIONAL BUILDING TE TE TE TE TE TE TE TE TE
TE
TE
Refer Architectural drawings
TE
TE
/
4 KAMALA BUILDING / ROOF OVER
TE
TE
PROPOSED HARDSTAND 1 KAMALA Refer Architectural drawings
TE
TE
TE TE TE
8.0
Refer Architectural drawings
TE
2 MARRAM
TE
3 MARRAM
6.5
TE
/
FENCE TYPE A1 (100mm spacing)
TE
TE
Refer Specification Notes and Detail
TE
TE
PROPOSED POOL FEATURE STRUCTURE
TE
Refer Architectural drawings POOL 19 SALTBRUSH 1
TE
/
FENCE TYPE A1 (50mm spacing)
TE
TE
TE
Refer Specification Notes and Detail
TE
TE
/
TE TE TE
FENCE TYPE A1 (1800mm high)
6.0
Refer Specification Notes and Detail
/
FENCE TYPE A2
STORMWATER DETENTION TANK
20 SALTBRUSH 2 Refer Specification Notes and Detail
UNDER AND PLANTING OVER
5.5
5.0
Refer Engineering drawings
/
FENCE TYPE B POOL FENCE
By others, refer Architectural drawings
BIN WASHDOWN &
GARDEN EQUIPMENT STORE
FENCE TYPE C FIRE PROTECTION FENCE
By others, refer Architectural drawings
/
EASEMENT
PROPOSED HOTEL
FENCE TYPE D1 BOUNDARY FENCE
COUNCIL
Refer Specification Notes and Detail
/
RESERVE
FENCE TYPE D2 BOUNDARY FENCE ACOUSTIC
/
By others, refer Architectural drawings
SEWER EASEMENT
Redirected sewer
EXISTING SPECIALTY SHOPS FENCE TYPE E BIN ENCLOSURE /
/
FRONT ACCESS
Refer Specification Notes and Detail
EXISTING IGA
/
/ PROPOSED SAFETY FENCE
2m CONCRETE FOOTPATH
Refer Engineering drawings
Refer Civil Engineering drawings
DAVID LOW WAY
/
PROPOSED ACCESS GATE
Provide new access gate to match existing
NOTE:
/
EMERGENCY EGRESS ROAD For surface finishes, refer separate plans
/
EASEMENT
MASONRY BLOCK SCREEN FENCE G 02/09/22 UPDATED ARCHITECTURAL DWGS
To bin store, refer Architectural drawings F 18/02/20 IN RESPONSE TO NC IR
E 12/07/19 UPDATED ISSUE FOR TENDER
/
D 10/07/19 COORDINATION ISSUE
EXISTING FENCE ISSUE DATE REASON
To remain
/
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
PROPOSED RETAINING WALL
/
PEREGIAN VILLAGE MARKETS INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
Refer Civil Engineering drawings RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
/
DIMENSIONS ARE TO BE VERIFIED ON SITE.
GRAPHIC SCALE (m) 1:300 @ A1
0 1 5 10 15
BUSHFIRE SETBACK ZONE
ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
PROPOSED FENCES PLAN
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 4 G AL/CP AG/NC
10.0
5.0
6.0
7.0
8.0
9.0
NOT FOR CONSTRUCTION
The text continues on section 7.