Appendix A - Proposal Plans
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn GENERAL NOTES Note: Allow for ducted air-conditioning.
The builder is responsible to check all Toilets: minimum 4-star dual flush, as rated All electrical appliances and plumbing symbols
existing services prior to beginning any under the Water Efficiency and Labeling are diagrammatical. Refer to builders
construction. Standards scheme (WELS). specification for details all fixtures.
NORT
# Denotes cavity slider to manufactuers Tapware: minimum 3-star WELS rated for Seal wet areas in accordance with N.C.C. Vol. 2.
specification, frames containing cavity sliders kitchen sinks, basins and laundry troughs. Part 3.8.1. Slope floor surface towards fw
to be 90mm minimum U.N.O (floor wastes)
H
Showerheads: minimum 3-star WELS rated Provide lighting in accordance with N.C.C. Vol. 2.
Builder to verify all dimensions prior to showerheads. Part 3.8.4.2 & 3
beginning construction work. Provide ventilation in accordance with N.C.C.
SD Smoke alarms complying with AS 3786 Vol. 2. Part 3.8.5
Electric HWS to minimum energy efficiency to be installed and connected to consumer Mechanical ventilation in accordance with N.C.C
regulations. mains power in accordance with NCC part Vol. 2. and AS1668.2
3.7.2
Planter box Planter box
with step light. 1.8m Timber Fence over retaining wall. with step light.
Splashproof fence required Splashproof fence required
Gate
Gate
Clothes line Clothes line
Gate
Gate
07165 fg 0705 lvr 1200mm Pool fence min
fence + gate
Services
1.2 m pool
Bin Storage
Courtyard Courtyard Area.
Storage
Storage
Dn Dn
Landscaping line of floor over line of floor over Pool Gate
820 Glass 4.6m x 2.5m
1.8m Timber Fence over retaining wall.
line of floor over 820 Glass1505 lvr
Pool 1505 lvr 820 Glass 820 Glass
07165 fg 0705 lvr
720 (U.S)
Pty Br dr dr Br Pty
5.8m x 2.3m
Store
Coupled unit
wm wm
Coupled unit
1200mm Pool fence min
FRL 60/60/60
Landscaping
Ldy Ldy
Garage Garage
Kit 820 Linen -350mm below -350mm below Linen Kit
residence FFL residence FFL 820
c/s (U.S)
720 cs
Pdr
720
720
720
fr Dn Dn Pdr fr 1200mm Pool fence min
Gate
2106 lvr
UP feature wall feature wall UP
Louvre - fixed glass combo
Foyer line of floor over Foyer
1200mm Pool fence min
line of floor over
Landscaping Dining Unit A Unit B
2436 bi fold
900
2118 fg
900
Letterbox
2700 Ceiling 920
Visitor
2206 lvr 2212 fg 2206 lvr
2400 Joinery line of floor over 2151 pl 2127 pl
Select laser cut screen Select laser cut screen
line of floor over Outdoor
Lift Well Entry with floor lighting with floor lighting Entry Living
Entertainment
2106 lvr
Dining 2700 Ceiling
Transition pool fence 1200mm Pool fence min 2400 Joinery UNO
Vo Exhaust fan and
Ramp
Ramp
id o rangehood over
Gate BBQ ve
r
Exhaust fan and Driveway tv BBQ
rangehood over
5406 fg Landscaping
Outdoor
2427 bi fold
Living
Entertainment
Easement Line
Electric sliding gate
5406 fg
e r
ov
id
Vo
Bulkhead Bulkhead
line of deck over Window Seat tv Window Seat Driveway
1809 lvr Bin Storage 1809 lvr
Landscaping Landscaping
Gate
Landscaping Landscaping Landscaping Landscaping
1.8m Timber Fence over retaining wall.
UNIT A - G.F. AREAS UNIT B - G.F. AREAS
Ground Floor Residence : 84.9m²
Ground Floor Residence :
Entry :
105.9m²
1.7m²
PROPOSED DUPLEX GROUND FLOOR PLAN Entry : 1.7m²
Outdoor Entertaining : 24.2m² Outdoor Entertaining : 13.5m²
Ground Floor Total : 131.8m² Ground Floor Total : 100.1m²
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: The Property Clinic - Sunanda Ghosh
Sheet Number: 03 Project Number:19-001
Revision Number Revision Description Revision Date Issued by Project Address: No. 14 Ann Street, Noosaville
1 PCD 7 27/02/2019 BJH
Climate Zone: 2
2 PCD 8 10/04/2019 BJH
Wind Category: To engineers spec.
Ground Floor Plan
Email: [email protected] 3 PCD 9 11/04/2019 BJH
Website: www.iconbuildingdesign.com.au 4 PCD 10 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: PCD 10 Scale: 1 : 100
Phone: 07 54932790 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 1262211