Appendix A - Proposal Plans
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Glass balustrade front fixed with fine
aluminium top rail to manufaturers detail.
Scyon Axon 400 (Or similar)
Select feature wall tiles to cladding to manufacturers detail.
manufacturers specifications.
Custom Aluminium hood to
manufacturers detail.
Framed extrusion to engineers detail
with select aluminum cladding over.
Select Aluminium louvres to
manufacturers detail.
Ceiling Height
6880 -Max. Building Height
2700
Joinery
Colorbond Trimdek roof sheeting
2400
fixed to manufacturers specification
for wind category. (15° pitch).
Framed window feature.
Selected aluminium cladding
to manufacturers detail.
Ceiling Height
2700
Joinery
2400
Rendered 200 series built up
blockwork to engineers detail.
Approx. existing ground line
at front boundary.
PROPOSED NORTH ELEVATION
Colorbond trimdek roof sheeting
fixed to manufacturers specification Colorbond Trimdek roof sheeting Colorbond Trimdek roof sheeting Scyon Axon 400 (Or similar)
for wind category. (5° pitch). fixed to manufacturers specification fixed to manufacturers specification cladding to manufacturers detail.
Aluminum framed windows for wind category. (10° pitch). for wind category. (5° pitch).
to manufacturers specification. Colorbond slotted gutter, fascia to match
Frameless glass balustrade with aluminium roofing. Fix to manufacturers specification.
handrail in accordance with NCC regulations
fixed to manufacturers specification.
Custom Aluminium hood to
manufacturers detail.
Select Aluminium louvres to
Ceiling Height
manufacturers detail.
2700
Joinery
2400
Ceiling Height
2700
Joinery
2400
Rendered 200 series built up
blockwork to engineers detail.
PROPOSED EAST ELEVATION
Approx. Existing Ground Line.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: The Property Clinic - Sunanda Ghosh
Sheet Number: 05 Project Number:19-001
Revision Number Revision Description Revision Date Issued by Project Address: No. 14 Ann Street, Noosaville
1 PCD 7 27/02/2019 BJH
Climate Zone: 2
2 PCD 8 10/04/2019 BJH
Wind Category: To engineers spec.
Elevations
Email: [email protected] 3 PCD 9 11/04/2019 BJH
Website: www.iconbuildingdesign.com.au 4 PCD 10 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: PCD 10 Scale: 1 : 100
Phone: 07 54932790 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 1262211