Original source · versioned page text
4. Attachment C - Traffic Response
Attached to the e-mail Response to Information Request - MCU16/0084 & OPW16/0157.
PRO REV DESCRIPTION BY DATE
BUTTON
THRESHOLD
RAMP 1:14
SERVICES
RISER
JECT A
B
PRELIMINARY ISSUE (CONCEPT 1)
CANOPY EQUIPMENT AND ACCESS REVISED
JB
JB
20.06.16.
21.06.16.
2640 7090 7590 AVE
NUE
1740 6520 350 LOADING
5840
400 AREA PROPOSED CARPARKING PROPOSED CARPARKING
1 11
1370 4100 180
19M B-DOUBLE KW mm
EXISTING TRANSFORMER
BRIDGING CANOPY
Tractor Width : 2500 Lock to Lock Time : 6.0
Trailer Width : 2500 Steering Angle : 23.5
Tractor Track : 2500 Articulating Angle : 70.0
Trailer Track : 2500
SITE BOUNDARY
E
OIN ZON
STAFF PARKING
STAFF PARKING
IL OUS
T
RD
PROPOSED CANOPY ABOVE
P
8mm
L
788
ZA
SITE BOUNDARY
SITE BOUNDARY
FILL POINT m F
H A
NO
4
STOPPING
PASSING LANE
STATUS
AREA : 23.5
PRELIMINARY
AREA: 5.0
: 4.7
NOT FOR CONSTRUCTION
AREA
ATG WARNING
ADJACENT FOOD DRAWINGs NOT TO BE SCALED OFF
PROPOSED RETAIL BUILDING Bin
Coffee
Black & White PARTNER ARE NOT TO BE USED FOR CONSTRUCTION.
- COLES EXPRESS One
Refrigerated
Sandwich
SHOP Cabinet
ACCESS AREA : 6.1
Refrigerated Donut
Cabinet
WARNING
Microwave under
Heated Pie
Cabinet ROAD WIDTHS ARE INDICATIVE ONLY AND
ARE NOT TO BE USED FOR CONSTRUCTION
PURACEPTOR
DOOR
RELEASE
BUTTON SERVICES
RISER
THRESHOLD
RAMP 1:14
LOADING
AREA PROPOSED CARPARKING PROPOSED CARPARKING
16
PROPOSED CARPARKING NOTE:
12 1 11
PROPERTY DIMENSIONS TO BE
CONFIRMED WITH SITE SURVEY,
AIR & INCLUDING OPEN DRAIN AND
PROPOSED CARPARKING
BRIDGING CANOPY
VENTS WATER
EXISTING TREES & VEGETATION.
PROPOSED 7M NOTE:
PYLON SIGN
ROAD MARKINGS ARE APPROXIMATE
INT ZONE
SITE BOUNDARY
& SHOULD BE TREATED AS SUCH.
ILL OUS
MODIFIED EXISTING
MODIFY CROSSING FOR
O
RD
CROSSOVER PROPOSED CANOPY ABOVE
P
SAFE TRUCK ACCESS 8mm
788
ZA
(ENTRY ONLY) NOTE:
SITE BOUNDARY
FILL POINT m F
H A
NO
GRADIENTS WILL COMPLY WITH
4
STOPPING
EUMUNDI - NOOSA ROAD AUSTRALIAN STANDARDS WITH
REGARDS TO HEAVY VEHICLES.
PASSING LANE
A.C.N. 004 610 459
THIS STANDARD DRAWING IS THE PROPERTY OF VIVA ENERGY AUSTRALIA LTD. COPIES
OF THE CURRENT APPROVED VERSION OF VIVA ENERGY STANDARD DRAWINGS ARE
DISTRIBUTED ON THE PROVISION THAT NO MODIFICATION WILL OCCUR UNLESS THE
MODIFICATION IS AUTHORISED, CHECKED AND APPROVED BY AN AUTHORISED VIVA
SHOP ENERGY REPRESENTATIVE. MODIFICATIONS WHICH ARE REQUIRED FOR THIS DRAWING
REAR TANKER UNLOADING ACCESS
TO GAIN APPROVAL FOR A SITE SPECIFIC APPLICATION MUST INCLUDE THE
RE-NUMBERING OF THIS DRAWING TO THE NUMBERING SCHEME OF THE PROJECT.
PURACEPTOR
Meinhardt Australia Pty Ltd
DWG FILE: C:\Users\JBolanos\Desktop\Noosaville, QLD\Drawings\112911 Noosaville, QLD SK Preliminary.dwg - MH PLOT TIME: 21 Jun 2016, 1:28pm
A.C.N. 052 275 635
Level 11, 501 Swanston Street
Melbourne VIC 3000
Australia
T: +61 3 8676 1200
F: +61 3 8676 1201
[email protected]
http://www.meinhardtgroup.com
16
PROPOSED CARPARKING VIVA ENERGY PROJECT NUMBER
12 TBA
PROJECT
AIR &
PROPOSED CARPARKING
PROPOSED RETAIL DEVELOPMENT
VENTS WATER
NOOSAVILLE, QLD
140-142 EUMUNDI ROAD
PROPOSED 7M CLIENT
PYLON SIGN VIVA ENERGY AUSTRALIA LTD
SITE BOUNDARY
TITLE NORTH
MODIFIED EXISTING 19m B-DOUBLE TANKER
CROSSOVER MODIFY CROSSING FOR TURNING PATH
(ENTRY ONLY) SAFE TRUCK ACCESS FRONT TANKER UNLOADING
EUMUNDI - NOOSA ROAD DESIGNED
JB
CONSULTANT'S PROJECT No
DRAWN
JB
APPROVED SCALE @ A1 SCALE @ A3
1:150 1:300
..
PMC PROJECT No DRAWING No REV
112911 SK01B B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.