Delegated Report - Code - Planning RAL22 0026
Stormwater Drainage
20. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property and be generally in accordance with
ALTA’s Roadwork Layout Plan (A6682/22/P03) dated 28 November 2022.
Services
21. Reticulated electricity and telecommunication services must be provided to each lot in
accordance with the standards and requirements of the relevant service provider.
22. Unless otherwise stipulated by telecommunications legislation at the time of construction, the
development must be provided with all necessary conduits, pits and pipes to accommodate
the future connection of optic fibre technology telecommunications.
23. Certification must be submitted to Council from all relevant service providers (Energex, NBN)
which certifies that the development has met the requirements of this Decision Notice and
all applicable legislation at the time of construction.
Easements
24. Unless otherwise agreed in writing by the relevant service provider, any public or third party
infrastructure located on the subject site must be placed within an easement registered
against the title of the property.
25. All easements must be designed in accordance with the planning scheme and granted at no
cost to the Grantee. Where the Grantee is Council or a service authority, the easement
documentation must be in accordance with the Grantee’s standard easement terms. Draft
easement documentation must be submitted to Council for endorsement.
26. All works must be kept clear of any existing or proposed easements on the subject land,
unless agreed otherwise in writing by the Grantee.
Geotechnical Stability - Subdivisional Requirements
27. All subdivisional works must be carried out in accordance with the recommendations
contained in section 4 of Tectonic’s Slope Stability Assessment (22328-001-Rev1) dated 17
November 2022.
Geotechnical Stability - Future Dwelling Requirements
28. All future dwellings on the approved lots must be sited and constructed in accordance with
the recommendations contained in section 4 of Tectonic’s Slope Stability Assessment
(22328-001-Rev1) dated 17 November 2022, unless varied by a site specific investigation
for a particular house lot.
29. All future dwellings on the approved lots must be sited within the building envelopes shown
on the Approved Plans.
Earthworks and Retaining Walls
30. All fill and associated batters must be undertaken in accordance with an Operational Works
approval, and contained entirely within the subject site unless written permission from the
respective landowner(s) is provided to Council.
31. All retaining walls must be designed and constructed in accordance with the planning scheme
and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
safety fence.
Damage to Services and Assets
32. Any damage caused to existing services and assets as a result of the development works
must be repaired at no cost to the asset owner at the following times:
a. where the damage would cause a hazard to pedestrian or vehicle safety,
immediately; or
Page 12 of 14
Document Set ID: 22158749
Version: 8, Version Date: 12/01/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.