RFI response - Land Design Rehab Management Plan Pottery St

Attached to the e-mail RFI Response, land Design Rehab Management Plan - Re: 19660 - 30 Pottery St - Request to restart the clock for decision Making period - OPW26/0033.

of 7
                                                                                                                                                                                                  Area Specific Treatments
                                                                                                                                                    Treatment Area 1 – Rehabilitation Zone (Approx. Area 7,675m2)

                                                                                                                                                      This area contains a high level of ecological resilience and requires minimal work to be rehabilitated. This
                                                                                                                                                      can be achieved by adopting the following procedure:
                                                                                                                                                      •    Weed treatment to occur targeting all non-native species.
                                                                                                                                                      •    Ongoing regular maintenance as per the maintenance requirements on Sheet LD-06.

                                                                                                                                                    Treatment Area 2 – Lomandra Buffer Planting

                                                                                                                                                     A Lomandra buffer is to be achieved by mass planting of Lomandra longifolia. Treatment within this area is to
                                                                                                                                                     proceed as follows:
                                                                                                                                                      •   Weed treatment to occur targeting all non-native species.
                                                                                                                                                      •   Apply a 2m wide, 100mm thick layer of aged, weed free forest mulch, along the eastern boundary as
                                                                                                                                                          per Figure 3.
                                                                                                                                                      •   2 rows of Lomandra longifolia to be installed at 1 per m2
                                                                                                                                                      •   Plants to be installed as per Figures 1 and 2, at the densities specified in Table 4.
                                                                                                                                                      •   Ongoing regular maintenance as per the maintenance requirements on Sheet LD-06.
                                         VEGETATION COVENANT AREA 7,675m2                                                                            Table 4. Area Specific Treatments


                                                                                                                                                                                            VEGETATION COVENANT
                                                                                                                                                                                        PLANTING SCHEDULE (RE 12.11.3)
                                                                                                                                                                                                  GROUNDCOVER
                                                                                                                                                        BOTANICAL NAME                    COMMON NAME            DENSITY                          APPROX. QTY
                                                                                                                                                    Lomandra longifolia               Spinyhead Matt Rush   2 rows at 1m spacing                      200
                                                                                                                                                                                                                           TOTAL                      200
                                                                                                                                                      Table 5. Planting Schedules




                                                                                     NO CLEARING
                                                                                        ZONE




 Figure 3. Treatment Area Mapping


                                LEGEND

        Treatment Area 1 – Rehabilitation Zone (Approx. Area 7,675m2)

IIIII   Treatment Area 2 – Lomandra Buffer Planting

        No Clearing Zone.
                                                                                                                                                     Figure 4. Treatment Area 1 – Rehabilitation Zone


                                                                                        PROJECT     30 POTTERY ST, POMONA                                     ISSUE      DATE       DESCRIPTION

                                                               294 COLES CREEK RD,
                                                                 COORAN QLD 4569
                                                                                        CLIENT      BRIAN NAISMITH DEVELOPMENT CONSULTANT                       A     03/07/26      For Approval

                                                               PHONE: 0417 619 457
                                                                                                                                                                                                                                   SHEET LD-07
                                                            [email protected]
                                                                                        DOC TITLE   LD-RMP POTTERY ST
                                                             WWW.FLORAFIED.COM.AU
                                                                                        DATE        03/07/2026                DRAWN    JF   ISSUE      A

Log in to download the original (RFI response - Land Design Rehab Management Plan Pottery St.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.