Original source · versioned page text
Bushfire Hazard Assessment & Management Plan
Attached to the e-mail REC16/0014 - Planning report & supporting management plans, contour plan 2 of 2.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan - v1 NCES REF: NEX 2016-03 Lot 70 on M37807 – 28 Elkhorn Drive, Tewantin Table 4 - Bushfire Hazard Overlay Code (Reconfiguring a Lot) SPECIFIC OUTCOMES PROBABLE SOLUTIONS PROPOSED SOLUTION General O10 The safety of people and property are S10.1 The proposed lots are not located on land that is subject to Medium or High maintained by Bushfire Hazard on overlay maps OM1.4-OM9.442; OR a) Locating house site areas and other S10.2 The proposed lots are sited on land determined as low bushfire risk by a site S10.2 The development site has been identified to sensitive uses on that part of the land specific bushfire hazard assessment. be captured in a Low hazard sub unit. least affected by the bushfire hazard; AND and S10.3 Additional lots are not created where their only vehicular access route is through a S10.3 Vehicular access to the new lots is via a b) fire mitigation methods are used that are Medium or High Bushfire Hazard area shown on overlay maps OM1.4-OM9.4 new road to be constructed through a Low Hazard adequate for the Potential Bushfire Area identified on OM1.4 - 9.4. Hazard rating of the individual site, having regard to – i. vegetation type; ii. slope; iii. aspect; iv. on-site and off-site fire hazard implications of the development; v. bushfire history; vi. conservation values of the site; and vii. ongoing maintenance. Firebreaks and fire access tracks S11.1 Firebreaks are provided by— Alternative Solution Proposed. The low threat of O11 Firebreaks or fire access tracks provide— a) a cleared road reserve not less than 20m wide located around the perimeter fire on the site post development does not warrant a) adequate access for fire fighting and of the subdivision, between the created lots and surrounding vegetated lands; inclusion of fire break trails along the eastern or other emergency vehicles; and OR western boundaries of the site. b) adequate width to minimise the risk of b) b) fire access tracks (may be in the form of an access easement) between the fire crossover. created lots and surrounding vegetated lands that— i. are a minimum cleared width of 6m; ii. have a formed pavement; iii. have access at each end and in other locations where necessary; iv. have passing areas and turning areas; v. have clearly identified access points for emergency vehicles; and vi. are located on public land or within access easements that are granted in favour of the Sunshine Coast Regional Council and the Queensland Fire and Rescue Service. © 2016 21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.