Original source · versioned page text
Decision Notice - RAL21 0035 [As Published]
Approved Plans
2. Development authorised by this approval must be undertaken generally in accordance with
the Approved Plans listed in the table below. The plans must be amended to incorporate the
amendments listed within the table below and resubmitted to Council prior to the issue of any
Development Permit for Operational Works*
Plan No. Rev. Plan/Document Name Date
21-5581AA Plan of Proposed Reconfiguration Prepared 18.11.2021
by Max Watterson and Associates
Currency Period
3. This development approval lapses if the requirements of the conditions have not been
completed and an application for plan seal is not lodged with Council by 24th July 2027,
unless an application to extend the currency period is approved by Council.
4. All lot numbering on the subdivision plan to be submitted to Council for compliance
assessment must remain as shown on the Approved Plans.
Building Envelope
5. All future dwellings and associated ancillary buildings and structures on proposed Lot 2 must
be wholly located within the approved building envelope as shown on the Approved Plans.
A copy of the approved Plan of Development must be included in the contract of sale for Lot
2, together with a clause which requires future dwellings and associated ancillary buildings
and structures to be constructed in accordance with it.
The following property notation or similar will be added to Council’s rates records for
proposed Lot 2:
A house site has been specified for this property as part of the conditions of subdivision
approval. The approved site for the construction of a future dwelling and associated ancillary
buildings and structures is shown on the attached plan. (refer to Council Approval
RAL21/0035).
6. The applicant must prepare a metes and bounds building envelope plan indicating the
approved building envelope for Lot 2. The areas must be generally in accordance with the
approved plans. The plans must be submitted in both hardcopy and digital format (dwg) on
GDA 94 zone 56 coordinates. The applicant must submit the plans to Council for approval
prior to the endorsement of the Plan of Survey.
ENGINEERING
Site Access and Driveways
7. An access driveway must be provided extending from the formation in Jirrima Crescent to
the common boundary of proposed Lots 1 and 2. The works must be undertaken in
accordance with an Operational Works approval and must include in particular:
a. the works generally as shown on drawings numbered C30-C33 (Revision 2) prepared
by RECOR Consulting dated 15 May 2023
b. any sections of the existing gravel formation that will be affected by flooding up to the
1% AEP event must be sealed
c. all works must be constructed to achieve the flood immunity and trafficability as
described in section 3 of the submitted Stormwater Management Plan – reference
20220089 prepared by Recor Consulting dated May 2023
d. any necessary safety measures or warning signage in the proximity of the watercourse
crossing
e. underground service conduits for all utility services.
Page 2 of 9
Document Set ID: 22524862
Version: 3, Version Date: 31/07/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.