Skip to the record
The gold standard in government transparency.

Council archive · source document

Approved Plans - MCU22-0135 · MCU22/0135

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                NOOSA COUNCIL
                APPROVED PLAN
              MCU22/0135 7 OCT 2022




          Colorbond Custom orb roof
          sheeting fixed to manufacturers
          specification for required wind
          category. (5° pitch).

          Colorbond slotted gutter,                                                                                                                                                                                                                                                                                                                                          Aluminum framed Doors
          fascia to match roofing. Fix to                                                                                                                                                                                                                                                                                                                                    to manufacturers specification.
          manufacturers specification.



                                                                                                                                                                 2°                                                                                                                                                                                             2°

                                                                                                                                                                                                                                                                                                                                                                             Rendered brick veneer
                                                                                                                                                                                                                                                                                                                                                                             walls to engineers details.
              Ceiling Height
       2700




                                                                                                                                                                                                                                                                                                                                                                             Select Timber Cladding fixed to
                               Joinery
                2400




                                                                                                                                                                                                                                                                                                                                                                             manufacturers specification.




                                                                                                                                                                                                                                    Joinery
                                                                                                                                                                                                                             1650
                                                                                                                                                                                                                                                                                                                                                                             Aluminum framed windows
          Approx. Existing                                                                                                                                                                                                                                                                                                                                                   to manufacturers specification.
          Ground Line.
          Approx. Proposed
          Ground Line.
                                                                                                                                                                                                                          SOUTH WEST ELEVATION
                                                                                                                                                                                                                          Scale : 1 : 100




                                                                                              Revision Schedule                                Project Address :                                                                Sheet Name:                                                   Project Status:               Project Number:   * Parapet heights are dependent on the truss upstand.
                                                                                           Number Description    Date Issued by                No. 49 Donnellys Road, Ridgewood                                                 Elevations                                                    WD                            20-060            Builder to confirm truss upstands with truss
                                                                                           1     WD           20/01/20 BJH                                                                                                                                                                                                                    manufacturers prior to building parapet walls to ensure
                                                                                                                                            Client Name :                                                                         Project Issue Date :                                                Q.B.C.C Lisence No.   Sheet Number:     roofing & adequate flashing is hidden behind parapet walls.
    Email: [email protected]
    Website: www.iconbuildingdesign.com.au                                                                                                  Rhys          &   Monique                                                             20/01/2021                                                          126221                10
Document    Set ID: 22061202
     C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Version: 1, Version Date: 04/08/2022

Used in these records

About this file

File size
4.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plans - MCU22-0135.pdf · 4.8 MB (large file)