ELECTRICAL NOTES:
1. PROVIDE 3 PHASE SUPPLY FROM STREET.
APPROVED WITH CONDITIONS
2. PLACE ALL POWER POINTS AND OUTLETS TO
This is an Approved Building Works Document. Refer
SUIT CABINETRY AND/OR FITTINGS. to the Decision Notice for conditions of approval
REMAINING POWER POINTS AND OUTLETS TO
BE MOUNTED 300mm AFFL. PERMIT No. 35484
3. PROVIDE SUPPLY POWER TO A/C UNITS AS
REQUIRED. DATE 09/11/2023
4. PROVIDE SEPARATE CIRCUITS FOR FRIDGES. ISSUED BY COASTAL BUILDING
CERTIFICATIONS PTY LTD
ELECTRICAL PLAN TO BE READ IN
CONJUNCTION WITH JOINERY PLANS FOR
MORE DETAILED POWER POINT PLACEMENT
KEY:
MAIN SWITCHBOARD
SUB BOARD
NETWORK DISTRIBUTOR
DOUBLE GPO
SINGLE GPO
DOUBLE DATA/PHONE OUTLET
SINGLE DATA/PHONE OUTLET
TV OUTLET
INTERCOM
SECURITY SENSOR
300 300 300 300
CCTV CAMERA
PROVIDE POWER
HDMI HDMI CABLE TO HEATED TOWEL RAIL
PROVIDE POWER
CAT CAT CABLE TO HEATED TOWEL RAIL
PIN PIN PAD
STORE PDR GUEST HDMI
M/CBD
SPK CEILING MOUNTED SPEAKER
1100 1500 STUDY
CAT
CEILING MOUNTED HEATER
M/CBD
GPO
MOTORISED BLINDS RECESSED
300 INTO GROUND
SD SMOKE DETECTOR ROBE
HDMI
AUTOMATION CONTROL
T LIFT
TOUCH PANEL ROBE ROBE CAT
CONFIRM LIFT POWER
A/C A/C CONTROL PANEL REQUIREMENTS WITH 1500
MANUFACTURER
TH THERMOSTAT 300 HDMI
SECURITY SWITCH CAT
1500
CEILING MOUNTED WAP
(WIRELESS ACCESS POINT) FAMILY
USB CHARGER
PLANTER
STAIRS SPK SPK
300 300
300
GAMES
SPK SPK
SPA
GYM 600
(ZIP)
700
300
CHANGE SAUNA BAR
HDMI ROOM CONFIRM INFRA RED
SAUNA POWER
REQUIREMENTS WITH
CAT MANUFACTURER
1500
600
COMMS (BF)
WINE
CONFIRM COMMS POWER
REQUIREMENTS WITH SMART
HOME CONSULTANT
1100
CLIENT: Maxine Horne PROJECT: BEACHES
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: BEACHES NOOSA 7/56 David Low Way, SUNRISE BEACH QLD 4567
A: OFFICE 1/20 DUKE STREET, to verify all dimensions on site prior to commencing works. Site
SUNSHINE BEACH, QLD 4567, location in accordance with engineers details. These drawings are to DRAWING TITLE: LOWER POWER PLAN
be read in conjunction with engineers design and details, the
E: [email protected] DATE: 31-08-23 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
P: (07) 54748 107 BSA LICENCE: 1127508
accompanying building specification and schedule of finishes. If in
doubt, please request clarification. DO NOT ASSUME. ISSUE: PRELIMINARY WORKING DRAWINGS
W8.0 -1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
35484 APPROVED PLANS BA.pdfRelated documentApplication case desk ↗
About this file
- File size
- 18.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.