KEY:                                                           NOTES:
            FLOURESENT TUBE LIGHT        INTERNAL WALL LIGHT   1. PROVIDE 3 PHASE SUPPLY FROM STREET.                                                                                                                                                                                                                                                                                               APPROVED WITH CONDITIONS
       L                            S
            LED STRIP LIGHTING           STAIR WALL LIGHT      2. PLACE ALL LIGHT SWITCHES AT 1100mm AFFL.                                                                                                                                                                                                                                                                                     This is an Approved Building Works Document. Refer
       DL                           E
            DIRECTIONAL LED STRIP        EXTERNAL WALL LIGHT
                                                               3. PLACE ALL POWEWR POINTS AND OUTLETS TO SUIT
                                                                                                                                                                                                                                                                                                                                                                                                 to the Decision Notice for conditions of approval
       LV
            LV DOWNIGHT             D    UP/DOWN WALL LIGHT    CABINETRY AND/OR
                                                               FITTINGS. REMAINING POWER POINTS AND OUTLETS TO BE                                                                                                                                                                                                                                                                                   PERMIT No. 35484
            LED DOWNLIGHT           P    POOL/POND LIGHT       MOUNTED 300mm AFFL.
       P
            PENDANT LIGHT                                      4. PROVIDE SUPPLY TO A/C UNITS AS REQUIRED.
                                                                                                                                                                                                                                                                                                                                                                                                    DATE 09/11/2023
                                         EXHAUST FAN
       G
            LV GARDEN LIGHT                                                                                                                                                                                                                                                                                                                                                                     ISSUED BY COASTAL BUILDING
                                         MOTION SENSOR         5. PROVIDE SEPERATE CIRCUIT FOR FRIDGE.
       U                                                                                                                                                                                                                                                                                                                                                                                        CERTIFICATIONS PTY LTD
            RECESSED LED UP LIGHT
                                    SD                         6. ENERGY EFFICIENT LIGHTING TO BE INSTALLED TO A MINIMUM
                                         SMOKE DETECTOR
       W                                                       OF 80% OF TOTAL FIXED LIGHTING POSITIONS. (BASED ON
            POND LIGHT IMMERSED     TD   THERMAL DETECTOR      NUMBER OF LIGHTS INSTALLED INTERNALLY & IN OUTDOOR
       SP                                                      COVERED AREAS).
            DIRECTIONAL SPOTLIGHT   X    SWITCH
                                                               7. SEE JOINERY DETAILS FOR LOCATION & EXTENT
            CEILING FAN             2    2-WAY                    OF LED STRIP LIGHTING.
                                    3    3-WAY
                                                               8. GARDEN LIGHTS TO BE ON MOTION SENSORS.
                                    D    DIMMER
                                                               9. GARDEN LIGHTS TO FUTURE DETAIL.
                                         SWITCHWIRE



IN ACCORDANCE WITH COUNCIL DA REQUIREMENTS

- ALL OUTDOOR LIGHTS MUST HAVE A MAXIMUM OF 2700 K CORRELATED COLOUR TEMPERATURE
(CCT). ALL INDOOR LIGHTS MUST HAVE A MAXIMUM OF 3000 K CCT. ALL LIGHTING (INTERIOR AND
EXTERIOR) MUST AVOID THE USE OF HALOGEN, METAL HALIDE, OR FLUORESCENT LIGHTS.

- AMBER LED (590-610 NM) OR LOW PRESSURE SODIUM LIGHTING MUST BE USED AS A STANDARD.                                                                          PDR
WARM WHITE IS TO BE USED ONLY WHERE COLOUR RENDITION IS REQUIRED. LED LIGHTS MUST NOT                                                                                               G
CONTAIN SHORT WAVELENGTH BLUE LIGHT AND SUPPLIER SHOULD BE ASKED TO PROVIDE SPECTRAL                                                                                                          G
POWER CURVE OF REQUESTED LEDS TO PROVE THE ABSENCE OF SHORT WAVELENGTHS.                                                                                        DL2                                                                                                                                P
                                                                                                                                                       WL

- THE NUMBER AND WATTAGE OF LIGHTS MUST BE MINIMISED.                                                                                                                                                                                                                                                              REF TO COUNCIL NOTES
                                                                                                                                                                                                                                                                                                                   FOR EXTERNAL LIGHTING




                                                                                                                                                                        xx
- ALL LIGHTS MUST BE RECESSED INTO STRUCTURES AND ROOF, AND DIRECTED AWAY FROM THE TURTLE                                                              DL2                              DL2
NESTING HABITAT.
                                                                                                                                                                                                                      DL2                               DL2
                                                                                                                                                                                                                                                                                                                              P
- NO LIGHTING IS PERMITTED ON THE ROOF OF THE BUILDING.                                                                                                                                                                           LIVING
- ALL OUTDOOR LIGHTS, INCLUDING BALCONY LIGHTS, MUST BE TURNED OFF BETWEEN 8:00PM AND                                                                       LIFT
SUNRISE DURING TURTLE NESTING AND HATCHING SEASON (OCTOBER – MAY).                                                                                    CONFIRM LIFT LIGHTING                                           SPK                                       SPK
                                                                                                                                                     WITH LIFT MANUFACTURER
                                                                                                                                                                                        DL2
- EXTERNAL FEATURE LIGHTING TO THE BUILDING MUST BE POSITIONED BELOW 10 METRES IN HEIGHT AND                                                                                                      x




                                                                                                                                                                                                      xx
TURNED OFF BETWEEN 8:00 PM AND SUNRISE DURING TURTLE NESTING AND HATCHING SEASON
(OCTOBER – MAY).
                                                                                                                                                                                                                                                                                                       SPA
                                                                                                                                                                                                                                                                                                       P                      P
                                                                                                                                                                                                                      DL2                               DL2
- NO UPWARD LIGHTS OR VERTICAL ILLUMINATION OF THE BUILDING, VEGETATION OR OTHER STRUCTURES                                                                     VOID
USING LIGHTING THAT SHINES INTO THE SKY TO BE USED.                                                                                                                                                                                                                                                                               POOL
                                                                                                                                                                                                                       ALL FEATURE LIGHTING TBC WITH INTERIOR
                                                                                                                                                                                                                            DESIGNERS & HOME AUTOMATION
- WHERE LIGHTING IS REQUIRED FOR SAFETY PURPOSES (INCLUDING ALL CORRIDORS ABOVE GROUND                                                                                                                                              CONSULTANT

LEVEL, STAIRWELLS, ENTRY POINTS ETC.), THE LIGHTING OF THESE AREAS MUST BE ACTIVATED BY
PROXIMITY SENSORS OR MOTION DETECTORS WITH AN ASSOCIATED DEACTIVATION OF THE LIGHTING                                                                          STAIR LIGHTING TBC WITH INTERIOR
                                                                                                                                                                DESIGNERS & HOME AUTOMATION
AFTER NO MORE THAN 10 MINUTES DURING TURTLE NESTING AND HATCHING SEASON (OCTOBER – MAY).                                                                                 CONSULTANT

FOR LIGHTING IN OTHER AREAS, TIMERS, PROXIMITY OR MOTION ACTIVATED LIGHT SENSORS MUST BE USED                                                                         STAIRS                                                                                                                                                  P
WHEREVER POSSIBLE.
                                                                                                                                                                                                                                  DINING
- NO DECORATIVE OUTDOOR LIGHTING IS TO BE FITTED TO THE BUILDINGS, OPEN SPACE OR RECREATION
                                                                                                                                                                                                            M




                                                                                                                                                                                                      xxx
AREAS (E.G. FAIRY/CHRISTMAS LIGHTS) DURING NESTING AND HATCHING SEASON (OCTOBER – MAY).                                                                                                                                             P     P    P                                                           G

                                                                                                                                                                                                                                  PENDANT LIGHTS
- POOL LIGHTING MUST BE SWITCHED OFF AFTER 8:00PM DURING NESTING AND HATCHING SEASON                                                                                                                                             TO BE CONFIRMED
                                                                                                                                                                                                                               BY INTERIOR DESIGNER
                                                                                                                                                                                                                                                                                                               G
(OCTOBER – MAY).                                                                                                                                                         DL2

- ALL EXTERIOR LIGHTING MUST BE SHIELDED BY A MINIMUM OF 30CM VERTICAL SHIELDING.

                                                                                                                                                                                                                                                                                                                                REF TO COUNCIL NOTES
                                                                                                                                                                                                                                                                                                                                FOR EXTERNAL LIGHTING
                                                                                                                                                                         DL2                                                    KITCHEN                                                                                   L
                                                                                                                                                               PANTRY
                                                                                                                                                                                    x
                                                                                                                                                                                                                                                                                                                                        ALL OUTDOOR
                                                                                                                                                                         DL2                                                                                                                                                             LIGHTING ON
                                                                                                                                                                                                                                                                                                                                        SENSOR WITH
                                                                                                                                                                                                                DL2                     DL2                           DL2                                                         MASTER SWITCH TO KITCHEN
                                                                                                                                                                                                                      ALLOW CLEARANCE FOR CBD DOOR OPENING
                                                                                                                                                                                                                                                                             xx




                                                                                                                                                                                                                                                                                             OUTDOOR
                                                                                                                                                                                                                                                                                           ENTERTAINING



                                                                                                                                                                                                                                                                            WALL LIGHTING
                                                                                                                                                                                                                                                                            TO BE CONFIRMED
                                                                                                                                                                                                                                                                            BY INTERIOR DESIGNER




                                                                                                                                                                                                                                                                                                                                                             CLIENT: Maxine Horne                    PROJECT: BEACHES
                                                                                                                           www.chriscloutdesign.com.au                                                                                                                 GENERAL NOTES:
                                                                                                                                                                                                                                                                       Use written dimensions only. DO NOT scale drawings. Contractors                       SITE ADDRESS: BEACHES NOOSA 7/56 David Low Way, SUNRISE BEACH QLD 4567
                                                                                                                           A: OFFICE 1/20 DUKE STREET,                                                                                                                 to verify all dimensions on site prior to commencing works. Site
                                                                                                                              SUNSHINE BEACH, QLD 4567,                                                                                                                location in accordance with engineers details. These drawings are to                  DRAWING TITLE: UPPER LIGHTING PLAN
                                                                                                                                                                                                                                                                       be read in conjunction with engineers design and details, the
                                                                                                                           E: [email protected]                                                                                                                                                                                                   DATE: 31-08-23 SCALE: 1 : 100   @ A2 DRAWN BY: C.CLOUT
                                                                                                                           P: (07) 54748 107 BSA LICENCE: 1127508
                                                                                                                                                                                                                                                                       accompanying building specification and schedule of finishes. If in
                                                                                                                                                                                                                                                                       doubt, please request clarification. DO NOT ASSUME.                                   ISSUE: PRELIMINARY WORKING DRAWINGS
                                                                                                                                                                                                                                                                                                                                                                                                                               W7.2

Used in these records

About this file

File size
18.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

35484 APPROVED PLANS BA.pdf · 18.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.