Original source · versioned page text
2018-11-12 General Committee Meeting Agenda
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
GENERAL COMMITTEE MEETING AGENDA 12 NOVEMBER 2018
Page 48 of 84
GENERAL COMMITTEE MEETING AGENDA 12 NOVEMBER 2018
2007/2446
MATERIALS ON-SITE DESTINATION
Expected waste | Estimated | On-site Off-site “specify
materials volume “specify proposed | “specify contractor and
(m7) re-use or on-site | contractor and | landfill site or
recycling recycling outlet other disposal
methods site
a TE
material
[Greenwaste {|
[Bricks |
[Concrete |
ye | TT
Plasterboard a Bs ee
Sey | |
Oe ai
EE
De =
Note * If a demolition contractor is undertaking works, then the Waste Management table is to
be completed by the demolition contractor.
The purpose of the Waste Management Plan is to facilitate the segregation of waste for the
effective reuse and recycling of such materials. Additionally Council rewards those who
segregate waste by significantly reducing disposal fees at the landfill some items are free.
Higher gate fees are charged for loads of mixed waste.
Noise
55. Noise emission from mechanical equipment (air conditioners, refrigeration equipment or pool
pumps etc) shall comply with the following requirements:
The equipment shall be installed and located in a manner that prevents excessive noise in
accordance with Council's Local Law No. 12 - Control of Nuisances. Infringement Notices
(on-the-spot fines) may apply for offences.
A person must not use equipment on any day if it makes or causes noise to be made - From
10pm to 7am: More than the lower of either —
e 40 dB(A)
* 3dB(A) above the background noise level
* No audible noise for pool pumps apply during these hours.
From 7am to 7pm: More than the lower of either —
* 50 dB(A)
* 5 dB(A) above the background noise level
From 7pm to 10pm: More than 3 dB(A) above the background noise level.
56. Submission of written certification from a suitably qualified person confirming that the noise
levels from all mechanical equipment comply with the cause above when measured at either
the residential boundary or outside the most exposed part of an affected building, whichever
is the closest to the equipment.
Page 10 of 17
Page 48 of 84See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.