07/2357 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132007.2357

of 74

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

All Residential Uses Code

 

 

Column 1 foresaw Column 3
RT s\re em Ore read Probable Solutions (if code assessable) fore Litay
Effects of use
Electricity supply infrastructure
01 — The development does not adversely impact on existing | $1.7.No solution provided Not applicable.
or future electricity supply infrastructure;
AND
02 = Alluses and works maintain an adequate safe distance
from electricat infrastructure including substations, overhead $2.1 Development for uses adjacent to or within 50m of an
powerlines, power poles and transformers. existing electricity substation incorporates noise attenuation
measures to mitigate noise impacts;
AND

$2.2 Buildings and structures (including swimming pools,

sheds, tennis courts or outbuildings) are not constructed

under overhead electricity transmission lines, or within

electricity easements,

AND

$2.3 A minimum separation distance is maintained from the

electricity transmission line to the closest boundary of

habitable buildings and child activity areas, as follows—

a) 20m for transmission lines up to 132kV;

b) 30m for transmission lines between 133kV and
275kV; and

9] 40m for transmission fines greater than 275kV.

  

Environmentally Sustainable Building Design

 

Hot Water Systems"

03 Hot water systems are installed and operated to support | $3.1 All hot water systems instatled are— A condition may be recommended accordingly.
the efficient use of natural resources and minimise consequent a) solar systems; or

pollution such as greenhouse gas emissions. b) electric heat pump systems; or

c) natural gas or LPG systems; or
d) any combination of a), b) or c).
Water supply and conservation
04 Onsite water storage is designed and operated to $4.1 If in a designated rainwater tank area as identified in A condition may be recommended accordingly.

support the efficient use of water; Map 1 of Schedule 8, residential uses that qualify as class
4A or 1B structures under the Building Code of Australia
have a rainwater tank or tanks in accordance with Schedule
AND 8.
AND

$5.1 Where not in a water service area a rainwater tank of a
O05 On-site water storage is adequate for occupants every minimum of 60,000 litres is provided for each dwelling unit,

 

 

 

 

 

day use and fire fighting purposes. with the exception of Multiple Housing Type 1.

Erosion and sediment contro!

06 Development does not cause erosion or result in No solution provided. A condition may be recommended accordingly.

transport of sediments off-site. Advisory Note |

 

 

 

 

‘ This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia

Residential Code Glen Irwin & Trevor Matthews
Page 1

Used in these records

About this file

File size
6.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2357 - MCU - Multiple Housing Type 2 - Duplex [As Published].pdf · 6.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.