Council archive · source document
07/2357 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132007.2357
All Residential Uses Code Column 1 foresaw Column 3 RT s\re em Ore read Probable Solutions (if code assessable) fore Litay Effects of use Electricity supply infrastructure 01 — The development does not adversely impact on existing | $1.7.No solution provided Not applicable. or future electricity supply infrastructure; AND 02 = Alluses and works maintain an adequate safe distance from electricat infrastructure including substations, overhead $2.1 Development for uses adjacent to or within 50m of an powerlines, power poles and transformers. existing electricity substation incorporates noise attenuation measures to mitigate noise impacts; AND $2.2 Buildings and structures (including swimming pools, sheds, tennis courts or outbuildings) are not constructed under overhead electricity transmission lines, or within electricity easements, AND $2.3 A minimum separation distance is maintained from the electricity transmission line to the closest boundary of habitable buildings and child activity areas, as follows— a) 20m for transmission lines up to 132kV; b) 30m for transmission lines between 133kV and 275kV; and 9] 40m for transmission fines greater than 275kV. Environmentally Sustainable Building Design Hot Water Systems" 03 Hot water systems are installed and operated to support | $3.1 All hot water systems instatled are— A condition may be recommended accordingly. the efficient use of natural resources and minimise consequent a) solar systems; or pollution such as greenhouse gas emissions. b) electric heat pump systems; or c) natural gas or LPG systems; or d) any combination of a), b) or c). Water supply and conservation 04 Onsite water storage is designed and operated to $4.1 If in a designated rainwater tank area as identified in A condition may be recommended accordingly. support the efficient use of water; Map 1 of Schedule 8, residential uses that qualify as class 4A or 1B structures under the Building Code of Australia have a rainwater tank or tanks in accordance with Schedule AND 8. AND $5.1 Where not in a water service area a rainwater tank of a O05 On-site water storage is adequate for occupants every minimum of 60,000 litres is provided for each dwelling unit, day use and fire fighting purposes. with the exception of Multiple Housing Type 1. Erosion and sediment contro! 06 Development does not cause erosion or result in No solution provided. A condition may be recommended accordingly. transport of sediments off-site. Advisory Note | ‘ This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia Residential Code Glen Irwin & Trevor Matthews Page 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2357 - MCU - Multiple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.