Council archive · source document
07/2357 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132007.2357
Column 1
Specific Outcomes
Amenity and Built form
Safety and security
07 For Multiple Housing Types 2, 3 and 4, buildings and
outdoor spaces are designed to protect the personal security
and safety of residents by allowing for natural surveillance
Emergency access
08 For Multiple housing Type 3, 4 & 5, site design and
layout ensures efficient access and egress for emergency
vehicles.
\Separation of incompatible uses
©9 Development is designed to minimise noise carrying
between dwelling units or accommodation units by locating
noise sensitive spaces such as bedrooms away from noise
generating areas of the development, such as carparking areas
or mechanic plant and equipment or recreational facilities.
Mechanical pliant & equipment
010 Mechanical plant and equipment associated with
Residential Uses are designed and located so as not have an
adverse impact on the visual amenity of the site or surrounding
areas.
L
Residential Code - Glen Irwin and Trevor Mathews
passing through private outdoor living areas.
pore wd
Probable Solutions (if code assessable)
Persons undertaking development, including building
work, are required under the Environmental
Protection (Water) Policy 1997 (EPP) to ensure that
sediment and other material including building
waste, sawdust, concrete, cement or paint are not
deposited or released into a roadside gutter,
stormwater drain or waterway, or inte a place where
it could reasonably be expected to move or be
washed into a roadside gutter, stormwater drain or
waterway and are not washed from the site. Council
enforces the EPP and penalties may apply.
$7.1 The building entrance is clearly identifiable and visible
from the street, footpath and driveway;
AND
$7.2 The intemal path network has clear sightlines to the
dwelling entry and street access points;
AND
$7.3 Visitors have direct access to the entrance without |
No solution provided
$9.1 Bedroom windows are at least 3m away from shared
driveways or carparking areas of adjacent dwelling units or
accommodation units.
$10.1 Mechanical plant and equipment, including poo! and
spa pumps, pool heaters, air-conditioning units and
refrigeration units are—
a) where located at ground level, screened by fencing
1.5m in height or dense vegetation of at least 1.5m
in width incorporating grouped trees and shrubs with
maximum separation distance of 1m measured from
the centre of the plant; and
b) for Multiple housing Type 2, 3 & 4 are visually
integrated into the line and plane of the building and
roof design and do not project beyond the height or
width of the building when viewed from the street
and adjoining properties.
per ure
Compliance
Complies - each unit has a separate defined access located
along the side boundaries. The pathways to the access will be
clearly defined by paving, fighting and landscaping.
Not applicabie.
Complies
A condition may be recommended accordingly.
Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2357 - MCU - Multiple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.