4707_FOSTER AND BLACK - Working Drawings ISSUE B · 51901.4863.08
Very large file (15.6 MB): the original may take a few minutes to open or download. The page text below is quick to read.
FOSTER & BLACK
HASTINGS STREET
BAY VILLAGE
CONSTRUCTION DOCUMENTATION
T a b l e Layout
o f NameC o n t e n t s
Page Sh No.
1.0 Cover Page + Schedule
01 1.1 Cover Page N/A
02 1.2 Codes N/A
2.0 Existing Plans
03 2.1 Floor Plan - Exis ng/Demo 1:20
04 2.2 Eleva ons - Exis ng/Demo 1:50
3.0 Proposed Plans
05 3.1 Floor Plan - Proposed 1:20
06 3.2 Dimension Plan 1:20
07 3.3 Eleva ons 1+2 1:50
08 3.4 Eleva ons 3+4 1:50
09 3.5 Sec on 01 1:20
10 3.6 Interior Eleva on A 1:20
11 3.7 Interior Eleva on B 1:20
12 3.8 Interior Eleva on C 1:20
13 3.9 Interior Eleva on D 1:20
14 3.10 Details NTS
15 3.11 Roof Layout 1:20
16 3.12 Reflected Ceiling 1:20
17 3.13 Services Plan 1:20
18 3.14 Perspec ve Views 01-04 NTS
3.15 Perspec ve Views 05-08 NTS
reitsma
3.16 Perspec ve Views 09-12 NTS
3.17 Health & Safety Notes N/A
3.18 General Notes (2023) N/A
SHOP 8 (No. 18) HASTINGS ST. NOOSA HEADS | ISSUE B | DATE: 24/06/2025 | PROJECT NUMBER: 4707
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 16 (of 22)
Page 2
GENERAL - CODE LEGEND FINISHES - CODE LEGEND GENERAL CONSTRUCTION NOTES
A AWNING WINDOW (SOLID) AWNING WINDOW - WITH FEATURE SK1N CLADDING OVER CB-D CABINETRY - DARK COMPACT LAMINATE CABINETRY - DARK (COLOUR TBC) GENERAL NOTES
AC AC UNIT (EXTERNAL) EXISTING AC CONDENSOR UNIT RELOCATED - NEW WALL BRACKETS (TO BE SLIM CB-G CABINETRY - GREEN COMPACT LAMINATE CABINETRY - GREEN SLATE ( TBC) DO NOT SCALE DIMENSIONS. CHECK AND VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT.
PROFILE) EXISTING FLOORING TO REMAIN THESE PLANS ARE TO BE READ IN CONJUCTION WITH ALL CONSULTANT DOCUMENTATION.
FL EXISTING FLOORING TO BE REVIEWED ONSITE AND REMAIN (TBC BY CLIENT)
AC-S AC - SPLIT SYSTEM EXISTING AC SPLIT SYSTEM TO BE REPOSITIONED TO ALLOW FOR NEW WINDOW - WITHIN TENANCY - TBC
ALL WINDOWS / OPENINGS TO BE VERIFIED AGAINST FLOOR PLANS AND ELEVATIONS BY CONTRACTOR.
(REPOSITIONED) UNIT TO BE PAINTED DARK COLOUR MSH-G PERFORATED MESH - GREEN POWDERCOATED PERFORATED MESH SCREENING TO MATCH PC-G DISCREPANCIES ARE TO BE REPORTED TO THE DESIGNER PRIOR TO COMMENCEMENT.
BB BATCH BREW LOCATION PERFORATED MESH -
MSH-T POWDERCOATED PERFORATED MESH SCREENING TO MATCH PC-T ALL NE W WORK TO COMPLY WITH THE NCC, THESE DRAWINGS AND ALL OTHER RELEVANT TECHNICAL LITERATURE FOR THIS WIND
750mm (NOM) HIGH WAITING BENCH (ST-T) WITH SEMI-CONCEALED WALL TERRACOTTA
BEN WAITING BENCH MOUNTED SUPPORT STRUCT. UNDER (CIRCULAR HOLLOW SECTIONS - PC-T FINISH) - CATEGORY.
PAC 2PAC - GREEN GREEN SLATE TO MATCH CABINETRY - TBC BY CLIENTS
FINAL DETAILS/FIXING TBC BY MANF. CONFIRM PLANS AGAINST EXISTING STRUCTURE PRIOR TO SITE WORKS - CONFIRMATION OF ALL EXISTING ELEMENTS (WALLS, COLUMNS
PC-G POWDERCOATED - GREEN TO MATCH GREEN SLATE CABINETRY COLOUR (CB-G)
BIN BIN (LOCATION) ROOFS, CEILING, FOORS, FLOORING, WINDOWS, SERVICES ETC)
PC-T POWDERCOATED - TERRACOTTA TO MATCH FEATURE CLADDING WRITTEN AUTHORISATION TO BE OBTAINED BY BODY CORPORATE PRIOR TO COMMENCEMENT OF ANY ONSITE/OFF SITE BUILDING
CG COFFEE GRINDERS
PT-D PAINTED - DARK COLOUR (TBC) LEVEL 5 FINISH (TBC BY BUILDER) WORKS
CHS CHS COLUMN UNDER BENCH CHS SUPPORT POST (DARK COLOUR TBC) 50 mm DIA NOM - REFER
ENG. DETAILS PT-G PAINTED - GREEN SLATE PAINTED PLASTERBOARD - GREEN SLATE (TBC) ENGINEERING NOTES
TERRACOTTA (SK1N FINISHED) TILED CLADDING OVER BATTENING SYSTEM - BRICKWORKS - SK1N POTENZA TERRACOTTA TILING TBC SUBJECT ENGINEERING REFER TO ENGINEERS DETAILS FOR:
CL CLADDING - TERRACOTTA SK1N SK1N TERRACOTTA TILING TIEDOWN, BRACING, FRAMING SCHEDULE, ROOF FRAMING AND TRUSS DETAILS, WIND CATEGORY,
INSTALLATION TO MANF. DETAILS ADVICE
CM COFFEE MACHINE ST-T STONE - TERRAZZO NATURAL STONE TERRAZZO ROSSO (TBC) PLUMBING AND DRAINAGE
CUP'B STORAGE CUPBOARD WITH ADJUSTABLE SHELVES - REFER CABINET MAKER TDK DECKING (TO REMAIN) ### DARK STAINED TIMBER DECKING - REF. INT. SELECTIONS TO COMPLY WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY
SEWER LOCATION AND CONNECTION POINT TBC ON SITE BY BUILDER PRIOR TO CONSTRUCTION
EDB ELECTRICAL DISTRIBUTION EXISTING LOCATION TO REMAIN - HOUSING BOX TO BE PAINTED TO MATCH
BOARD CLADDING COLOUR FLOOR PLAN
FC FEATURE CEILING FRAMING PAC FINISH EXISTING AC SYSTEM TO BE REUSED (RELOCATE EXT. AC CONDENSER) REFER TO BUILDERS/ AC SPECIALIST FOR FINAL DETAILS
FW-E FLOOR WASTE - EXISTING APPROXIMATE LOCATION TO REMAIN LIGHTING - CODE LEGEND ELEVATION / SECTION GENERAL NOTES
ALL R.L'S NOTED ARE NOMINAL & SUBJECT EXISTING R.L'S - TBC ONSITE BY BUILDER
HOT WATER SYSTEM -
HWS LB-C LIGHT BOX (CEILING) CUSTOM CEILING LIGHT BOX - DETAILS BY SPECIALIST PROPOSED RENOVATION / MODIFICATIONS TO STRICTLY NOT EXCEED THE HEIGHT OF EXISTING STRUCTURE
EXISTING
- ALL CLADDING SYSTEMS NOTED TO BE FIXED IN ACCORDANCE WITH RELEVANT MANUFACTURES'S SPECIFICATIONS.
ICE MACHINE - ALLOW FOR OPEN CABINETRY SURROUNDING FOR AIR FLOW LB-W LIGHT BOX (WALL) CUSTOM WALL LIGHT BOX FOR PRODUCT BACK LIGHTING - DETAILS BY SPECIALIST - STRUCTURAL ELEMENTS TO BE DETERMINED BY STRUCTURAL ENGINEER AND BUILDER
ICE ICE MACHINE (LOCATION)
(BEHIND) ML MENU LIGHT (ADJUSTABLE) LED ADJUSTABLE LIGHT - FOR MENU BOARD - ALUMINIUM FRAMED WINDOWS/OPENINGS AND DOORS COLOUR TBC BY CLIENT - REFER 3D MODEL
KC KNOCK CHUTE KNOCK CHUTE (BIN UNDER) CUT INTO BENCHTOP - WINDOW SIZES/HEIGHTS SHOWN NOMINAL ONLY ARE TO BE CONFIRMED BY A SITE MEASURE
3D NEON SIGNAGE (ROOF MOUNTED) - '3D COFFEE CUP' LOGO/BRANDING - WITH - DETAILS TO MITIGATE CONDENSATION AND COMPLY WITH ALL RELEVANT CODES - REF. BUILDERS DETAIL
MENU BOARD - WALL MOUNTED ALUMINIMUM NL-1 NEON LIGHT 01 - 3D CUP PC-T MESH SURROUND - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAILS * COLOURS SHOWN ARE INDICATIVE -TO BE CONFIRMED BY CLIENT AND AGAINST DESIGN SPECIFICATIONS PRIOR TO ORDERING
MB MENU BOARD STRIPS WITH MAGNETIC (TBC) INTERCHANGABLE SHEETS
LETTERS - SEE DETAILS (ALL MATTE WHITE) NEON SIGNAGE (SIDE WALL MOUNTED) - FEATURE VERTAL 'foster & black' - IN (PC-T) ROOF NOTES
600mm MILK JUG RINSER (UNDER MOUNT) - CABINETRY BELOW TO BE CUT/ALLOW NL-2A NEON LIGHT 02 - VERT. BOX/HOUSING WITH MESH (PC-T) OVER - WALL MOUNTED FIXING POINT TO SIDED - TILED ROOF TO BE 15.5° (NOM). TERRACOTTA STYLE TILES (SELECTION TBC BY CLIENT) TO SUIT ROOF SLOPE, LOCATION + CAPACITY
MJR MILK JUG RINSER OF HOUSING - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL REQUIREMENTS
FOR PLUMBING - ALL STORMWATER LAYOUTS ARE TO BE DETAILED BY BUILDER+PLUMBING SUPPLIER TO ENSURE ALL WORK TO COMPLY WITH
OHC OVER HEAD CABINETRY NEON SIGNAGE (BACK TO WALL MOUNTED) - FEATURE VERTAL 'foster & black' - IN AS3500.3.2:2003
NL-2B NEON LIGHT 02 - VERT. (PC-T) BOX/HOUSING WITH MESH (PC-T) OVER - BACK TO WALL MOUNTED FIXING - - FLASHING SYSTEMS TO BE DESIGNED + INSTALLED IN CONSULTATION WITH MANUF. DETAILS
OVER HEAD CABINETRY - OVERHEAD CABINETRY - TO CONCEAL SPLIT AC SYSTEM - MESH FACE AND BASE REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL
OHC-M MESH PANELS FOR AIR FLOW
NEON SIGNAGE (WALL MOUNTED) - 'COFFEE CUP' LOGO/BRANDING - IN BOX/
PD PLUMBING DUCT/VOID NL-3 NEON LIGHT 03 - SQUARE HOUSING (POWDERCOATED PC-T) WITH PC-T MESH OVER
PMF PAN METAL FLASHING PAN METAL FLASHED ROOF - TERRACOTTA COLOUR (TO BUILDERS DETAILS) - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL
POS POINT OF SALE POINT OF SALE - POS SYSTEM/COMPUTER ON STAND - FIXED TO COUNTER
PRIVACY SCREENING TO WASH UP ZONE - MESH SHEETING WITH PERIMETER FRAME
PS PRIVACY SCREEN (PC-G FINISH) - FIXED TO TOP OF STONE BENCH (SEMI
CONCEALED FIXINGS)
REF REFRIGERATOR - (SUPPLIED BY OWNER)
UNDERBENCH
TERRACOTTA (SK1N FINISHED TBC) TILED ROOF - INSTALLATION TO MANF. DETAILS -
RF TERRACOTTA TILED ROOF ENGINEERING ADVICE REQUIRED FOR LOW PITCH
RO REVERSE OSMOSIS SYSTEM WALL MOUNTED REVERSE OSMOSIS WATER FILTER SYSTEM - SUPPLIED BY OWNER
SA SMOKE ALARM PROPOSED SMOKE ALARM LOCATION - EXACT LOCATION TBC ON SITE BY SPECIALIST -
TO COMPLY WITH NCC 9.5
SH-D1 SHELVING - DISPLAY (MAIN) FEATURE DISPLAY SHELVING (CB-G FINISH) - WITH LB BEHIND
SH-D2 SHELVING - DISPLAY (POS) VERT. DISPLAY SHELVES FROM NAT. STONE (ST-T) @ POINT OF SALE (WITH LB BEHIND)
SH-O SHELVING - OVERHEAD OPEN OVERHEAD SHELVING
SK-1 SINK (DOUBLE) RECESSED SINK (DARK - SELECTION BY CLIENT)
SK-2 SINK (SINGLE) RECESSED SINK (DARK - SELECTION BY CLIENT)
TIL TIL (POS) CASH DRAW / RECEIPT PRINT (DETAILS BY OWNER)
TOW TOP OF WALL TBC BY BUILDER ONSITE
TP1 TAP DECK MOUNTED - MATTE BLACK TAP+MIXER (TO MATCH TOUCHLESS BOOMERANG)
TP2 TAP - SENSOR SENSOR TAP - TOUCHLESS BOOMERANG (DECK MOUNTED) - MATTE BLACK
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Codes 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder N/A B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 2 /22
Page 3
EXTENT OF EXISTING STRUCTURES TO BE
EXISTING FABRIC ROOF AND STRUCTURE TO BE REMOVED
DEMOLISHED/ REMOVAL TO BE 03
CONFIRMED ON SITE BY BUILDER / CLIENT A B
5,305
02
EXISTING WINDOWS TO BE REMOVED
EXISTING POST TO BE REMOVED
(SUBJECT TO ENGINEERS REVIEW)
1 1
EXISTING FITOUT TO BE REMOVED
A
0
35
x1
00
10
EXISTING RAMP
2,580
04
TO BE REMOVED
EXISTING TENANCY
A
11.72 m2
5
32
x1
00
10
PORTION OF WALL TO BE
REMOVE TO ALLOW FOR
PROPOSED CABINETRY
2 2
EXISTING SERVICE POINTS TO REMAIN
EXISTING SERVICES
CUPBOARD TO REMAIN
01
A B
2.1Floor Plan - Exis ng/Demo
1:20
Revision Notes. Project Client Drawing
0 1 2
Date
5 10
Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Floor Plan - Exis ng/ 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and
verified on site by builder/client prior to commencement of works.
cut and fill ba ers are indica ve only and must be
established and verified by builder/client in rela on to
Demo Scale Revision
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 3 /22
Page 4
EXTENT OF EXISTING STRUCTURES TO BE
DEMOLISHED/ REMOVAL TO BE CONFIRMED ON
SITE BY BUILDER / CLIENT A B
5,305
EXISTING FABRIC ROOF AND EXISTING FABRIC ROOF AND
STRUCTURE TO BE REMOVED STRUCTURE TO BE REMOVED
EXISTING FITOUT TO BE EXISTING WINDOWS
REMOVED (INC TO BE REMOVED
EXTERNAL BENCHTOP)
EXISTING FITOUT TO BE REMOVED
(INC EXTERNAL BENCHTOP)
EXISTING SERVICE
POINTS TO REMAIN
01 Exis ng Eleva on 01 (West)
1:50 02 Exis ng Eleva on 02 (North)
1:50
A B
5,305 2,580
B A 2 1
5,305
EXISTING AC CONDENSOR
TO BE RELOCATED
EXISTING FABRIC ROOF AND
STRUCTURE TO BE REMOVED
EXISTING FABRIC ROOF AND
STRUCTURE TO BE REMOVED
EXISTING WINDOWS
TO BE REMOVED
EXISTING FITOUT TO BE REMOVED
EXISTING FITOUT TO BE REMOVED (INC EXTERNAL BENCHTOP)
(INC EXTERNAL BENCHTOP)
EXISTING RAMP TO BE REMOVED
03 Exis ng Eleva on 03 (East)
1:50 04 Exis ng Eleva on 04 (South)
1:50
2.2Eleva ons - Exis ng/Demo
1:50
Revision Notes. Project Client Drawing Date
1:50
Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Eleva ons - Exis ng/ 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and
verified on site by builder/client prior to commencement of works.
cut and fill ba ers are indica ve only and must be
established and verified by builder/client in rela on to
Demo Scale Revision
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:50 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 4 /22
Page 5
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
03
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
A 1 B
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION 5,305
02
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES SLIM PROFILE ALUMINIUM AWNING WINDOW WITH TINTED+FLUTED GLASS -
POWDERCOATED PERIMETER FRAMING DUAL COLOUR FRAMING - SILL FRAME TO BE CUSTOM
AROUND OPENINGS (PC-T COLOUR) TO TERRACOTTA COLOUR - WINDOW / GLASS FRAME
CAP ENDS OF SK1N TILE CLADDING SURROUND DARK COLOUR - DETAILS BY OTHERS
1280x2710 A NL-2B
1 1
PROPOSED REPOSITIONING OF
WINDOW TO ALIGN WITH BB PROPOSED FRAMING TO BOX OUT
EXISTING BRICK WALL BELOW EXISTING STEPPED CORNER -
CG SUBJECT TO APPROVAL
PS
KC REF - (SUPPLIED BY OWNER) BEN
AWNING WINDOW WITH TINTED
+FLUTED GLASS - DUAL COLOUR - D
FRAMING - SILL FRAME TO BE CUSTOM E
TERRACOTTA COLOUR - WINDOW / CM PLI NER
A
P
SU OW
0
GLASS FRAME SURROUND DARK BIN
55 R OPEN CAVITY ZONE FOR AIR FLOW/
COLOUR - DETAILS BY OTHERS BY DE
x2
UNDER CIRCULATION TO REFRIDGERATOR MOTOR -
UN
80
E FINAL SPACE TBC AGAINST MANUF. DETAILS
12
IC B
FW-E A C
D
1030x1750 A
M
TP1
JR
2,580
04
SK-1
PROPOSED KIOSK
11.96 m2
-3
FW-E
NL
D
OI
/V
S
PO
CT
DU
G
BIN
EXISTING FLOORING TO REMAIN WITHIN TENANCY - TBC
L
TP2
TI
M
SK-2
LU
-P
MB
PD
SH-D2
A
-2
NL
CL
SA SH-D1
CUP'B CUP'B UNDER CUP'B CUP'B
EXISTING WALL TO BE REMOVED TO
RO ALLOW FOR NEW CUP'B IN PACKOUT
- TBC ON SITE BY BUILDERS
2 2
EXISTING SERVICE DOOR TO REMAIN -
RE-PAINTED TO DARK COLOUR (TBC BY WATER EDB
CLIENT), REPLACE HANDLE AND LOCK
(BLACK SELECTION BY CLIENT + FW-E
EXISTING SERVICES APPROXIMATE LOCATION OF EXISTING
TUB / TAP TO REMAIN SERVICES - HOUSING TO BE COLOUR MATCHED
TO PROPOSED SK1N CLADDING COLOUR
EXISTING HWS
LOCATION TO REMAIN EXISTING FLOOR WASTE
WITHIN SERVICES HOUSING
EXISTING MAIN DOOR TO REMAIN - RE-PAINTED -
DARK COLOUR EXTERNALLY AND GREEN
INTERNALLY (TBC BY CLIENT), REPLACE HANDLE
AND LOCK (BLACK SELECTION BY CLIENT
EXISTING DECKING TO REMAIN 1
01
A B
3.1Floor Plan - Proposed
1:20
Revision Notes. Project Client
0 1 2
Drawing
5
Date
10
Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Floor Plan - Proposed 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 5 /22
Page 6
5,485 FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
A 2,054 3,431 B FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
5,305
2,054 2,991 90 260 90ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES
5 176 2,710 545
16
90
1 1
90
260
440
350
670
90
5
90
2,
0
55
2,
70
0
2,434 550
2,054
1,964
FW-E
9
2,580
2,580
10
2,580
1,
1,750
1,750
1,430
2,050
439
FW-E
0
19 35
1
31
35 580 1,790 540
180
256 180
9
65
300
346
390
25
2 2
4
90
90
WATER EDB
+ FW-E
LIGHT FILL REPRESENTS EXISTING WALLS
DARK FILL REPRESENTS PROPOSED WALLS
180 90 575 90 4,060 90 310 90
180 5,305
5,485
A B
3.2Dimension Plan
1:20
Revision Notes. Project Client
0 1 2
Drawing
5
Date
10
Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Dimension Plan 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 6 /22
Page 7
A B
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
5,305
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR NL-1
SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY
WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS
APPROX. TOP OF EXISTING 3.400
[email protected]° ROOF PITCH
PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
H
OF PITC SK1N
NO VISIBLE GUTTERING (AS PER EXISTING STRUTURE - 5.5° RO EXISTING AC CONDENSOR UNIT RELOCATED -
INSTALLATION TO COMPLY WITH MANUFACTURES SPEC. - RF @ 1 AC NEW WALL BRACKETS (TO BE SLIM PROFILE)
970
REFER SECTION & DETAILS (SUBJECT TO APPROVAL) RL 2.602 (NOM)
PMF
SLIM PROFILE ALUMINIUM POWDERCOATED
PERIMETER FRAMING AROUND OPENINGS (PC-T SK1N
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING CEILING HEIGHT 2.350
PROPOSED FRAMING TO BOX OUT EXISTING
STEPPED CORNER - SUBJECT TO APPROVAL
3,320
WALL MOUNTED REVERSE OSMOSIS WATER
NL-2A
FILTER SYSTEM - SUPPLIED BY OWNER
(WITHIN SERVICE CUPBOARD) CL
EXISTING SERVICE DOOR TO REMAIN - RE-PAINTED
2,040 NOM
2,350
(EXISTING)
TO DARK COLOUR (TBC BY CLIENT), REPLACE EDB
HANDLE AND LOCK (BLACK SELECTION BY CLIENT
EXISTING MAIN DOOR TO REMAIN - RE-PAINTED - DARK BEN
COLOUR EXTERNALLY AND GREEN INTERNALLY (TBC BY CLIENT),
REPLACE HANDLE AND LOCK (BLACK SELECTION BY CLIENT
ALUMINIUM PERIMETER KICK (PC-T FINISH) - TO WATER
ALLOW FOR CLADDING FINISH TO STOP ABOVE FGL
(NOM)
FLOOR LEVEL 0.000 (EXISTING)
50
TDK
01 Eleva on 01 (West)
1:50
A B
NL-1
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR
SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY
WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS
APPROX. TOP OF EXISTING 3.400
H
PITC SK1N RF @ PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
° ROOF 15.5°
ROOF
5.5
RF @1 PITCH
970
RL 2.602 (NOM)
NO VISIBLE GUTTERING (AS PER EXISTING STRUTURE -
INSTALLATION TO COMPLY WITH MANUFACTURES SPEC. -
REFER SECTION & DETAILS (SUBJECT TO APPROVAL) SK1N
CEILING HEIGHT 2.350
SLIM PROFILE ALUMINIUM POWDERCOATED
PERIMETER FRAMING AROUND OPENINGS (PC-T
3,320
1,280
1,400
NL-2A
NL-2B
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING
AWNING WINDOW WITH TINTED+FLUTED GLASS - DUAL
2,350
COLOUR FRAMING - SILL FRAME TO BE CUSTOM POS
TERRACOTTA COLOUR - WINDOW / GLASS FRAME A A
SURROUND DARK COLOUR - DETAILS BY OTHERS
NL-3
PROPOSED FRAMING TO BOX OUT EXISTING
300
STEPPED CORNER - SUBJECT TO APPROVAL CL CL
940
880
ALUMINIUM PERIMETER KICK (PC-T FINISH) - TO
500
ALLOW FOR CLADDING FINISH TO STOP ABOVE FGL
FLOOR LEVEL 0.000 (EXISTING)
02 Eleva on 02 (North)
1:50
0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Eleva ons 1+2 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:50 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 7 /22
Page 8
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
B A
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
5,305
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES NL-1
APPROX. TOP OF EXISTING 3.400
[email protected]° ROOF PITCH
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
SK1N RF @ 1
SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY 5.5° RO
WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS OF PIT
CH
970
RL 2.602 (NOM)
NO VISIBLE GUTTERING (AS PER EXISTING STRUTURE -
INSTALLATION TO COMPLY WITH MANUFACTURES SPEC. -
REFER SECTION & DETAILS (SUBJECT TO APPROVAL) SK1N SK1N
CEILING HEIGHT 2.350
SLIM PROFILE ALUMINIUM POWDERCOATED
3,320
PERIMETER FRAMING AROUND OPENINGS (PC-T
NL-2A
NL-2B
1,400
1,280
1,400
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING
AWNING WINDOW WITH TINTED+FLUTED GLASS - DUAL
2,350
COLOUR FRAMING - SILL FRAME TO BE CUSTOM A A
TERRACOTTA COLOUR - WINDOW / GLASS FRAME POS
SURROUND DARK COLOUR - DETAILS BY OTHERS NL-3
300
PROPOSED FRAMING TO BOX OUT EXISTING CL CL
STEPPED CORNER - SUBJECT TO APPROVAL
940
880
880
500
FLOOR LEVEL 0.000 (EXISTING)
ALUMINIUM PERIMETER KICK (PC-T FINISH) - TO
ALLOW FOR CLADDING FINISH TO STOP ABOVE FGL
03 Eleva on 03 (East)
1:50
2 1
2,580
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR NL-1
SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY
WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS
APPROX. TOP OF EXISTING 3.400
PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
EXISTING AC CONDENSOR UNIT RELOCATED - AC
NEW WALL BRACKETS (TO BE SLIM PROFILE) SK1N RF @ NO VISIBLE GUTTERING (AS PER
15.5° EXISTING STRUTURE - INSTALLATION
ROOF
970
RL 2.602 (NOM) PITCH TO COMPLY WITH MANUFACTURES
SPEC. - REFER SECTION & DETAILS
(SUBJECT TO APPROVAL)
CL
CEILING HEIGHT 2.350
SLIM PROFILE ALUMINIUM POWDERCOATED
PERIMETER FRAMING AROUND OPENINGS (PC-T
3,320
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING
NL-2B
1,400
1,030
AWNING WINDOW WITH TINTED+FLUTED GLASS - DUAL
2,350
COLOUR FRAMING - SILL FRAME TO BE CUSTOM A
TERRACOTTA COLOUR - WINDOW / GLASS FRAME
SURROUND DARK COLOUR - DETAILS BY OTHERS
BEN PROPOSED FRAMING TO BOX
20
PROPOSED FRAMING TO BOX OUT EXISTING
STEPPED CORNER - SUBJECT TO APPROVAL OUT EXISTING STEPPED CORNER
940 - SUBJECT TO APPROVAL
880
700
FLOOR LEVEL 0.000 (EXISTING)
(NOM)
200
ALUMINIUM PERIMETER KICK (PC-T FINISH) - TO
ALLOW FOR CLADDING FINISH TO STOP ABOVE FGL
Revision Notes.
04 Eleva on 04 (South)
1:50
Project Client
0 1 2
Drawing
5
Date
10
Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Eleva ons 3+4 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:50 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 8 /22
Page 9
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING 1 2
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS, NOMINAL ROOF TILE / CLADDING 2,580
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS CONNECTION DETAIL
PRIOR TO CABINETRY CONSTRUCTION TILTING BATTEN (BY BUILDER) AS PER MANF. SPEC
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR BRICKWORKS - SK1N POTENZA TERRACOTTA
PLUMBING AND POWER SERVICES TILING TBC SUBJECT ENGINEERING ADVICE
ROOF BATTEN
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS
ROOF CONSTRUCTION BY ENG. TO TOP OR SIDES OF TILED ROOF (TYPICAL) -
INSTALLATION TO COMPLY WITH MANUFACTURES
WATERPROOFING MEMBRANE SPEC. - REFER SECTION & DETAILS
APPROX. TOP OF EXISTING3.400
SK1N
CL PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
SK1N TOP HAT FIXING
INSULATION
PITCH EXISTING AC CONDENSOR UNIT
WATERPROOFING MEMBRANE
5.5° ROOF RELOCATED - NEW WALL
820
R F@1 BRACKETS (TO BE SLIM PROFILE)
NO VISIBLE GUTTERING (AS PER EXISTING NEW ROOF CONSTRUCTION
STRUTURE - INSTALLATION TO COMPLY WITH TO ENGINEERS DETAILS
PMF
MANUFACTURES SPEC. - REFER SECTION &
DETAILS (SUBJECT TO APPROVAL)
50 100
150
PROPOSED STRUCTURAL PERIMETER BEAM TO LB-C
PROVIDE UPSTAND TO NEW TRUSSED ROOF - PAC
NEW STRUCTURE TO ACHIEVE INCREASE FC CEILING HEIGHT 2.350
CEILING HEIGHTS - REFER ENGINEERS DETAILS MSH-G
OHC-M EXISTING AC SPLIT SYSTEM TO BE REPOSITIONED
AC-S 200 TO ALLOW FOR NEW WINDOW - UNIT TO BE
SH-D1 PAINTED DARK COLOUR
PC-T PT-G CL
A
SH-D1
3,320
AWNING WINDOW WITH TINTED+FLUTED
GLASS - DUAL COLOUR FRAMING - SILL FRAME
LB-W
TO BE CUSTOM TERRACOTTA COLOUR -
WINDOW / GLASS FRAME SURROUND DARK
COLOUR - DETAILS BY OTHERS
SH-D1
SLIM PROFILE ALUMINIUM POWDERCOATED
2,350
EDB
2,350
PERIMETER FRAMING AROUND OPENINGS (PC-T
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING
MSH-T
PS TP1 TP2 SH-D1 APPROXIMATE LOCATION OF EXISTING SERVICES
A ST-T - HOUSING TO BE COLOUR MATCHED TO
PROPOSED SK1N CLADDING COLOUR
PT-G CB-G CB-G
REF - (SUPPLIED
BY OWNER) CUP'B CUP'B
OPEN CAVITY ZONE FOR AIR FLOW/
CIRCULATION TO REFRIDGERATOR MOTOR -
FINAL SPACE TBC AGAINST MANUF. DETAILS CL ALUMINIUM PERIMETER KICK (PC-T
FINISH) - TO ALLOW FOR CLADDING
FINISH TO STOP ABOVE FGL
EXISTING FLOORING TO REMAIN
ALUMINIUM PERIMETER KICK (PC-T WITHIN TENANCY - TBC
FINISH) - TO ALLOW FOR CLADDING FLOOR LEVEL 0.000 (EXISTING)
FINISH TO STOP ABOVE FGL EXISTING DECKING TO REMAIN
3.5Sec on 011:20
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Sec on 01 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 9 /22
Page 10
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES
50
LB-C
PAC
FC
50
50
50
50
50
130
CB-G SH-O
380
380
ML
A
1,400
1,270
1,020
1,020
MB
2,400
2,400
CM
2,350
2,350
ST-T POS MJR KC
20
20
20
PT-G
200
TIL
EQ.
ADJUST.
ICE
EQ.
EQ.
950
880
930
930
ADJUST.
CHS
BIN
ADJUST.
EQ.
EQ.
CB-G
ADJUST.
FL
(KICK)
50
584 16 435 16 478 16 599
(NOM)
2,144
(NOM)
A Internal Eleva on A
1:20
0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Interior Eleva on A 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 10 /22
Page 11
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES
LB-C
SLIM PROFILE ALUMINIUM
PAC FC POWDERCOATED PERIMETER FRAMING
50
50
50
CB-G SH-O SH-O SH-O AROUND OPENINGS (PC-T COLOUR) TO
OHC-M
CAP ENDS OF SK1N TILE CLADDING
430
430
AC-S
380
380
A
AWNING WINDOW WITH TINTED+FLUTED GLASS
- DUAL COLOUR FRAMING - SILL FRAME TO BE
PT-G CUSTOM TERRACOTTA COLOUR - WINDOW /
GLASS FRAME SURROUND DARK COLOUR -
PC-T
DETAILS BY OTHERS
(WINDOW)
OVERHEAD CABINETRY - TO CONCEAL
1,020
1,020
1,020
1,020
SPLIT AC SYSTEM - MESH FACE AND
BASE PANELS FOR AIR FLOW
BB
CG
200
2,400
2,400
PS
CM
2,350
TP1
ST-T
KC
20
20
20
20
SK-1
230
40
ST-T
CHS
BEN
20
ADJUST.
950
REF - (SUPPLIED BY OWNER)
ICE
840
930
930
BIN CUP'B
700
FL
50
OPEN CAVITY ZONE FOR AIR FLOW/
CIRCULATION TO REFRIDGERATOR MOTOR -
FINAL SPACE TBC AGAINST MANUF. DETAILS
B Internal Eleva on B
1:20
0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Interior Eleva on B 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 11 /22
Page 12
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES
2,400
SLIM PROFILE ALUMINIUM 350 1,750 300
POWDERCOATED PERIMETER FRAMING
AROUND OPENINGS (PC-T COLOUR) TO
CAP ENDS OF SK1N TILE CLADDING
LB-C
PAC
FC
50
50
50
50
AC-S
380
A
SH-O
OHC-M
ADJUST.
AWNING WINDOW WITH TINTED+FLUTED GLASS - A
DUAL COLOUR FRAMING - SILL FRAME TO BE CUSTOM PT-G
TERRACOTTA COLOUR - WINDOW / GLASS FRAME
SURROUND DARK COLOUR - DETAILS BY OTHERS
1,400
ADJUST.
1,020
OVERHEAD CABINETRY - TO CONCEAL
SPLIT AC SYSTEM - MESH FACE AND
BASE PANELS FOR AIR FLOW
ADJUST.
2,400
2,400
2,350
2,350
ST-T PS MSH-T TP1 TP2
ADJUST.
20
20
CB-G SK-1 SK-2
PT-G
CONCEALED SUPPORT STRUCTURE UNDER
BENCH - FINAL DETAILS/FIXING TBC BY MANF.
REF - ADJUST.
(SUPPLIE
880
880
D BY
OWNER)
OPEN CAVITY ZONE FOR AIR FLOW/
CIRCULATION TO REFRIDGERATOR MOTOR -
FINAL SPACE TBC AGAINST MANUF. DETAILS
CUP'B
FL
50
50
CL CL
900 330 555 315 300
900 1,200 300
2,400
C Internal Eleva on C
1:20
0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Interior Eleva on C 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 12 /22
Page 13
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES
4,460
SLIM PROFILE ALUMINIUM POWDERCOATED 270 130 150 540 1,790 580 1,000
PERIMETER FRAMING AROUND OPENINGS (PC-T
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING
400 150 540 50 530 50 530 50 530 50 580 1,000
50
LB-C
FC PAC
50
50
310 50
50
SH-O
288 50
CB-G
OHC-M
CB-G
OHC
PT-G
288 50
ADJUST. ADJUST. ADJUST. SA
PC-T
A
SH-D1
1,400
ADJUST. ADJUST. +LB-W ADJUST.
288 50
OVERHEAD CABINETRY - TO CONCEAL
SPLIT AC SYSTEM - MESH FACE AND SH-D2
BASE PANELS FOR AIR FLOW MB
+LB-W
ADJUST. ADJUST. ADJUST.
200
288 50
2,400
2,400
(NOM - EXISTING)
2,350
2,350
PS TP2 CUP'B CUP'B
ST-T
2,040
20
POS
50
SK-2
230
CB-G TIL
BEN
20
ADJUST. ADJUST. ADJUST. ADJUST. ADJUST.
900
900
ADJUST.
PT-G
700
CUP'B CUP'B CB-G
FL
50
50
EXISTING MAIN DOOR TO REMAIN - RE-PAINTED -
DARK COLOUR EXTERNALLY AND GREEN
INTERNALLY (TBC BY CLIENT), REPLACE HANDLE
CONCEALED SUPPORT STRUCTURE AND LOCK (BLACK SELECTION BY CLIENT
UNDER BENCH - FINAL DETAILS/
FIXING TBC BY MANF.
D Internal Eleva on D
1:20
0 1 2 5 10
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Interior Eleva on D 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 13 /22
Page 14
590
580
11 500 11
40
500mm DIA ALUMINIUM TOP WITH 149
ROUNDED EDGES (P.COAT MATTE
40
GREEN COLOUR)
590mm DIA ALUMINIUM CAP WITH
200
ROUNDED EDGES (P.COAT MATTE
GREEN COLOUR)
INSET MESH SURROUND TO LIGHTING LOGO 1:20
(P.COAT DARK COLOUR) - INTERNAL STRUCTURAL
350
700
ELEMENT TBC BY MANUFACTURER
1,240
620
CUSTOM NEON LIGHTING WITHIN MESH
CUP - NEON TO ROTATE/PIVOT TBC BY
SPECIALIST / MANUFACTURERS
80
108 40 108
400mm DIA ALUMINIUM BASE WITH
190
ROUNDED EDGES (P.COAT MATTE
GREEN COLOUR)
1:20
30mm DIA (NOM) STAINLESS STELL 400
FIXING POST - SEMI CONCEALED (NOM)
FIXING TO ROOF (REFER TO ROOF
LAYOUT PLAN FOR POSITIONING)
01aDetail 01 - Neon Ligh ng Detail NL-1
N.T.S 01bDetail 01 - Neon Ligh ng Detail Sec on NL-1
N.T.S
250
0
250 12
17
80mm RADIUS CORNERS
0
80mm RADIUS CORNERS
INSET MESH COVER TO LIGHTBOX
(P.COAT SLATE GREEN COLOUR) POWDERCOATED ALUMINIUM LIGHTBOX
HOUSING - SLATE GREEN COLOUR
CUSTOM NEON LIGHTING 'foster & INSET MESH COVER TO LIGHTBOX
black' VERTICAL LOGO - REFER CLIENT (P.COAT SLATE GREEN COLOUR) 100 300
LOGO DETAILS
CUSTOM NEON LIGHTING 'foster &
black' VERTICAL LOGO - REFER CLIENT 40mm (NOM) RADIUS CORNERS
1,400
1,400
SOLID BACKING TO LOGO (MATTE
GREEN SLATE COLOUR) LOGO DETAILS POWDERCOATED ALUMINIUM LIGHTBO
HOUSING - SLATE GREEN COLOUR (REFE
POWDERCOATED ALUMINIUM LIGHTBOX ELEVATION 02 FOR LOCATION)
HOUSING - SLATE GREEN COLOUR SOLID BACKING TO LOGO (MATTE
GREEN SLATE COLOUR) INSET MESH COVER TO LIGHTBOX (P.CO
300
NOMINAL 10mm DIA POSTS SLATE GREEN COLOUR)
(CONCEALED FIXING TO WALL CUSTOM NEON LIGHTING 'coffee cup'
BEHIND TILE CLADDING) LOGO - REFER CLIENT LOGO DETAILS
BACK TO WALL MOUNTED
WITH CONCEALLED
SOLID BACKING PLATE BEHIND
(GREEN SLATE COLOUR)
BACK FIXED TO WALL (TO BUILDERS DET
02 Detail 02 - Neon Ligh ng Detail NL-2A
N.T.S 03 Detail 02 - Neon Ligh ng Detail NL-2B
N.T.S 04 Detail 04 - Neon Ligh ng Detail NL-3
N.T.S
ALL DETAILS ARE TO BE CONFRIMED BY
BUILDERS + ENGINEER ETC - ALL SIZING
SHOWN IS NOMINAL AND TBC
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Details 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder N.T.S B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 14 /22
Page 15
A B
5,774
2,160 3,614
NO VISIBLE GUTTERING (AS PER EXISTING STRUTURE - INSTALLATION TO COMPLY WITH
MANUFACTURES SPEC. - REFER SECTION & DETAILS (SUBJECT TO APPROVAL)
1 1
H
) IT
AL Y W
OV PL
PR M
AP CO
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR
TO TO
SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY
CT N
WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS
JE TIO
(NOM)
UB LA
1,395
(S AL
ILS ST
TA - IN
OM 9
DE E
(N 3,05
)
& UR C
N T
L
IO RU
2,800
CT ST
2,165
(NOM)
SE GN
ER TI
EF XIS
-R E
2,515
2,515
C. ER
PE S P
NL-1
S S (A
RF ROOF TILE @
RE NG
C
L
TU RI
15.5° ROOF PITCH
AC TTE
UF U
APPROX 8m2
AN E G
M IBL
TERRACOTTA (SK1N FINISHED TBC) TILED ROOF -
@ H
S
VI
LE ITC
INSTALLATION TO MANF. DETAILS - ENGINEERING
NO
I
T P2 ADVICE REQUIRED FOR LOW PITCH
F
O OF 4.5m
O
R RO OX ROOF TILE CONNECTION
RF .5° APPR
ON HIP TO BUILDER AND
MANUFACTURER DETAIL
15
229
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR
32 OM
(N
SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY WITH SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY WITH
4 )
MANUFACTURES SPEC. - REFER SECTION & DETAILS MANUFACTURES SPEC. - REFER SECTION & DETAILS
121
300
2 2
PAN METAL FLASHED ROOF - TERRACOTTA
COLOUR (TO BUILDERS DETAILS)
AC (WALL MOUNTED SYSTEM WITH
CUSTOMISED BRACKETS TO ENSURE AC HEIGHT
DOES NOT PROTUDE ABOVE TOP OF ROOF)
5,544
229 2,973 2,572
5,774
A B
3.11Roof Layout
1:20
Revision Notes. Project Client
0 1 2
Drawing
5
Date
10
Author
reitsma
Issue B - 23.06.2025
- Increase Awning Window heights
Figured dimensions only are to be taken from this drawing.
All dimensions, bearings, exis ng services, mandatory council
All works must comply with NCC, local authority and all
relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Roof Layout 1:20
24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 15 /22
Page 16
FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
FILL LEGEND
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS, CASHDRAWER, SINK, JUG RINERS ETC) TO
BE CONFIRM BY CLIENTS PRIOR TO CABINETRY CONSTRUCTION
EXISTING CEILING
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR PLUMBING AND POWER SERVICES
2350 CEILING
(FC - FEATURE CEILING FRAMING)
5,267
2350 CEILING
1,964 2,953 350 (COVERED BY CABINETRY)
2,108 2,889 270 2400 CEILING
(RECESSED LIGHTBOX)
MESH BULKHEAD
(GREEN COLOUR FINISH)
350
350
350
50
375
7
77
2,
AC-S
50
1,950
3 FW-E
375
26
2,
1,600
2,400
2,400
1,750
50
FW-E
375
50
375
150
300 50
450
300
300
+ FW-E
508 299 50 450 50 450 50 530 50 530 50 530 50 530 50 360 50 360 50 270
508 299 4,190 270
5,267
3.12Reflected Ceiling1:20
Revision Notes. Project Client
0 1 2
Drawing
5
Date
10
Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Reflected Ceiling 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 16 /22
The text continues on page 17.
Used in these records
4707_FOSTER AND BLACK - Working Drawings ISSUE B.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.