GENERAL - CODE LEGEND FINISHES - CODE LEGEND GENERAL CONSTRUCTION NOTES
A AWNING WINDOW (SOLID) AWNING WINDOW - WITH FEATURE SK1N CLADDING OVER CB-D CABINETRY - DARK COMPACT LAMINATE CABINETRY - DARK (COLOUR TBC) GENERAL NOTES
AC AC UNIT (EXTERNAL) EXISTING AC CONDENSOR UNIT RELOCATED - NEW WALL BRACKETS (TO BE SLIM CB-G CABINETRY - GREEN COMPACT LAMINATE CABINETRY - GREEN SLATE ( TBC) DO NOT SCALE DIMENSIONS. CHECK AND VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT.
PROFILE) EXISTING FLOORING TO REMAIN THESE PLANS ARE TO BE READ IN CONJUCTION WITH ALL CONSULTANT DOCUMENTATION.
FL EXISTING FLOORING TO BE REVIEWED ONSITE AND REMAIN (TBC BY CLIENT)
AC-S AC - SPLIT SYSTEM EXISTING AC SPLIT SYSTEM TO BE REPOSITIONED TO ALLOW FOR NEW WINDOW - WITHIN TENANCY - TBC
ALL WINDOWS / OPENINGS TO BE VERIFIED AGAINST FLOOR PLANS AND ELEVATIONS BY CONTRACTOR.
(REPOSITIONED) UNIT TO BE PAINTED DARK COLOUR MSH-G PERFORATED MESH - GREEN POWDERCOATED PERFORATED MESH SCREENING TO MATCH PC-G DISCREPANCIES ARE TO BE REPORTED TO THE DESIGNER PRIOR TO COMMENCEMENT.
BB BATCH BREW LOCATION PERFORATED MESH -
MSH-T POWDERCOATED PERFORATED MESH SCREENING TO MATCH PC-T ALL NE W WORK TO COMPLY WITH THE NCC, THESE DRAWINGS AND ALL OTHER RELEVANT TECHNICAL LITERATURE FOR THIS WIND
750mm (NOM) HIGH WAITING BENCH (ST-T) WITH SEMI-CONCEALED WALL TERRACOTTA
BEN WAITING BENCH MOUNTED SUPPORT STRUCT. UNDER (CIRCULAR HOLLOW SECTIONS - PC-T FINISH) - CATEGORY.
PAC 2PAC - GREEN GREEN SLATE TO MATCH CABINETRY - TBC BY CLIENTS
FINAL DETAILS/FIXING TBC BY MANF. CONFIRM PLANS AGAINST EXISTING STRUCTURE PRIOR TO SITE WORKS - CONFIRMATION OF ALL EXISTING ELEMENTS (WALLS, COLUMNS
PC-G POWDERCOATED - GREEN TO MATCH GREEN SLATE CABINETRY COLOUR (CB-G)
BIN BIN (LOCATION) ROOFS, CEILING, FOORS, FLOORING, WINDOWS, SERVICES ETC)
PC-T POWDERCOATED - TERRACOTTA TO MATCH FEATURE CLADDING WRITTEN AUTHORISATION TO BE OBTAINED BY BODY CORPORATE PRIOR TO COMMENCEMENT OF ANY ONSITE/OFF SITE BUILDING
CG COFFEE GRINDERS
PT-D PAINTED - DARK COLOUR (TBC) LEVEL 5 FINISH (TBC BY BUILDER) WORKS
CHS CHS COLUMN UNDER BENCH CHS SUPPORT POST (DARK COLOUR TBC) 50 mm DIA NOM - REFER
ENG. DETAILS PT-G PAINTED - GREEN SLATE PAINTED PLASTERBOARD - GREEN SLATE (TBC) ENGINEERING NOTES
TERRACOTTA (SK1N FINISHED) TILED CLADDING OVER BATTENING SYSTEM - BRICKWORKS - SK1N POTENZA TERRACOTTA TILING TBC SUBJECT ENGINEERING REFER TO ENGINEERS DETAILS FOR:
CL CLADDING - TERRACOTTA SK1N SK1N TERRACOTTA TILING TIEDOWN, BRACING, FRAMING SCHEDULE, ROOF FRAMING AND TRUSS DETAILS, WIND CATEGORY,
INSTALLATION TO MANF. DETAILS ADVICE
CM COFFEE MACHINE ST-T STONE - TERRAZZO NATURAL STONE TERRAZZO ROSSO (TBC) PLUMBING AND DRAINAGE
CUP'B STORAGE CUPBOARD WITH ADJUSTABLE SHELVES - REFER CABINET MAKER TDK DECKING (TO REMAIN) ### DARK STAINED TIMBER DECKING - REF. INT. SELECTIONS TO COMPLY WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY
SEWER LOCATION AND CONNECTION POINT TBC ON SITE BY BUILDER PRIOR TO CONSTRUCTION
EDB ELECTRICAL DISTRIBUTION EXISTING LOCATION TO REMAIN - HOUSING BOX TO BE PAINTED TO MATCH
BOARD CLADDING COLOUR FLOOR PLAN
FC FEATURE CEILING FRAMING PAC FINISH EXISTING AC SYSTEM TO BE REUSED (RELOCATE EXT. AC CONDENSER) REFER TO BUILDERS/ AC SPECIALIST FOR FINAL DETAILS
FW-E FLOOR WASTE - EXISTING APPROXIMATE LOCATION TO REMAIN LIGHTING - CODE LEGEND ELEVATION / SECTION GENERAL NOTES
ALL R.L'S NOTED ARE NOMINAL & SUBJECT EXISTING R.L'S - TBC ONSITE BY BUILDER
HOT WATER SYSTEM -
HWS LB-C LIGHT BOX (CEILING) CUSTOM CEILING LIGHT BOX - DETAILS BY SPECIALIST PROPOSED RENOVATION / MODIFICATIONS TO STRICTLY NOT EXCEED THE HEIGHT OF EXISTING STRUCTURE
EXISTING
- ALL CLADDING SYSTEMS NOTED TO BE FIXED IN ACCORDANCE WITH RELEVANT MANUFACTURES'S SPECIFICATIONS.
ICE MACHINE - ALLOW FOR OPEN CABINETRY SURROUNDING FOR AIR FLOW LB-W LIGHT BOX (WALL) CUSTOM WALL LIGHT BOX FOR PRODUCT BACK LIGHTING - DETAILS BY SPECIALIST - STRUCTURAL ELEMENTS TO BE DETERMINED BY STRUCTURAL ENGINEER AND BUILDER
ICE ICE MACHINE (LOCATION)
(BEHIND) ML MENU LIGHT (ADJUSTABLE) LED ADJUSTABLE LIGHT - FOR MENU BOARD - ALUMINIUM FRAMED WINDOWS/OPENINGS AND DOORS COLOUR TBC BY CLIENT - REFER 3D MODEL
KC KNOCK CHUTE KNOCK CHUTE (BIN UNDER) CUT INTO BENCHTOP - WINDOW SIZES/HEIGHTS SHOWN NOMINAL ONLY ARE TO BE CONFIRMED BY A SITE MEASURE
3D NEON SIGNAGE (ROOF MOUNTED) - '3D COFFEE CUP' LOGO/BRANDING - WITH - DETAILS TO MITIGATE CONDENSATION AND COMPLY WITH ALL RELEVANT CODES - REF. BUILDERS DETAIL
MENU BOARD - WALL MOUNTED ALUMINIMUM NL-1 NEON LIGHT 01 - 3D CUP PC-T MESH SURROUND - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAILS * COLOURS SHOWN ARE INDICATIVE -TO BE CONFIRMED BY CLIENT AND AGAINST DESIGN SPECIFICATIONS PRIOR TO ORDERING
MB MENU BOARD STRIPS WITH MAGNETIC (TBC) INTERCHANGABLE SHEETS
LETTERS - SEE DETAILS (ALL MATTE WHITE) NEON SIGNAGE (SIDE WALL MOUNTED) - FEATURE VERTAL 'foster & black' - IN (PC-T) ROOF NOTES
600mm MILK JUG RINSER (UNDER MOUNT) - CABINETRY BELOW TO BE CUT/ALLOW NL-2A NEON LIGHT 02 - VERT. BOX/HOUSING WITH MESH (PC-T) OVER - WALL MOUNTED FIXING POINT TO SIDED - TILED ROOF TO BE 15.5° (NOM). TERRACOTTA STYLE TILES (SELECTION TBC BY CLIENT) TO SUIT ROOF SLOPE, LOCATION + CAPACITY
MJR MILK JUG RINSER OF HOUSING - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL REQUIREMENTS
FOR PLUMBING - ALL STORMWATER LAYOUTS ARE TO BE DETAILED BY BUILDER+PLUMBING SUPPLIER TO ENSURE ALL WORK TO COMPLY WITH
OHC OVER HEAD CABINETRY NEON SIGNAGE (BACK TO WALL MOUNTED) - FEATURE VERTAL 'foster & black' - IN AS3500.3.2:2003
NL-2B NEON LIGHT 02 - VERT. (PC-T) BOX/HOUSING WITH MESH (PC-T) OVER - BACK TO WALL MOUNTED FIXING - - FLASHING SYSTEMS TO BE DESIGNED + INSTALLED IN CONSULTATION WITH MANUF. DETAILS
OVER HEAD CABINETRY - OVERHEAD CABINETRY - TO CONCEAL SPLIT AC SYSTEM - MESH FACE AND BASE REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL
OHC-M MESH PANELS FOR AIR FLOW
NEON SIGNAGE (WALL MOUNTED) - 'COFFEE CUP' LOGO/BRANDING - IN BOX/
PD PLUMBING DUCT/VOID NL-3 NEON LIGHT 03 - SQUARE HOUSING (POWDERCOATED PC-T) WITH PC-T MESH OVER
PMF PAN METAL FLASHING PAN METAL FLASHED ROOF - TERRACOTTA COLOUR (TO BUILDERS DETAILS) - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL
POS POINT OF SALE POINT OF SALE - POS SYSTEM/COMPUTER ON STAND - FIXED TO COUNTER
PRIVACY SCREENING TO WASH UP ZONE - MESH SHEETING WITH PERIMETER FRAME
PS PRIVACY SCREEN (PC-G FINISH) - FIXED TO TOP OF STONE BENCH (SEMI
CONCEALED FIXINGS)
REF REFRIGERATOR - (SUPPLIED BY OWNER)
UNDERBENCH
TERRACOTTA (SK1N FINISHED TBC) TILED ROOF - INSTALLATION TO MANF. DETAILS -
RF TERRACOTTA TILED ROOF ENGINEERING ADVICE REQUIRED FOR LOW PITCH
RO REVERSE OSMOSIS SYSTEM WALL MOUNTED REVERSE OSMOSIS WATER FILTER SYSTEM - SUPPLIED BY OWNER
SA SMOKE ALARM PROPOSED SMOKE ALARM LOCATION - EXACT LOCATION TBC ON SITE BY SPECIALIST -
TO COMPLY WITH NCC 9.5
SH-D1 SHELVING - DISPLAY (MAIN) FEATURE DISPLAY SHELVING (CB-G FINISH) - WITH LB BEHIND
SH-D2 SHELVING - DISPLAY (POS) VERT. DISPLAY SHELVES FROM NAT. STONE (ST-T) @ POINT OF SALE (WITH LB BEHIND)
SH-O SHELVING - OVERHEAD OPEN OVERHEAD SHELVING
SK-1 SINK (DOUBLE) RECESSED SINK (DARK - SELECTION BY CLIENT)
SK-2 SINK (SINGLE) RECESSED SINK (DARK - SELECTION BY CLIENT)
TIL TIL (POS) CASH DRAW / RECEIPT PRINT (DETAILS BY OWNER)
TOW TOP OF WALL TBC BY BUILDER ONSITE
TP1 TAP DECK MOUNTED - MATTE BLACK TAP+MIXER (TO MATCH TOUCHLESS BOOMERANG)
TP2 TAP - SENSOR SENSOR TAP - TOUCHLESS BOOMERANG (DECK MOUNTED) - MATTE BLACK
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Codes 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder N/A B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 2 /22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
4707_FOSTER AND BLACK - Working Drawings ISSUE B.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.