    GENERAL - CODE LEGEND                                                                                                           FINISHES - CODE LEGEND                                                                                                               GENERAL CONSTRUCTION NOTES
A           AWNING WINDOW (SOLID)       AWNING WINDOW - WITH FEATURE SK1N CLADDING OVER                                            CB-D           CABINETRY - DARK                            COMPACT LAMINATE CABINETRY - DARK (COLOUR TBC)                             GENERAL NOTES
AC          AC UNIT (EXTERNAL)          EXISTING AC CONDENSOR UNIT RELOCATED - NEW WALL BRACKETS (TO BE SLIM                       CB-G           CABINETRY - GREEN                           COMPACT LAMINATE CABINETRY - GREEN SLATE ( TBC)                            DO NOT SCALE DIMENSIONS. CHECK AND VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT.
                                        PROFILE)                                                                                                  EXISTING FLOORING TO REMAIN                                                                                            THESE PLANS ARE TO BE READ IN CONJUCTION WITH ALL CONSULTANT DOCUMENTATION.
                                                                                                                                   FL                                                         EXISTING FLOORING TO BE REVIEWED ONSITE AND REMAIN (TBC BY CLIENT)
AC-S        AC - SPLIT SYSTEM           EXISTING AC SPLIT SYSTEM TO BE REPOSITIONED TO ALLOW FOR NEW WINDOW -                                     WITHIN TENANCY - TBC
                                                                                                                                                                                                                                                                         ALL WINDOWS / OPENINGS TO BE VERIFIED AGAINST FLOOR PLANS AND ELEVATIONS BY CONTRACTOR.
            (REPOSITIONED)              UNIT TO BE PAINTED DARK COLOUR                                                             MSH-G          PERFORATED MESH - GREEN                     POWDERCOATED PERFORATED MESH SCREENING TO MATCH PC-G                       DISCREPANCIES ARE TO BE REPORTED TO THE DESIGNER PRIOR TO COMMENCEMENT.
BB          BATCH BREW LOCATION                                                                                                                   PERFORATED MESH -
                                                                                                                                   MSH-T                                                      POWDERCOATED PERFORATED MESH SCREENING TO MATCH PC-T                       ALL NE W WORK TO COMPLY WITH THE NCC, THESE DRAWINGS AND ALL OTHER RELEVANT TECHNICAL LITERATURE FOR THIS WIND
                                        750mm (NOM) HIGH WAITING BENCH (ST-T) WITH SEMI-CONCEALED WALL                                            TERRACOTTA
BEN         WAITING BENCH               MOUNTED SUPPORT STRUCT. UNDER (CIRCULAR HOLLOW SECTIONS - PC-T FINISH) -                                                                                                                                                         CATEGORY.
                                                                                                                                   PAC            2PAC - GREEN                                GREEN SLATE TO MATCH CABINETRY - TBC BY CLIENTS
                                        FINAL DETAILS/FIXING TBC BY MANF.                                                                                                                                                                                                CONFIRM PLANS AGAINST EXISTING STRUCTURE PRIOR TO SITE WORKS - CONFIRMATION OF ALL EXISTING ELEMENTS (WALLS, COLUMNS
                                                                                                                                   PC-G           POWDERCOATED - GREEN                        TO MATCH GREEN SLATE CABINETRY COLOUR (CB-G)
BIN         BIN (LOCATION)                                                                                                                                                                                                                                               ROOFS, CEILING, FOORS, FLOORING, WINDOWS, SERVICES ETC)
                                                                                                                                   PC-T           POWDERCOATED - TERRACOTTA                   TO MATCH FEATURE CLADDING                                                  WRITTEN AUTHORISATION TO BE OBTAINED BY BODY CORPORATE PRIOR TO COMMENCEMENT OF ANY ONSITE/OFF SITE BUILDING
CG          COFFEE GRINDERS
                                                                                                                                   PT-D           PAINTED - DARK COLOUR (TBC)                 LEVEL 5 FINISH (TBC BY BUILDER)                                            WORKS
CHS         CHS COLUMN                  UNDER BENCH CHS SUPPORT POST (DARK COLOUR TBC) 50 mm DIA NOM - REFER
                                        ENG. DETAILS                                                                               PT-G           PAINTED - GREEN SLATE                       PAINTED PLASTERBOARD - GREEN SLATE (TBC)                                   ENGINEERING NOTES
                                        TERRACOTTA (SK1N FINISHED) TILED CLADDING OVER BATTENING SYSTEM -                                                                                     BRICKWORKS - SK1N POTENZA TERRACOTTA TILING TBC SUBJECT ENGINEERING        REFER TO ENGINEERS DETAILS FOR:
CL          CLADDING - TERRACOTTA                                                                                                  SK1N           SK1N TERRACOTTA TILING                                                                                                 TIEDOWN, BRACING, FRAMING SCHEDULE, ROOF FRAMING AND TRUSS DETAILS, WIND CATEGORY,
                                        INSTALLATION TO MANF. DETAILS                                                                                                                         ADVICE
CM          COFFEE MACHINE                                                                                                         ST-T           STONE - TERRAZZO                            NATURAL STONE TERRAZZO ROSSO (TBC)                                         PLUMBING AND DRAINAGE
CUP'B       STORAGE CUPBOARD            WITH ADJUSTABLE SHELVES - REFER CABINET MAKER                                              TDK            DECKING (TO REMAIN)                         ### DARK STAINED TIMBER DECKING - REF. INT. SELECTIONS                     TO COMPLY WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY
                                                                                                                                                                                                                                                                         SEWER LOCATION AND CONNECTION POINT TBC ON SITE BY BUILDER PRIOR TO CONSTRUCTION
EDB         ELECTRICAL DISTRIBUTION     EXISTING LOCATION TO REMAIN - HOUSING BOX TO BE PAINTED TO MATCH
            BOARD                       CLADDING COLOUR                                                                                                                                                                                                                  FLOOR PLAN
FC          FEATURE CEILING FRAMING     PAC FINISH                                                                                                                                                                                                                       EXISTING AC SYSTEM TO BE REUSED (RELOCATE EXT. AC CONDENSER) REFER TO BUILDERS/ AC SPECIALIST FOR FINAL DETAILS
FW-E        FLOOR WASTE - EXISTING      APPROXIMATE LOCATION TO REMAIN                                                              LIGHTING - CODE LEGEND                                                                                                               ELEVATION / SECTION GENERAL NOTES
                                                                                                                                                                                                                                                                         ALL R.L'S NOTED ARE NOMINAL & SUBJECT EXISTING R.L'S - TBC ONSITE BY BUILDER
            HOT WATER SYSTEM -
HWS                                                                                                                                LB-C           LIGHT BOX (CEILING)                   CUSTOM CEILING LIGHT BOX - DETAILS BY SPECIALIST                                 PROPOSED RENOVATION / MODIFICATIONS TO STRICTLY NOT EXCEED THE HEIGHT OF EXISTING STRUCTURE
            EXISTING
                                                                                                                                                                                                                                                                         - ALL CLADDING SYSTEMS NOTED TO BE FIXED IN ACCORDANCE WITH RELEVANT MANUFACTURES'S SPECIFICATIONS.
                                        ICE MACHINE - ALLOW FOR OPEN CABINETRY SURROUNDING FOR AIR FLOW                            LB-W           LIGHT BOX (WALL)                      CUSTOM WALL LIGHT BOX FOR PRODUCT BACK LIGHTING - DETAILS BY SPECIALIST          - STRUCTURAL ELEMENTS TO BE DETERMINED BY STRUCTURAL ENGINEER AND BUILDER
ICE         ICE MACHINE (LOCATION)
                                        (BEHIND)                                                                                   ML             MENU LIGHT (ADJUSTABLE)               LED ADJUSTABLE LIGHT - FOR MENU BOARD                                            - ALUMINIUM FRAMED WINDOWS/OPENINGS AND DOORS COLOUR TBC BY CLIENT - REFER 3D MODEL
KC          KNOCK CHUTE                 KNOCK CHUTE (BIN UNDER) CUT INTO BENCHTOP                                                                                                                                                                                        - WINDOW SIZES/HEIGHTS SHOWN NOMINAL ONLY ARE TO BE CONFIRMED BY A SITE MEASURE
                                                                                                                                                                                        3D NEON SIGNAGE (ROOF MOUNTED) - '3D COFFEE CUP' LOGO/BRANDING - WITH            - DETAILS TO MITIGATE CONDENSATION AND COMPLY WITH ALL RELEVANT CODES - REF. BUILDERS DETAIL
                                        MENU BOARD - WALL MOUNTED ALUMINIMUM                                                       NL-1           NEON LIGHT 01 - 3D CUP                PC-T MESH SURROUND - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAILS        * COLOURS SHOWN ARE INDICATIVE -TO BE CONFIRMED BY CLIENT AND AGAINST DESIGN SPECIFICATIONS PRIOR TO ORDERING
MB          MENU BOARD                  STRIPS WITH MAGNETIC (TBC) INTERCHANGABLE                                                                                                       SHEETS
                                        LETTERS - SEE DETAILS (ALL MATTE WHITE)                                                                                                         NEON SIGNAGE (SIDE WALL MOUNTED) - FEATURE VERTAL 'foster & black' - IN (PC-T)   ROOF NOTES
                                        600mm MILK JUG RINSER (UNDER MOUNT) - CABINETRY BELOW TO BE CUT/ALLOW                      NL-2A          NEON LIGHT 02 - VERT.                 BOX/HOUSING WITH MESH (PC-T) OVER - WALL MOUNTED FIXING POINT TO SIDED           - TILED ROOF TO BE 15.5° (NOM). TERRACOTTA STYLE TILES (SELECTION TBC BY CLIENT) TO SUIT ROOF SLOPE, LOCATION + CAPACITY
MJR         MILK JUG RINSER                                                                                                                                                             OF HOUSING - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL                 REQUIREMENTS
                                        FOR PLUMBING                                                                                                                                                                                                                     - ALL STORMWATER LAYOUTS ARE TO BE DETAILED BY BUILDER+PLUMBING SUPPLIER TO ENSURE ALL WORK TO COMPLY WITH
OHC         OVER HEAD CABINETRY                                                                                                                                                         NEON SIGNAGE (BACK TO WALL MOUNTED) - FEATURE VERTAL 'foster & black' - IN       AS3500.3.2:2003
                                                                                                                                   NL-2B          NEON LIGHT 02 - VERT.                 (PC-T) BOX/HOUSING WITH MESH (PC-T) OVER - BACK TO WALL MOUNTED FIXING -         - FLASHING SYSTEMS TO BE DESIGNED + INSTALLED IN CONSULTATION WITH MANUF. DETAILS
            OVER HEAD CABINETRY -       OVERHEAD CABINETRY - TO CONCEAL SPLIT AC SYSTEM - MESH FACE AND BASE                                                                            REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL
OHC-M       MESH                        PANELS FOR AIR FLOW
                                                                                                                                                                                        NEON SIGNAGE (WALL MOUNTED) - 'COFFEE CUP' LOGO/BRANDING - IN BOX/
PD          PLUMBING DUCT/VOID                                                                                                     NL-3           NEON LIGHT 03 - SQUARE                HOUSING (POWDERCOATED PC-T) WITH PC-T MESH OVER
PMF         PAN METAL FLASHING          PAN METAL FLASHED ROOF - TERRACOTTA COLOUR (TO BUILDERS DETAILS)                                                                                 - REFER SIGNAGE DESIGNER SPEC. SEE PERSPECTIVE+DETAIL
POS         POINT OF SALE               POINT OF SALE - POS SYSTEM/COMPUTER ON STAND - FIXED TO COUNTER
                                        PRIVACY SCREENING TO WASH UP ZONE - MESH SHEETING WITH PERIMETER FRAME
PS          PRIVACY SCREEN              (PC-G FINISH) - FIXED TO TOP OF STONE BENCH (SEMI
                                        CONCEALED FIXINGS)
REF         REFRIGERATOR -              (SUPPLIED BY OWNER)
            UNDERBENCH
                                        TERRACOTTA (SK1N FINISHED TBC) TILED ROOF - INSTALLATION TO MANF. DETAILS -
RF          TERRACOTTA TILED ROOF       ENGINEERING ADVICE REQUIRED FOR LOW PITCH
RO          REVERSE OSMOSIS SYSTEM      WALL MOUNTED REVERSE OSMOSIS WATER FILTER SYSTEM - SUPPLIED BY OWNER
SA          SMOKE ALARM                 PROPOSED SMOKE ALARM LOCATION - EXACT LOCATION TBC ON SITE BY SPECIALIST -
                                        TO COMPLY WITH NCC 9.5
SH-D1       SHELVING - DISPLAY (MAIN)   FEATURE DISPLAY SHELVING (CB-G FINISH) - WITH LB BEHIND
SH-D2       SHELVING - DISPLAY (POS)    VERT. DISPLAY SHELVES FROM NAT. STONE (ST-T) @ POINT OF SALE (WITH LB BEHIND)
SH-O        SHELVING - OVERHEAD         OPEN OVERHEAD SHELVING
SK-1        SINK (DOUBLE)               RECESSED SINK (DARK - SELECTION BY CLIENT)
SK-2        SINK (SINGLE)               RECESSED SINK (DARK - SELECTION BY CLIENT)
TIL         TIL (POS)                   CASH DRAW / RECEIPT PRINT (DETAILS BY OWNER)
TOW         TOP OF WALL                 TBC BY BUILDER ONSITE
TP1         TAP                         DECK MOUNTED - MATTE BLACK TAP+MIXER (TO MATCH TOUCHLESS BOOMERANG)
TP2         TAP - SENSOR                SENSOR TAP - TOUCHLESS BOOMERANG (DECK MOUNTED) - MATTE BLACK




                                                      Revision                                             Notes.                                                                                                                                Project                           Client                                 Drawing                                    Date                            Author


                   reitsma
                                                      Issue B - 23.06.2025                                 Figured dimensions only are to be taken from this drawing.            All works must comply with NCC, local authority and all
                                                      - Increase Awning Window heights                     All dimensions, bearings, exis ng services, mandatory council         relevant geographical/wind category requirements. All           FOSTER & BLACK - HASTINGS         FOSTER & BLACK                         Codes                                      24/06/2025                        JTL
                                                      - Change Awnings to Fluted Glass ( nted)
                                                      - reduce overhead shelves                            restraints/requirements and proposed levels are to be checked and     cut and fill ba ers are indica ve only and must be                                                                                                                                   Scale                          Revision
                                                                                                           verified on site by builder/client prior to commencement of works.     established and verified by builder/client in rela on to
                                                                                                           Any discrepancies must be communicated to the designer prior to       proposed slab and/or floor levels                                SHOP 8 (No. 18) HASTINGS ST. Builder                                                                                N/A                                 B
                                                                                                                                                                                                                                           N




        +61 493 062 182       13 Ridgewood Road.                                                           commencement of works. Please note, builder specifica ons and          These drawings are to be read in conjunc on with other                                       ADDITION PROJECTS                           Stage
                                       Caloundra                                                           signed contracts to take precedence over all Reitsma documenta on.    relevant consultants drawings and reports.                      NOOSA HEADS                  P: 0481 000 118                             CONSTRUCTION                               Project Number           Sheet Number
        [email protected]            QLD, 4551
        www.reitsma.com.au              Australia
                                                                                                           © Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
                                                                                                           QBCC Lic. No. 1234490 BDAQ Member
                                                                                                                                                                                                                                                 QLD     4567                                                             DOCUMENTATION                              4707                           2 /22

Used in these records

About this file

File size
15.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

4707_FOSTER AND BLACK - Working Drawings ISSUE B.pdf · 15.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.