FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING 1 2
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS, NOMINAL ROOF TILE / CLADDING 2,580
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS CONNECTION DETAIL
PRIOR TO CABINETRY CONSTRUCTION TILTING BATTEN (BY BUILDER) AS PER MANF. SPEC
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR BRICKWORKS - SK1N POTENZA TERRACOTTA
PLUMBING AND POWER SERVICES TILING TBC SUBJECT ENGINEERING ADVICE
ROOF BATTEN
STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS
ROOF CONSTRUCTION BY ENG. TO TOP OR SIDES OF TILED ROOF (TYPICAL) -
INSTALLATION TO COMPLY WITH MANUFACTURES
WATERPROOFING MEMBRANE SPEC. - REFER SECTION & DETAILS
APPROX. TOP OF EXISTING3.400
SK1N
CL PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
SK1N TOP HAT FIXING
INSULATION
PITCH EXISTING AC CONDENSOR UNIT
WATERPROOFING MEMBRANE
5.5° ROOF RELOCATED - NEW WALL
820
R F@1 BRACKETS (TO BE SLIM PROFILE)
NO VISIBLE GUTTERING (AS PER EXISTING NEW ROOF CONSTRUCTION
STRUTURE - INSTALLATION TO COMPLY WITH TO ENGINEERS DETAILS
PMF
MANUFACTURES SPEC. - REFER SECTION &
DETAILS (SUBJECT TO APPROVAL)
50 100
150
PROPOSED STRUCTURAL PERIMETER BEAM TO LB-C
PROVIDE UPSTAND TO NEW TRUSSED ROOF - PAC
NEW STRUCTURE TO ACHIEVE INCREASE FC CEILING HEIGHT 2.350
CEILING HEIGHTS - REFER ENGINEERS DETAILS MSH-G
OHC-M EXISTING AC SPLIT SYSTEM TO BE REPOSITIONED
AC-S 200 TO ALLOW FOR NEW WINDOW - UNIT TO BE
SH-D1 PAINTED DARK COLOUR
PC-T PT-G CL
A
SH-D1
3,320
AWNING WINDOW WITH TINTED+FLUTED
GLASS - DUAL COLOUR FRAMING - SILL FRAME
LB-W
TO BE CUSTOM TERRACOTTA COLOUR -
WINDOW / GLASS FRAME SURROUND DARK
COLOUR - DETAILS BY OTHERS
SH-D1
SLIM PROFILE ALUMINIUM POWDERCOATED
2,350
EDB
2,350
PERIMETER FRAMING AROUND OPENINGS (PC-T
COLOUR) TO CAP ENDS OF SK1N TILE CLADDING
MSH-T
PS TP1 TP2 SH-D1 APPROXIMATE LOCATION OF EXISTING SERVICES
A ST-T - HOUSING TO BE COLOUR MATCHED TO
PROPOSED SK1N CLADDING COLOUR
PT-G CB-G CB-G
REF - (SUPPLIED
BY OWNER) CUP'B CUP'B
OPEN CAVITY ZONE FOR AIR FLOW/
CIRCULATION TO REFRIDGERATOR MOTOR -
FINAL SPACE TBC AGAINST MANUF. DETAILS CL ALUMINIUM PERIMETER KICK (PC-T
FINISH) - TO ALLOW FOR CLADDING
FINISH TO STOP ABOVE FGL
EXISTING FLOORING TO REMAIN
ALUMINIUM PERIMETER KICK (PC-T WITHIN TENANCY - TBC
FINISH) - TO ALLOW FOR CLADDING FLOOR LEVEL 0.000 (EXISTING)
FINISH TO STOP ABOVE FGL EXISTING DECKING TO REMAIN
3.5Sec on 011:20
Revision Notes. Project Client Drawing Date Author
reitsma
Issue B - 23.06.2025 Figured dimensions only are to be taken from this drawing. All works must comply with NCC, local authority and all
- Increase Awning Window heights All dimensions, bearings, exis ng services, mandatory council relevant geographical/wind category requirements. All FOSTER & BLACK - HASTINGS FOSTER & BLACK Sec on 01 24/06/2025 JTL
- Change Awnings to Fluted Glass ( nted)
- reduce overhead shelves restraints/requirements and proposed levels are to be checked and cut and fill ba ers are indica ve only and must be Scale Revision
verified on site by builder/client prior to commencement of works. established and verified by builder/client in rela on to
Any discrepancies must be communicated to the designer prior to proposed slab and/or floor levels SHOP 8 (No. 18) HASTINGS ST. Builder 1:20 B
N
+61 493 062 182 13 Ridgewood Road. commencement of works. Please note, builder specifica ons and These drawings are to be read in conjunc on with other ADDITION PROJECTS Stage
Caloundra signed contracts to take precedence over all Reitsma documenta on. relevant consultants drawings and reports. NOOSA HEADS P: 0481 000 118 CONSTRUCTION Project Number Sheet Number
[email protected] QLD, 4551
www.reitsma.com.au Australia
© Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
QBCC Lic. No. 1234490 BDAQ Member
QLD 4567 DOCUMENTATION 4707 9 /22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
4707_FOSTER AND BLACK - Working Drawings ISSUE B.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.