FINAL DETAILS TO SHOPFITTER/CABINET MAKERS SPECIFICATIONS
                                                                                                                                                              B                                                                                                                                   A
ALL CABINETRY TO HAVE ADJUSTABLE SHELVING
                                                                                                                                                                                                                               5,305
FINAL EQUIPEMENT SIZES (FRIDGES, BINS, DISHWASHERS,
CASHDRAWER, SINK, JUG RINERS ETC) TO BE CONFIRM BY CLIENTS
PRIOR TO CABINETRY CONSTRUCTION
ALLOW FOR SERVICES DUCT BEHIND/THROUGH CABINETRY FOR
PLUMBING AND POWER SERVICES                                                                                                                                                                                                     NL-1


                                                                                                                                                                                                                                                                                                                          APPROX. TOP OF EXISTING 3.400
                                                                                                                                                                          [email protected]° ROOF PITCH
                                                       STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR                                                                                                                                                                                                 PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
                                                                                                                                                                      SK1N                                                                                   RF @ 1
                                                          SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY                                                                                                                                                   5.5° RO
                                                             WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS                                                                                                                                                            OF PIT
                                                                                                                                                                                                                                                                                CH




                                                                                                                                                                                                                                                                                                                                                                 970
                                                                                                                                                                                                                      RL 2.602 (NOM)
                                                                  NO VISIBLE GUTTERING (AS PER EXISTING STRUTURE -
                                                               INSTALLATION TO COMPLY WITH MANUFACTURES SPEC. -
                                                                    REFER SECTION & DETAILS (SUBJECT TO APPROVAL)                                                     SK1N                                                                                                                        SK1N
                                                                                                                                                                                                                                                                                                                                          CEILING HEIGHT 2.350


                                                                               SLIM PROFILE ALUMINIUM POWDERCOATED




                                                                                                                                                                                                                                                                                                                                                                          3,320
                                                                            PERIMETER FRAMING AROUND OPENINGS (PC-T




                                                                                                                                                                                                                                                                                                              NL-2A
                                                                                                                                                              NL-2B
                                                                                                                                                1,400




                                                                                                                                                                                                                                        1,280




                                                                                                                                                                                                                                                                                                              1,400
                                                                            COLOUR) TO CAP ENDS OF SK1N TILE CLADDING

                                                                 AWNING WINDOW WITH TINTED+FLUTED GLASS - DUAL




                                                                                                                                                                                                                                                                                                                                                                 2,350
                                                                       COLOUR FRAMING - SILL FRAME TO BE CUSTOM                                                                  A                                                                           A
                                                                     TERRACOTTA COLOUR - WINDOW / GLASS FRAME                                                                                                                                                                                    POS
                                                                      SURROUND DARK COLOUR - DETAILS BY OTHERS                                                                                                                                                                                  NL-3




                                                                                                                                                                                                                                                                                                       300
                                                                                 PROPOSED FRAMING TO BOX OUT EXISTING                                                                                         CL                                                                    CL
                                                                                  STEPPED CORNER - SUBJECT TO APPROVAL




                                                                                                                                                                                                                                        940
                                                                                                                                                880




                                                                                                                                                                                                                                                                                                                 880
                                                                                                                                                                                                                                                                                                       500
                                                                                                                                                                                                                                                                                                                            FLOOR LEVEL 0.000 (EXISTING)


                                                                           ALUMINIUM PERIMETER KICK (PC-T FINISH) - TO
                                                                         ALLOW FOR CLADDING FINISH TO STOP ABOVE FGL




                                                                                                                                                             03 Eleva on 03 (East)
                                                                                                                                                                              1:50




                                                                                                                                                                                        2                                                                1
                                                                                                                                                                                                                      2,580
                                                                              STRICTLY NO VISIBLE METAL CAPPINGS / FLASHINGS TO TOP OR                                                                                 NL-1
                                                                                 SIDES OF TILED ROOF (TYPICAL) - INSTALLATION TO COMPLY
                                                                                    WITH MANUFACTURES SPEC. - REFER SECTION & DETAILS
                                                                                                                                                                                                                                                                                         APPROX. TOP OF EXISTING 3.400
                                                                                                                                                                                                                                                                             PROPOSED TOP OF ROOF R.L. 3.320 (NOM)
                                                                                                   EXISTING AC CONDENSOR UNIT RELOCATED -                                                AC
                                                                                                    NEW WALL BRACKETS (TO BE SLIM PROFILE)                                                         SK1N                        RF @                                                 NO VISIBLE GUTTERING (AS PER
                                                                                                                                                                                                                                      15.5°                                         EXISTING STRUTURE - INSTALLATION
                                                                                                                                                                                                                                            ROOF




                                                                                                                                                                                                                                                                                                                          970
                                                                                                                                                                             RL 2.602 (NOM)                                                      PITCH                              TO COMPLY WITH MANUFACTURES
                                                                                                                                                                                                                                                                                    SPEC. - REFER SECTION & DETAILS
                                                                                                                                                                                                                                                                                    (SUBJECT TO APPROVAL)
                                                                                                                                                                                                                          CL
                                                                                                                                                                                                                                                                                                  CEILING HEIGHT 2.350

                                                                                                   SLIM PROFILE ALUMINIUM POWDERCOATED
                                                                                                PERIMETER FRAMING AROUND OPENINGS (PC-T




                                                                                                                                                                                                                                                                                                                                  3,320
                                                                                                COLOUR) TO CAP ENDS OF SK1N TILE CLADDING




                                                                                                                                                                                                                                                             NL-2B
                                                                                                                                                                                                                                                                     1,400
                                                                                                                                                                                                                                                 1,030
                                                                                        AWNING WINDOW WITH TINTED+FLUTED GLASS - DUAL




                                                                                                                                                                                                                                                                                                                          2,350
                                                                                              COLOUR FRAMING - SILL FRAME TO BE CUSTOM                                                                A
                                                                                            TERRACOTTA COLOUR - WINDOW / GLASS FRAME
                                                                                             SURROUND DARK COLOUR - DETAILS BY OTHERS
                                                                                                                                                                                                                      BEN                                                           PROPOSED FRAMING TO BOX
                                                                                                                                                                                              20




                                                                                                   PROPOSED FRAMING TO BOX OUT EXISTING
                                                                                                    STEPPED CORNER - SUBJECT TO APPROVAL                                                                                                                                            OUT EXISTING STEPPED CORNER
                                                                                                                                                                                                                                                 940                                - SUBJECT TO APPROVAL




                                                                                                                                                                                                                                                                     880
                                                                                                                                                                                                700




                                                                                                                                                                                                                                                                                           FLOOR LEVEL 0.000 (EXISTING)
                                                                                                                                                                                           (NOM)
                                                                                                                                                                                            200




                                                                                                ALUMINIUM PERIMETER KICK (PC-T FINISH) - TO
                                                                                              ALLOW FOR CLADDING FINISH TO STOP ABOVE FGL




                                                   Revision                                                           Notes.
                                                                                                                                                                                       04 Eleva on 04 (South)
                                                                                                                                                                                                       1:50
                                                                                                                                                                                                                                                                                 Project                                    Client
                                                                                                                                                                                                                                                                                                                                                  0       1          2
                                                                                                                                                                                                                                                                                                                                                                         Drawing
                                                                                                                                                                                                                                                                                                                                                                                         5
                                                                                                                                                                                                                                                                                                                                                                                             Date
                                                                                                                                                                                                                                                                                                                                                                                                                        10
                                                                                                                                                                                                                                                                                                                                                                                                                    Author


                 reitsma
                                                   Issue B - 23.06.2025                                               Figured dimensions only are to be taken from this drawing.            All works must comply with NCC, local authority and all
                                                   - Increase Awning Window heights                                   All dimensions, bearings, exis ng services, mandatory council         relevant geographical/wind category requirements. All                                FOSTER & BLACK - HASTINGS                  FOSTER & BLACK                               Eleva ons 3+4       24/06/2025               JTL
                                                   - Change Awnings to Fluted Glass ( nted)
                                                   - reduce overhead shelves                                          restraints/requirements and proposed levels are to be checked and     cut and fill ba ers are indica ve only and must be                                                                                                                                                Scale                 Revision
                                                                                                                      verified on site by builder/client prior to commencement of works.     established and verified by builder/client in rela on to
                                                                                                                      Any discrepancies must be communicated to the designer prior to       proposed slab and/or floor levels                                                     SHOP 8 (No. 18) HASTINGS ST. Builder                                                                          1:50                     B
                                                                                                                                                                                                                                                         N




      +61 493 062 182       13 Ridgewood Road.                                                                        commencement of works. Please note, builder specifica ons and          These drawings are to be read in conjunc on with other                                                            ADDITION PROJECTS                                          Stage
                                     Caloundra                                                                        signed contracts to take precedence over all Reitsma documenta on.    relevant consultants drawings and reports.                                           NOOSA HEADS                  P: 0481 000 118                                            CONSTRUCTION        Project Number   Sheet Number
      [email protected]            QLD, 4551
      www.reitsma.com.au              Australia
                                                                                                                      © Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767
                                                                                                                      QBCC Lic. No. 1234490 BDAQ Member
                                                                                                                                                                                                                                                                                 QLD     4567                                                                            DOCUMENTATION       4707                  8 /22

Used in these records

About this file

File size
15.6 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

4707_FOSTER AND BLACK - Working Drawings ISSUE B.pdf · 15.6 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.