               ENGINEERING
                      Site Access and Driveways
               23.    A sealed access driveway must be provided from Jan Street and Banksia Avenue to all
                      parking and manoeuvring areas of the development. The works must be undertaken
                      generally in accordance with the conditions of this approval and be generally in accordance
                      with ARCOS’ Development Site Plan (OPW-C-301, Rev. A) dated 18 December 2023.
                      Car Parking
               24.    A minimum of 3 car parking spaces must be provided on the site. The works must include a
                      minimum of 2 covered spaces.
                      Stormwater Drainage
               25.    The site must be provided with a stormwater drainage system connecting to a lawful point of
                      discharge. The works must be undertaken generally in accordance with the conditions of
                      this approval, be generally in accordance with ARCOS’ Development Site Plan (OPW-C-301,
                      Rev. A) dated 18 December 2023, and must include in particular:
                      a.      3,000L of on-site rainwater retention per tenancy for reuse purposes.
                      Services
               26.    Underground reticulated electricity and telecommunication services must be provided to
                      each lot in accordance with the standards and requirements of the relevant service provider.
               27.    Unless otherwise stipulated by telecommunications legislation at the time of construction, the
                      development must be provided with all necessary conduits, pits and pipes to accommodate
                      the future connection of optic fibre technology telecommunications.
               28.    Certification must be submitted to Council from all relevant service providers (Energex, NBN
                      and Unitywater) which certifies that the development has met the requirements of this
                      Decision Notice and all applicable legislation at the time of construction.
                      Easements
               29.    Unless otherwise agreed in writing by the relevant service provider, any public or third party
                      infrastructure located on the subject site must be placed within an easement registered
                      against the title of the property.
               30.    All easements must be designed in accordance with the planning scheme and granted at no
                      cost to the Grantee. Where the Grantee is Council or a service authority, the easement
                      documentation must be in accordance with the Grantee’s standard easement terms. Draft
                      easement documentation must be submitted to Council for endorsement.
               31.    All works must be kept clear of any existing or proposed easements on the subject land,
                      unless agreed otherwise in writing by the Grantee.
                      Earthworks and Retaining Walls
               32.    All earthworks and associated retaining structures/batters, both above and below ground,
                      both temporary and permanent, must be undertaken generally in accordance with the
                      conditions of this approval, be generally in accordance with ARCOS’ Earthworks Plan (OPW-
                      C-201, Rev. A) dated 18 December 2023, and be contained entirely within the subject site
                      unless written permission from the respective landowner(s) is provided to Council.
               33.    All retaining walls must be designed and constructed in accordance with the planning scheme
                      and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
                      are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
                      safety fence.




                                                                                                      Page 4 of 13
Document Set ID: 22936245
Version: 3, Version Date: 10/04/2024

Used in these records

About this file

File size
186 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice MCU24 0001 & OPW24 0003.pdf · 186 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.