GENERAL COMMITTEE MEETING MINUTES 12 JULY 2021
5 ITEMS REFERRED FROM COMMITTEES
2 RAP21/0016 APPLICATION FOR A REFERRAL AGENCY RESPONSE FOR A
DWELLING HOUSE (FILLING BEYOND 3M OF THE FOOTPRINT OF BUILDING) AT
11 CHURCH ST, POMONA
Committee Recommendation
Moved: Cr Stockwell
Seconded: Cr Jurisevic
That Council note the report by the Development Planner to the Planning & Environment
Committee Meeting dated 6 July 2021 regarding Application No. RAP21/0016 for a
Referral Agency Response for a Dwelling house (filling beyond 3m of the footprint of
building) situated at 11 Church Street, Pomona and request the assessment manager
(private building certifier) to grant a development approval subject to the following
conditions:
PLANNING
When Conditions must be Complied With
1. Unless otherwise stated, all conditions of this Decision Notice must be complied
with prior to the use commencing, and then compliance maintained at all times
while the use continues.
Approved Plans
2. Development undertaken in accordance with this approval must generally comply
with the approved plans of development. The approved plans are listed in the
following table unless otherwise amended by these conditions.
Plan No. Rev. Plan/Document Name Date
J206156 01A Contour Survey Plan, prepared by Kevin Holt 04/11/2020
Consulting
S4486 NA Site Plan, prepared by Stylemaster 21/01/2021
Sheet 02
S4486 NA Elevations, prepared by Stylemaster 21/01/2021
Sheet 04
S4486 NA Elevations, prepared by Stylemaster 21/01/2021
Sheet 05
Sunset Clause for Referral Agency Response
3. This Referral Agency response is no longer valid if the use has not commenced
within 4 years of the date of this notice, unless otherwise extended in writing by
Council.
Nature and Extent of Approved Use
4. The approved development is limited to the extent of fill proposed on the site. The
proposed dwelling house does not form part of this approval.
Flood Immunity, Drainage and Earthworks
5. All cut and fill must be in accordance with the Approved Plans.
6. Fill material placed over services must not impose any additional surcharge loading
on the service.
7. Excavation must not be carried out within 600mm of any utility infrastructure (to
top, sides and base of services). A retaining wall must be provided to support the
soil surrounding utility infrastructure where proximate to excavation activities.