MCU16/0079 Town Planning Report
Town Planning Report
“Undefined Use”
Staged Extension & Refurbishment of Existing RSL Club
5 Memorial Ave, Tewantin QLD 4565
Lot 3 on T16319 and Lot 10 on SP273411
Erosion and Sediment Control - Guidelines for
Queensland Construction Sites, are used.
Existing Services Code (Division 16)
Table 14-54 Existing Services
column 1 column 2
Compliance
Specific Outcomes Probable solutions (if code assessable)
Setbacks and easements S1.1 The footing of any structure or building is located clear Complies with the Specific Outcome – The site is subject
O1 Development near a sewer, water main, stormwater drain, of the zone of influence but no closer than 1.5m (measured to a sewer line. The development has proposed to upgrade
overland flow path or associated structure does not— horizontally) from infrastructure including sewers, water the sewer line and amend its location. As per Appendix D –
a) adversely affect the function of the service; mains and stormwater structures; AND Sewer and Stormwater Plans, the development is proposed
b) place an additional load on the service; and S1.2 No building or structure overhangs the zone of in close proximity to the existing line.
c) unduly increase future maintenance costs. influence; AND
S1.3 Finished surface levels maintain a minimum of 600mm It is proposed, the development will not impact on the zone of
of cover, but no greater than 3m of cover to the underground influence and will ensure all footings to the building are
infrastructure; AND sufficiently setback. It is proposed to building over the serwe
S1.4 If the existing surface level is altered, surface level line for a port of the line. With the implementation and
services including manholes and inspection points are altered upgrade of the line, it is considered this will not effect the
to match the new surface level; AND performance or life of the line.
S1.5 Alterations are constructed in accordance withPSP6 –
Engineering Design Standards — Water and Sewerage and All earthworks proposed will maintain a 600mm cover over
Section 4 of PSP5 –Engineering Design Standards – Roads, the line at all time.
Drainage and Earthworks; OR
S1.6 Existing services are relocated and the design and The propped upgrade has been designed in accordance with
construction of the relocated services is in accordance with PSP6 and the proposed development is not considered to
PSP6 –Engineering Design Standards — Water and place an addition load on the services provided.
Sewerage and Section 4 of PSP5 –Engineering Design
Standards – Roads, Drainage and Earthworks Overall it is considered the proposed upgrade and
development maintain the services provided for the area.